A&D AD-4405 manual Weighing Indicator

Page 1

Weighing Indicator

WM+PD4000504

Image 1
Contents Weighing Indicator This manual and Marks Contents Setting the Parameters of Setpoint Comparison Compliance with FCC Rules ComplianceCompliance with European Directives Introduction Installation and Precautions Installation and PrecautionsLoad Cell Connections Verifying Load Cell Output and Input Sensitivity Adjustment of the Load Cell OutputInstalling an Option Board Front Panel Description Description of Panels and symbolsRear Panel Description Other Displays and SymbolsStandard accessories Accessories and optionsSupplemental accessories for printer OptionsCalibration Items of Calibration ModeConfiguring a Weighing Instrument Calibration ProcedureSpecifying the Range and Unit Specifying the Resolution, Decimal Point Position and FormatTo Get Stabilized Data Specifying the Second Range ResolutionSpecifying the Weighing Range of the First Range Specifying the Second Range CapacitySpan Calibration Zero CalibrationExiting the Calibration Mode Weighing Range Function Digital Linearization Function Setting the Division and RangeGravity Compensation Function Gravity Acceleration Table Calibration Error Code List Functions Changing the Function SettingsOFF FunctionsZERO+TARE = CAL EXT2 EXT1EXT3 Comparator Data Output Current Loop Output Serial Interface DD/MM/YY YY/MM/DD MM/DD/YYPrint Format CF-Functions Tare Digital Input Preset TareWeighing Tare Clearing TareAccumulation Preparation and SpecificationsDisplay and Operation Parameter Code Memory Using Code MemoryComparison Weight Check ModeHI, OK Condition formula for ComparisonLO, OK Setting Order and Display for Weight Check Mode Setting the Upper/Lower Limit ValuesMode Description of Input parameters and Outputs Setpoint ComparisonF22 = 7 Check weighing Output and ConditionSimple Batch F22 = 9 Check weighing 3Loss in weightStart Weighing CompletionToward the Zero band Setting the Parameters of Setpoint ComparisonReturns to Zero band Hold Function Setting the Hold FunctionsDisplay and the Data Output of Hold and Average Relations to the Other FunctionsConditions of the Average and Release Key input and command in the hold stateTARE, ZERO, SETPOINT, Total MT, MZ, HCUnit Weight Registration Using the Counting FunctionCounting Function Key to register the unit weight and return to the piece 13.1 Time and Date Functions Calendar / ClockYY/MM/DD Setting Time and Date Corrected date is as follows 05 05 Internal Printer OP-06 Replacing the Ink Ribbon Installing the Printer Paper Special roll paperCommon Printer and Data Output Items 15.1 Data Output / Print ModeInterval Data Output / Print Data NumberInterval Data Output / Print output Setting the Interval TimeRS-232C Interface 16.1 SpecificationsCircuit and Pin Connection Bit FormatFigures Data FormatExplanation of Commands Command FormatCommands to Request Data Commands to Control the Indicator Changing the Code Memory Changing the Weight UnitSet the Preset Tare Commands to Set ParametersSet the Unit Weight for Counting Mode Set the Limit/Setpoint ValueCommands to Set the Data Output/ Print Format UFC Commands for the Hold FunctionStart Averaging to Hold Release the Hold DataUFC Command Parameters UFC CommandsSF1,$ID$DN$CR$LF$GR$UT$CR$LF $DL’$AN$TL$LF$LF PF2,$DT$TM$LF$AN$SP$TL$LFTRM RS-422/RS-485, Relay OutputOP-03COM CircuitSwitching Between RS-422/RS-485 DC50V Relay Output & Control Input OP-05Circuits Settings Specifications19 -20mA Analog Output OP-07 CL1 Current Loop Output OP-08CL2 Data Format Current Loop OutputAnalog Input and A/D Conversion SpecificationsDigital Section InterfaceGeneral DimensionsMemo Memo Memo