A&D AD-4405 manual Serial Interface

Page 31

Serial Interface

Item

Parameter

 

Description

 

 

** 0

Stream mode, command is not acceptable

 

 

1

Manual mode, command is effective

 

f40

2

Auto print mode(+), command is effective

 

Output mode

3

Auto print mode(+/-), command is effective

 

 

4

When accumulation, automatically output

 

 

5

Command mode (output by command only)

 

 

0

No output

 

 

 

 

f41

** 1

Manual, Fixed format

 

 

 

Accumulated data

2

Auto, Fixed format

 

 

 

output at

3

Manual, Format 1 (f34)

 

 

 

accumulated data

4

Auto, Format 1 (f34)

 

 

 

display

5

Manual, Format 2 (f35)

 

 

 

 

6

Auto, Format 2 (f35)

 

 

 

 

** 0

No delay

 

 

 

 

f42

1

0.5 second

 

 

 

 

2

1.0 second

 

 

 

 

Delay for continual data

 

 

 

 

3

1.5 seconds

 

 

 

 

 

 

 

 

 

 

4

2.0 seconds

 

 

 

 

f43

** 0

Not used

 

 

 

 

Command address

1

Use (Address determined f06)

 

f44

** 0

Approx. 1 second

 

 

 

Time out

1

No limitation

 

 

 

 

f45

** 0

CR, LF (0Dh, 0Ah)

 

 

 

Terminator

1

CR (0Dh)

 

 

 

 

f46

 

S. I/F and Internal Printer

Current Loop output

 

D.P.

Delimitter

D.P.

 

Delimitter

D.P. / DelimitterSerial

 

 

* 0

Dot (.)

Comma (,)

Dot (.)

 

Comma (,)

Interface, Internal

 

1

Comma (,)

Semicolon (;)

Dot (.)

 

Comma (,)

Printer and Current

 

2

Dot (.)

Comma (,)

Comma (,)

 

Semicolon (;)

Loop output

 

3

Comma (,)

Semicolon (;)

Comma (,)

 

Semicolon (;)

 

 

 

0

600 bps

 

 

 

 

f47

1

1200 bps

 

 

 

 

** 2

2400 bps

 

 

 

 

Baud rate

 

 

 

 

3

4800 bps

 

 

 

 

 

 

 

 

 

 

4

9600 bps

 

 

 

 

f48

** 0

Data 7bits, Even parity

 

 

 

1

Data 7bits, Odd parity

 

 

 

Data bit, parity

 

 

 

2

Data 8bits, Non parity

 

 

 

 

 

 

 

*: Initial settings.

bps: bit per second.

 

 

 

AD-4405 Weighing Indicator

Page 29

6.2. F-Functions

Image 31
Contents Weighing Indicator This manual and Marks Contents Setting the Parameters of Setpoint Comparison Compliance with FCC Rules ComplianceCompliance with European Directives Introduction Installation and Precautions Installation and PrecautionsLoad Cell Connections Verifying Load Cell Output and Input Sensitivity Adjustment of the Load Cell OutputInstalling an Option Board Front Panel Description Description of Panels and symbolsRear Panel Description Other Displays and SymbolsOptions Accessories and optionsStandard accessories Supplemental accessories for printerCalibration Items of Calibration ModeConfiguring a Weighing Instrument Calibration ProcedureSpecifying the Range and Unit Specifying the Resolution, Decimal Point Position and FormatSpecifying the Second Range Capacity Specifying the Second Range ResolutionTo Get Stabilized Data Specifying the Weighing Range of the First RangeSpan Calibration Zero CalibrationExiting the Calibration Mode Weighing Range Function Digital Linearization Function Setting the Division and RangeGravity Compensation Function Gravity Acceleration Table Calibration Error Code List Functions Changing the Function SettingsOFF FunctionsZERO+TARE = CAL EXT2 EXT1EXT3 Comparator Data Output Current Loop Output Serial Interface DD/MM/YY YY/MM/DD MM/DD/YYPrint Format CF-Functions Clearing Tare Digital Input Preset TareTare Weighing TareAccumulation Preparation and SpecificationsDisplay and Operation Parameter Code Memory Using Code MemoryComparison Weight Check ModeHI, OK Condition formula for ComparisonLO, OK Setting Order and Display for Weight Check Mode Setting the Upper/Lower Limit ValuesMode Output and Condition Setpoint ComparisonDescription of Input parameters and Outputs F22 = 7 Check weighingWeighing Completion F22 = 9 Check weighing 3Loss in weightSimple Batch StartToward the Zero band Setting the Parameters of Setpoint ComparisonReturns to Zero band Relations to the Other Functions Setting the Hold FunctionsHold Function Display and the Data Output of Hold and AverageMT, MZ, HC Key input and command in the hold stateConditions of the Average and Release TARE, ZERO, SETPOINT, TotalUnit Weight Registration Using the Counting FunctionCounting Function Key to register the unit weight and return to the piece 13.1 Time and Date Functions Calendar / ClockYY/MM/DD Setting Time and Date Corrected date is as follows 05 05 Internal Printer OP-06 Replacing the Ink Ribbon Installing the Printer Paper Special roll paperCommon Printer and Data Output Items 15.1 Data Output / Print ModeInterval Data Output / Print Data NumberInterval Data Output / Print output Setting the Interval TimeBit Format 16.1 SpecificationsRS-232C Interface Circuit and Pin ConnectionFigures Data FormatExplanation of Commands Command FormatCommands to Request Data Commands to Control the Indicator Changing the Code Memory Changing the Weight UnitSet the Limit/Setpoint Value Commands to Set ParametersSet the Preset Tare Set the Unit Weight for Counting ModeRelease the Hold Data Commands for the Hold FunctionCommands to Set the Data Output/ Print Format UFC Start Averaging to HoldUFC Command Parameters UFC CommandsPF2,$DT$TM$LF$AN$SP$TL$LF $DLSF1,$ID$DN$CR$LF$GR$UT$CR$LF ’$AN$TL$LF$LFCircuit RS-422/RS-485, Relay OutputOP-03TRM COMSwitching Between RS-422/RS-485 DC50V Relay Output & Control Input OP-05Circuits Settings Specifications19 -20mA Analog Output OP-07 CL1 Current Loop Output OP-08CL2 Data Format Current Loop OutputInterface SpecificationsAnalog Input and A/D Conversion Digital SectionGeneral DimensionsMemo Memo Memo