A&D AD-4405 Simple Batch, F22 = 9 Check weighing 3Loss in weight, Start, Weighing Completion

Page 44

F22 = 9 (Check weighing 3:Loss in weight)

Weighing value

Tared Zero

Preset target weight

 

 

 

 

Final

Tare

 

Weighing

 

 

Free fall

 

 

 

Zero band

Calibrated Zero

 

 

Output and Condition

 

Time

 

 

Relay HI,

1, -Net ] - (Final - Free fall)

 

OFF

 

 

ON

OFF

Relay LO,

3, Gross ¢ Zero band

ON

 

OFF

 

 

ON

 

OFF

 

 

 

 

 

 

 

 

 

 

 

Relay OK*,

2, Gross ] Full

OFF

 

ON

 

OFF

 

 

ON

 

 

 

 

 

 

 

 

 

 

 

*Relay OK output can be changed to OVER or UNDER by setting f24. Triangle 2 is displayed when Gross ] Full regardless of the f24 setting.

OVER/UNDER is judged always and the result is output to the LED and the relay.

10.2.2.Simple Batch

The weighing sequences of simple batch (f22 10,11 or 12) are similar to those of Check weighing (f22 7, 8 or 9) respectively. The differences are listed below.

1

Basically ON/OFF of the relay and the LED are reversed.

2

No judgment other than Zero band and Full before input of the Start signal.

3

The weighing completion condition is set by f23 2x and it is effective after Start.

4The outputs of Preliminary and Free fall are off from weighing completion to the next start.

5 Weighing completion can be output by setting f24 and f25.

6The start signal can be accepted after weighing completion even if the weight is not within the zero band.

7 Over/Under output is set by f23 3x.

Start

Tare, when the Start is input automatically if f23 11.

The READY mark turns off when the Start is input.

Weighing Completion

The weighing completion condition is set by f23 2x.

f23 20 : Either the STOP key is pressed or the Batch stop input is on.

f23 21 : Stable is detected after reaching Final.

Before reaching Final, the STOP key or Batch stop input forces weighing completion even if f23 21.

10.2. Setpoint Comparison

Page 42

AD-4405 Weighing Indicator

Image 44
Contents Weighing Indicator This manual and Marks Contents Setting the Parameters of Setpoint Comparison Compliance with European Directives ComplianceCompliance with FCC Rules Introduction Load Cell Connections Installation and PrecautionsInstallation and Precautions Adjustment of the Load Cell Output Verifying Load Cell Output and Input SensitivityInstalling an Option Board Description of Panels and symbols Front Panel DescriptionOther Displays and Symbols Rear Panel DescriptionAccessories and options Standard accessoriesSupplemental accessories for printer OptionsItems of Calibration Mode CalibrationCalibration Procedure Configuring a Weighing InstrumentSpecifying the Resolution, Decimal Point Position and Format Specifying the Range and UnitSpecifying the Second Range Resolution To Get Stabilized DataSpecifying the Weighing Range of the First Range Specifying the Second Range CapacityZero Calibration Span CalibrationExiting the Calibration Mode Weighing Range Function Setting the Division and Range Digital Linearization FunctionGravity Compensation Function Gravity Acceleration Table Calibration Error Code List Changing the Function Settings FunctionsFunctions OFFZERO+TARE = CAL EXT3 EXT1EXT2 Comparator Data Output Current Loop Output Serial Interface YY/MM/DD MM/DD/YY DD/MM/YYPrint Format CF-Functions Digital Input Preset Tare TareWeighing Tare Clearing TarePreparation and Specifications AccumulationDisplay and Operation Parameter Using Code Memory Code MemoryWeight Check Mode ComparisonLO, OK Condition formula for ComparisonHI, OK Mode Setting the Upper/Lower Limit ValuesSetting Order and Display for Weight Check Mode Setpoint Comparison Description of Input parameters and OutputsF22 = 7 Check weighing Output and ConditionF22 = 9 Check weighing 3Loss in weight Simple BatchStart Weighing CompletionReturns to Zero band Setting the Parameters of Setpoint ComparisonToward the Zero band Setting the Hold Functions Hold FunctionDisplay and the Data Output of Hold and Average Relations to the Other FunctionsKey input and command in the hold state Conditions of the Average and ReleaseTARE, ZERO, SETPOINT, Total MT, MZ, HCCounting Function Using the Counting FunctionUnit Weight Registration Key to register the unit weight and return to the piece YY/MM/DD Calendar / Clock13.1 Time and Date Functions Setting Time and Date Corrected date is as follows 05 05 Internal Printer OP-06 Installing the Printer Paper Special roll paper Replacing the Ink Ribbon15.1 Data Output / Print Mode Common Printer and Data Output ItemsData Number Interval Data Output / PrintSetting the Interval Time Interval Data Output / Print output16.1 Specifications RS-232C InterfaceCircuit and Pin Connection Bit FormatData Format FiguresCommand Format Explanation of CommandsCommands to Request Data Commands to Control the Indicator Changing the Weight Unit Changing the Code MemoryCommands to Set Parameters Set the Preset TareSet the Unit Weight for Counting Mode Set the Limit/Setpoint ValueCommands for the Hold Function Commands to Set the Data Output/ Print Format UFCStart Averaging to Hold Release the Hold DataUFC Commands UFC Command Parameters$DL SF1,$ID$DN$CR$LF$GR$UT$CR$LF’$AN$TL$LF$LF PF2,$DT$TM$LF$AN$SP$TL$LFRS-422/RS-485, Relay OutputOP-03 TRMCOM CircuitSwitching Between RS-422/RS-485 Circuits Relay Output & Control Input OP-05DC50V 19 -20mA Analog Output OP-07 SpecificationsSettings CL2 Current Loop Output OP-08CL1 Current Loop Output Data FormatSpecifications Analog Input and A/D ConversionDigital Section InterfaceDimensions GeneralMemo Memo Memo