A&D AD-4405 manual Current Loop Output OP-08, CL1, CL2

Page 72

20. Current Loop Output (OP-08)

Replacing the RS-232C interface with this option, current loop output, 3-relay outputs and 1-control input can be used with the RS-232C interface of this option.

RS-232C functions and pin connections are the same as the RS-232C interface described in “16. RS-232C Interface”.

The control input can control the indicator from an external terminal just like the front panel key operations.

Set the external control function at f15 of the F-Functions.

When connecting the function pin and the common pin, the indicator makes the action. Keep a signal width of more than 100 ms for the On-time and Off-time.

ON(Make)

 

More than 100 ms

More than 100 ms

OFF(Break)

 

 

 

The relays output the result of comparison.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Solid-state-relay

 

 

 

 

 

 

 

Maximum voltage

DC50V

 

 

 

 

 

Maximum current

DC100mA

 

 

 

 

 

Maximum resistance 89

 

 

 

 

Pin connections (DIN 8pin connector)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Function

Pin No.

 

Signal name

Direction

Description

 

 

 

 

1

 

HI

Output

Relay output HI

 

 

 

Relay

6

 

OK

Output

Relay output OK

 

 

 

output

4

 

LO

Output

Relay output LO

 

 

 

 

8

 

COM(out)

-

Relay common terminal

 

 

 

Current

3

 

CL1

Output

Current loop output 1

 

 

 

loop

5

 

CL2

Output

Current loop output 2

 

 

 

Control

7

 

EXT3

Input

Control input 3 (f15)

 

 

 

input

2

 

COM(in)

-

Control input common

 

 

Adaptable connector

JA-TCP0586 (of accessory)

 

 

 

 

Circuits

Control input

 

 

Relay output

+7 to 9V

 

 

COM(out)

 

 

 

 

EXT3

 

OK

6809

 

 

Current loop output

 

 

 

￿

￿

 

HI

 

 

COM

LO

￿

￿

DIN connector

 

 

(in) K

of OP-08

 

 

 

20. Current Loop Output (OP-08)

Page 70

AD-4405 Weighing Indicator

Image 72
Contents Weighing Indicator This manual and Marks Contents Setting the Parameters of Setpoint Comparison Compliance Compliance with FCC RulesCompliance with European Directives Introduction Installation and Precautions Installation and PrecautionsLoad Cell Connections Adjustment of the Load Cell Output Verifying Load Cell Output and Input SensitivityInstalling an Option Board Description of Panels and symbols Front Panel DescriptionOther Displays and Symbols Rear Panel DescriptionAccessories and options Standard accessoriesSupplemental accessories for printer OptionsItems of Calibration Mode CalibrationCalibration Procedure Configuring a Weighing InstrumentSpecifying the Resolution, Decimal Point Position and Format Specifying the Range and UnitSpecifying the Second Range Resolution To Get Stabilized DataSpecifying the Weighing Range of the First Range Specifying the Second Range CapacityZero Calibration Span CalibrationExiting the Calibration Mode Weighing Range Function Setting the Division and Range Digital Linearization FunctionGravity Compensation Function Gravity Acceleration Table Calibration Error Code List Changing the Function Settings FunctionsFunctions OFFZERO+TARE = CAL EXT1 EXT2EXT3 Comparator Data Output Current Loop Output Serial Interface YY/MM/DD MM/DD/YY DD/MM/YYPrint Format CF-Functions Digital Input Preset Tare TareWeighing Tare Clearing TarePreparation and Specifications AccumulationDisplay and Operation Parameter Using Code Memory Code MemoryWeight Check Mode ComparisonCondition formula for Comparison HI, OKLO, OK Setting the Upper/Lower Limit Values Setting Order and Display for Weight Check ModeMode Setpoint Comparison Description of Input parameters and OutputsF22 = 7 Check weighing Output and ConditionF22 = 9 Check weighing 3Loss in weight Simple BatchStart Weighing CompletionSetting the Parameters of Setpoint Comparison Toward the Zero bandReturns to Zero band Setting the Hold Functions Hold FunctionDisplay and the Data Output of Hold and Average Relations to the Other FunctionsKey input and command in the hold state Conditions of the Average and ReleaseTARE, ZERO, SETPOINT, Total MT, MZ, HCUsing the Counting Function Unit Weight RegistrationCounting Function Key to register the unit weight and return to the piece Calendar / Clock 13.1 Time and Date FunctionsYY/MM/DD Setting Time and Date Corrected date is as follows 05 05 Internal Printer OP-06 Installing the Printer Paper Special roll paper Replacing the Ink Ribbon15.1 Data Output / Print Mode Common Printer and Data Output ItemsData Number Interval Data Output / PrintSetting the Interval Time Interval Data Output / Print output16.1 Specifications RS-232C InterfaceCircuit and Pin Connection Bit FormatData Format FiguresCommand Format Explanation of CommandsCommands to Request Data Commands to Control the Indicator Changing the Weight Unit Changing the Code MemoryCommands to Set Parameters Set the Preset TareSet the Unit Weight for Counting Mode Set the Limit/Setpoint ValueCommands for the Hold Function Commands to Set the Data Output/ Print Format UFCStart Averaging to Hold Release the Hold DataUFC Commands UFC Command Parameters$DL SF1,$ID$DN$CR$LF$GR$UT$CR$LF’$AN$TL$LF$LF PF2,$DT$TM$LF$AN$SP$TL$LFRS-422/RS-485, Relay OutputOP-03 TRMCOM CircuitSwitching Between RS-422/RS-485 Relay Output & Control Input OP-05 DC50VCircuits Specifications Settings19 -20mA Analog Output OP-07 Current Loop Output OP-08 CL1CL2 Current Loop Output Data FormatSpecifications Analog Input and A/D ConversionDigital Section InterfaceDimensions GeneralMemo Memo Memo