A&D AD-4405 manual Key to register the unit weight and return to the piece

Page 49

ENTER

key

The key to register the unit weight and return to the piece

 

 

 

count display. The unit weight is calculated automatically

 

 

 

with the weight and the number of samples.

 

 

 

Press the

ESC

key while pressing +/- key

 

 

 

The key to return to the piece count display without changing

 

 

 

the unit weight.

Notes

 

 

It is preferable to have a large number of samples, to minimize the

 

 

 

 

 

 

 

counting error.

 

 

 

 

 

 

 

 

 

Press the

ENTER

key after the STABLE mark turns on.

 

 

 

 

 

 

If the total weight of the samples is too light and is not adequate to be used as the unit weight, loUt is displayed for 2 seconds and returns to the registration display.

Digital input

When the unit weight is already known, digital input is available.

Step 1

Start with the normal weight mode.

 

 

 

 

 

 

Step 2

Press the

SAMPLE

key to enter the digital input of the unit the weight.

U xxx

and

the weight unit is displayed with unit pcs blinking. Using following keys:

0 - 9 key

The key to set the unit weight. Maximum is 5 digits.

+/- key

The key to select the weighing unit of the unit weight.

 

 

 

 

 

 

 

ZERO

................key

The key to clear the digital input.

U----

is displayed.

 

 

 

The key to return to the normal weight display without

ESC

..................key

 

 

 

 

changing the registered unit weight.

 

 

The key to register the unit weight and return to the normal

ENTER

..............key

weight display.

Press the MODE key while pressing the +/- key The key to shift the decimal point.

AD-4405 Weighing Indicator

Page 47

12. Counting Function

Image 49
Contents Weighing Indicator This manual and Marks Contents Setting the Parameters of Setpoint Comparison Compliance with FCC Rules ComplianceCompliance with European Directives Introduction Installation and Precautions Installation and PrecautionsLoad Cell Connections Verifying Load Cell Output and Input Sensitivity Adjustment of the Load Cell OutputInstalling an Option Board Front Panel Description Description of Panels and symbolsRear Panel Description Other Displays and SymbolsStandard accessories Accessories and optionsSupplemental accessories for printer OptionsCalibration Items of Calibration ModeConfiguring a Weighing Instrument Calibration ProcedureSpecifying the Range and Unit Specifying the Resolution, Decimal Point Position and FormatTo Get Stabilized Data Specifying the Second Range ResolutionSpecifying the Weighing Range of the First Range Specifying the Second Range CapacitySpan Calibration Zero CalibrationExiting the Calibration Mode Weighing Range Function Digital Linearization Function Setting the Division and RangeGravity Compensation Function Gravity Acceleration Table Calibration Error Code List Functions Changing the Function SettingsOFF FunctionsZERO+TARE = CAL EXT2 EXT1EXT3 Comparator Data Output Current Loop Output Serial Interface DD/MM/YY YY/MM/DD MM/DD/YYPrint Format CF-Functions Tare Digital Input Preset TareWeighing Tare Clearing TareAccumulation Preparation and SpecificationsDisplay and Operation Parameter Code Memory Using Code MemoryComparison Weight Check ModeHI, OK Condition formula for ComparisonLO, OK Setting Order and Display for Weight Check Mode Setting the Upper/Lower Limit ValuesMode Description of Input parameters and Outputs Setpoint ComparisonF22 = 7 Check weighing Output and ConditionSimple Batch F22 = 9 Check weighing 3Loss in weightStart Weighing CompletionToward the Zero band Setting the Parameters of Setpoint ComparisonReturns to Zero band Hold Function Setting the Hold FunctionsDisplay and the Data Output of Hold and Average Relations to the Other FunctionsConditions of the Average and Release Key input and command in the hold stateTARE, ZERO, SETPOINT, Total MT, MZ, HCUnit Weight Registration Using the Counting FunctionCounting Function Key to register the unit weight and return to the piece 13.1 Time and Date Functions Calendar / ClockYY/MM/DD Setting Time and Date Corrected date is as follows 05 05 Internal Printer OP-06 Replacing the Ink Ribbon Installing the Printer Paper Special roll paperCommon Printer and Data Output Items 15.1 Data Output / Print ModeInterval Data Output / Print Data NumberInterval Data Output / Print output Setting the Interval TimeRS-232C Interface 16.1 SpecificationsCircuit and Pin Connection Bit FormatFigures Data FormatExplanation of Commands Command FormatCommands to Request Data Commands to Control the Indicator Changing the Code Memory Changing the Weight UnitSet the Preset Tare Commands to Set ParametersSet the Unit Weight for Counting Mode Set the Limit/Setpoint ValueCommands to Set the Data Output/ Print Format UFC Commands for the Hold FunctionStart Averaging to Hold Release the Hold DataUFC Command Parameters UFC CommandsSF1,$ID$DN$CR$LF$GR$UT$CR$LF $DL’$AN$TL$LF$LF PF2,$DT$TM$LF$AN$SP$TL$LFTRM RS-422/RS-485, Relay OutputOP-03COM CircuitSwitching Between RS-422/RS-485 DC50V Relay Output & Control Input OP-05Circuits Settings Specifications19 -20mA Analog Output OP-07 CL1 Current Loop Output OP-08CL2 Data Format Current Loop OutputAnalog Input and A/D Conversion SpecificationsDigital Section InterfaceGeneral DimensionsMemo Memo Memo