A&D AD-4405 manual Rear Panel Description, Other Displays and Symbols

Page 11

 

ZERO key

The key to zero the current display.

 

CLEAR key

The key to clear the setting value.

 

TARE key

The key to perform tare.

 

ESC key

The key to proceed to the next step without changing the

 

parameter set.

 

 

 

NET/GROSS key

The key to select net or gross weight in the display.

 

+/- key

The key to select + or – of a value.

 

ENTER key

Confirms settings and stores the value.

 

PRINT key

The key to print/output data (press and release quickly).

 

ON/OFF key

Turns the indicator on and off (OFF: hold for 3 seconds).

10

Printer cover

Printing paper will be stored inside when the printer is installed.

 

Printer

Internal dot matrix printer (optional).

4.1.2.Rear Panel Description

12

13

14

15

11

16

No.

Name

Description

11

Power cable

Please confirm that the local voltage and receptacle type are

correct for your scale.

 

 

12

Grounding terminal

Connect to the Earth (M4 size screw).

13

Load cell connector

Connect a load cell using the accessory load cell plug.

14

CAL switch cover

The CAL switch is located behind the sealing panel [15].

15

Sealing panel

For type approval, available with the sealing wire posts.

16

RS-232C connector

Exchange this when installing other data output (options).

4.1.3.Other Displays and Symbols

Standby display.

Zero error when turning the display on. If the ESC key is pressed, the current weighing value may should be displayed.

Over load display. Remove any load from the load cell immediately. It may cause damage to the load cell.

An example of an error display.

AD-4405 Weighing Indicator

Page 9

4. Description of Panels and symbols

Image 11
Contents Weighing Indicator This manual and Marks Contents Setting the Parameters of Setpoint Comparison Compliance with European Directives ComplianceCompliance with FCC Rules Introduction Load Cell Connections Installation and PrecautionsInstallation and Precautions Verifying Load Cell Output and Input Sensitivity Adjustment of the Load Cell OutputInstalling an Option Board Front Panel Description Description of Panels and symbolsRear Panel Description Other Displays and SymbolsOptions Accessories and optionsStandard accessories Supplemental accessories for printerCalibration Items of Calibration ModeConfiguring a Weighing Instrument Calibration ProcedureSpecifying the Range and Unit Specifying the Resolution, Decimal Point Position and FormatSpecifying the Second Range Capacity Specifying the Second Range ResolutionTo Get Stabilized Data Specifying the Weighing Range of the First RangeSpan Calibration Zero CalibrationExiting the Calibration Mode Weighing Range Function Digital Linearization Function Setting the Division and RangeGravity Compensation Function Gravity Acceleration Table Calibration Error Code List Functions Changing the Function SettingsOFF FunctionsZERO+TARE = CAL EXT3 EXT1EXT2 Comparator Data Output Current Loop Output Serial Interface DD/MM/YY YY/MM/DD MM/DD/YYPrint Format CF-Functions Clearing Tare Digital Input Preset TareTare Weighing TareAccumulation Preparation and SpecificationsDisplay and Operation Parameter Code Memory Using Code MemoryComparison Weight Check ModeLO, OK Condition formula for ComparisonHI, OK Mode Setting the Upper/Lower Limit ValuesSetting Order and Display for Weight Check Mode Output and Condition Setpoint ComparisonDescription of Input parameters and Outputs F22 = 7 Check weighingWeighing Completion F22 = 9 Check weighing 3Loss in weightSimple Batch StartReturns to Zero band Setting the Parameters of Setpoint ComparisonToward the Zero band Relations to the Other Functions Setting the Hold FunctionsHold Function Display and the Data Output of Hold and AverageMT, MZ, HC Key input and command in the hold stateConditions of the Average and Release TARE, ZERO, SETPOINT, TotalCounting Function Using the Counting FunctionUnit Weight Registration Key to register the unit weight and return to the piece YY/MM/DD Calendar / Clock13.1 Time and Date Functions Setting Time and Date Corrected date is as follows 05 05 Internal Printer OP-06 Replacing the Ink Ribbon Installing the Printer Paper Special roll paperCommon Printer and Data Output Items 15.1 Data Output / Print ModeInterval Data Output / Print Data NumberInterval Data Output / Print output Setting the Interval TimeBit Format 16.1 SpecificationsRS-232C Interface Circuit and Pin ConnectionFigures Data FormatExplanation of Commands Command FormatCommands to Request Data Commands to Control the Indicator Changing the Code Memory Changing the Weight UnitSet the Limit/Setpoint Value Commands to Set ParametersSet the Preset Tare Set the Unit Weight for Counting ModeRelease the Hold Data Commands for the Hold FunctionCommands to Set the Data Output/ Print Format UFC Start Averaging to HoldUFC Command Parameters UFC CommandsPF2,$DT$TM$LF$AN$SP$TL$LF $DLSF1,$ID$DN$CR$LF$GR$UT$CR$LF ’$AN$TL$LF$LFCircuit RS-422/RS-485, Relay OutputOP-03TRM COMSwitching Between RS-422/RS-485 Circuits Relay Output & Control Input OP-05DC50V 19 -20mA Analog Output OP-07 SpecificationsSettings CL2 Current Loop Output OP-08CL1 Data Format Current Loop OutputInterface SpecificationsAnalog Input and A/D Conversion Digital SectionGeneral DimensionsMemo Memo Memo