A&D AD-4405 manual Current Loop Output

Page 30

Current Loop Output

Item

Parameter

Description

 

** 0

Displayed data

f36

1

Gross data

2

Net data

Output data

3

Tare data

 

 

4

Gross data / Net data / Tare data

 

0

Stream mode

 

1

Manual mode

f37

2

Auto print mode(+)

Output mode

3

Auto print mode(+/-)

 

4

When accumulation, automatically output

 

** 5

Not output

f38

** 0

No delay

Delay for continual data

1

2.0 seconds (f36 4, except f37 0)

f39

0

600 bps

1

1200 bps

Baud rate

** 2

2400 bps

 

*: Initial settings.

bps: bit per second.

6.2. F-Functions

Page 28

AD-4405 Weighing Indicator

Image 30
Contents Weighing Indicator This manual and Marks Contents Setting the Parameters of Setpoint Comparison Compliance Compliance with FCC RulesCompliance with European Directives Introduction Installation and Precautions Installation and PrecautionsLoad Cell Connections Adjustment of the Load Cell Output Verifying Load Cell Output and Input SensitivityInstalling an Option Board Description of Panels and symbols Front Panel DescriptionOther Displays and Symbols Rear Panel DescriptionSupplemental accessories for printer Accessories and optionsStandard accessories OptionsItems of Calibration Mode CalibrationCalibration Procedure Configuring a Weighing InstrumentSpecifying the Resolution, Decimal Point Position and Format Specifying the Range and UnitSpecifying the Weighing Range of the First Range Specifying the Second Range ResolutionTo Get Stabilized Data Specifying the Second Range CapacityZero Calibration Span CalibrationExiting the Calibration Mode Weighing Range Function Setting the Division and Range Digital Linearization FunctionGravity Compensation Function Gravity Acceleration Table Calibration Error Code List Changing the Function Settings FunctionsFunctions OFFZERO+TARE = CAL EXT1 EXT2EXT3 Comparator Data Output Current Loop Output Serial Interface YY/MM/DD MM/DD/YY DD/MM/YYPrint Format CF-Functions Weighing Tare Digital Input Preset TareTare Clearing TarePreparation and Specifications AccumulationDisplay and Operation Parameter Using Code Memory Code MemoryWeight Check Mode ComparisonCondition formula for Comparison HI, OKLO, OK Setting the Upper/Lower Limit Values Setting Order and Display for Weight Check ModeMode F22 = 7 Check weighing Setpoint ComparisonDescription of Input parameters and Outputs Output and ConditionStart F22 = 9 Check weighing 3Loss in weightSimple Batch Weighing CompletionSetting the Parameters of Setpoint Comparison Toward the Zero bandReturns to Zero band Display and the Data Output of Hold and Average Setting the Hold FunctionsHold Function Relations to the Other FunctionsTARE, ZERO, SETPOINT, Total Key input and command in the hold stateConditions of the Average and Release MT, MZ, HCUsing the Counting Function Unit Weight RegistrationCounting Function Key to register the unit weight and return to the piece Calendar / Clock 13.1 Time and Date FunctionsYY/MM/DD Setting Time and Date Corrected date is as follows 05 05 Internal Printer OP-06 Installing the Printer Paper Special roll paper Replacing the Ink Ribbon15.1 Data Output / Print Mode Common Printer and Data Output ItemsData Number Interval Data Output / PrintSetting the Interval Time Interval Data Output / Print outputCircuit and Pin Connection 16.1 SpecificationsRS-232C Interface Bit FormatData Format FiguresCommand Format Explanation of CommandsCommands to Request Data Commands to Control the Indicator Changing the Weight Unit Changing the Code MemorySet the Unit Weight for Counting Mode Commands to Set ParametersSet the Preset Tare Set the Limit/Setpoint ValueStart Averaging to Hold Commands for the Hold FunctionCommands to Set the Data Output/ Print Format UFC Release the Hold DataUFC Commands UFC Command Parameters’$AN$TL$LF$LF $DLSF1,$ID$DN$CR$LF$GR$UT$CR$LF PF2,$DT$TM$LF$AN$SP$TL$LFCOM RS-422/RS-485, Relay OutputOP-03TRM CircuitSwitching Between RS-422/RS-485 Relay Output & Control Input OP-05 DC50VCircuits Specifications Settings19 -20mA Analog Output OP-07 Current Loop Output OP-08 CL1CL2 Current Loop Output Data FormatDigital Section SpecificationsAnalog Input and A/D Conversion InterfaceDimensions GeneralMemo Memo Memo