External Input

 

Item

 

Parameter

 

 

 

Description

 

 

 

** 0

Not used (No function)

 

 

 

 

 

 

1

ZERO key

 

 

 

 

 

 

 

2

TARE key

 

 

 

 

 

 

 

3

NET/GROSS key

 

 

 

 

 

 

4

ON/OFF key

 

 

 

 

 

 

5

PRINT key, ENTER key

 

 

 

 

 

 

6

FEED key

 

 

 

 

 

 

 

7

Serial data output (Format 1)

 

 

 

 

 

8

Serial data output (Format 2)

 

 

f13

 

 

9

Accumulation (M+)

 

 

 

EXT1

 

 

10

Start batching

 

 

 

Function selection of

 

11

Stop batching

 

 

 

external input

 

12

“Over” signal, Gross over and display data out when ON

 

 

 

13

NET weight display when shorting the terminal.

 

 

 

14

Accumulated data display when shorting the terminal.

 

 

 

15

Execute comparison when shorting the terminal.

 

 

 

16

Display by the second unit when shorting the terminal.

 

 

 

17

All keys are enabled when shorting the terminal.

 

 

 

 

(Ignores F12 setting temporary)

 

 

 

18

Inhibit memory code reading when shorting the terminal.

 

 

 

19

Start averaging to hold

 

 

 

 

 

 

20

Release holding data

 

 

 

f14

 

 

0 to 17, 19 and 20

Same as f13

 

 

 

EXT2

 

 

18

Code Memory (BCD 1)

 

 

 

f15

 

 

0 to 17, 19 and 20

Same as f13

 

 

 

EXT3

 

 

18

Cord Memory (BCD 2)

 

 

 

*:

Initial settings.

 

 

 

 

 

 

 

 

Accumulation

 

 

 

 

 

 

 

 

 

Item

 

Parameter

 

 

 

Description

 

 

 

10 11

Acc. no (0) / Exec (1)

Left: Sub item, select using the

 

 

 

 

 

 

 

 

 

ZERO

key

f20

[Type2]

 

20 21

Manual (0) / Auto (1)

 

 

Right: Setting, select using the

Accumulation Mode

 

30 31

+ Only (0) / +/- (1)

 

 

0 , 1 keys

 

 

 

 

 

 

 

 

 

 

 

 

40 41

OK only (0) /All data (1)

 

 

 

 

Initial settings: 10, 21, 31, 41

 

 

 

0

Add data anytime

The selection of the inhibit region

f21

 

 

** 1

Above

 

5 d

 

 

 

for accumulation.

 

 

 

Inhibit region for

 

2

Above

 

10 d

 

 

Do not set f21 0 when Auto

accumulation

 

 

 

 

 

 

 

3

Above

 

20 d

 

 

accumulation (f20 21).

 

 

 

 

 

 

 

 

 

 

 

4

Above

 

50 d

 

 

 

 

 

 

 

 

 

 

 

 

 

 

d: division (weighing interval) of first range.

*:

Initial settings.

AD-4405 Weighing Indicator

Page 25

6.2. F-Functions

Image 27
Contents Weighing Indicator This manual and Marks Contents Setting the Parameters of Setpoint Comparison Compliance Compliance with FCC RulesCompliance with European Directives Introduction Installation and Precautions Installation and PrecautionsLoad Cell Connections Verifying Load Cell Output and Input Sensitivity Adjustment of the Load Cell OutputInstalling an Option Board Front Panel Description Description of Panels and symbolsRear Panel Description Other Displays and SymbolsOptions Accessories and optionsStandard accessories Supplemental accessories for printerCalibration Items of Calibration ModeConfiguring a Weighing Instrument Calibration ProcedureSpecifying the Range and Unit Specifying the Resolution, Decimal Point Position and FormatSpecifying the Second Range Capacity Specifying the Second Range ResolutionTo Get Stabilized Data Specifying the Weighing Range of the First RangeSpan Calibration Zero CalibrationExiting the Calibration Mode Weighing Range Function Digital Linearization Function Setting the Division and RangeGravity Compensation Function Gravity Acceleration Table Calibration Error Code List Functions Changing the Function SettingsOFF FunctionsZERO+TARE = CAL EXT1 EXT2EXT3 Comparator Data Output Current Loop Output Serial Interface DD/MM/YY YY/MM/DD MM/DD/YYPrint Format CF-Functions Clearing Tare Digital Input Preset TareTare Weighing TareAccumulation Preparation and SpecificationsDisplay and Operation Parameter Code Memory Using Code MemoryComparison Weight Check ModeCondition formula for Comparison HI, OKLO, OK Setting the Upper/Lower Limit Values Setting Order and Display for Weight Check ModeMode Output and Condition Setpoint ComparisonDescription of Input parameters and Outputs F22 = 7 Check weighingWeighing Completion F22 = 9 Check weighing 3Loss in weightSimple Batch StartSetting the Parameters of Setpoint Comparison Toward the Zero bandReturns to Zero band Relations to the Other Functions Setting the Hold FunctionsHold Function Display and the Data Output of Hold and AverageMT, MZ, HC Key input and command in the hold stateConditions of the Average and Release TARE, ZERO, SETPOINT, TotalUsing the Counting Function Unit Weight RegistrationCounting Function Key to register the unit weight and return to the piece Calendar / Clock 13.1 Time and Date FunctionsYY/MM/DD Setting Time and Date Corrected date is as follows 05 05 Internal Printer OP-06 Replacing the Ink Ribbon Installing the Printer Paper Special roll paperCommon Printer and Data Output Items 15.1 Data Output / Print ModeInterval Data Output / Print Data NumberInterval Data Output / Print output Setting the Interval TimeBit Format 16.1 SpecificationsRS-232C Interface Circuit and Pin ConnectionFigures Data FormatExplanation of Commands Command FormatCommands to Request Data Commands to Control the Indicator Changing the Code Memory Changing the Weight UnitSet the Limit/Setpoint Value Commands to Set ParametersSet the Preset Tare Set the Unit Weight for Counting ModeRelease the Hold Data Commands for the Hold FunctionCommands to Set the Data Output/ Print Format UFC Start Averaging to HoldUFC Command Parameters UFC CommandsPF2,$DT$TM$LF$AN$SP$TL$LF $DLSF1,$ID$DN$CR$LF$GR$UT$CR$LF ’$AN$TL$LF$LFCircuit RS-422/RS-485, Relay OutputOP-03TRM COMSwitching Between RS-422/RS-485 Relay Output & Control Input OP-05 DC50VCircuits Specifications Settings19 -20mA Analog Output OP-07 Current Loop Output OP-08 CL1CL2 Data Format Current Loop OutputInterface SpecificationsAnalog Input and A/D Conversion Digital SectionGeneral DimensionsMemo Memo Memo