A&D AD-4405 manual Zero+Tare = Cal

Page 26

Display and Other General Functions

 

Item

 

Parameter

 

Description

 

 

 

f04

 

 

* 0

5 times/s

The selection in the unstable

Display update rate

 

 

1

10 times/s

condition.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 x

Key click

Left: Item, select using the

ZERO

 

 

 

 

(Sound or no)

 

key

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2 x

LoLo / Zero band

Right: Parameter, select using the

f05

[Type2]

 

3 x

LO

 

 

0 - 5 keys

 

 

 

Buzzer

 

4 x

OK

 

0: no sound,

1: continuous

 

 

 

5 x

HI

 

2: 4 times/s

3: 2 times/s

 

 

 

6 x

HiHi /

 

4: 1 time/s

5: 1 time/2s

 

 

 

Batch finish / Full

Initial value is 11, others x0.

 

 

 

 

 

f06

 

 

00 to

Command address

Initial setting is 00.

Device ID(Address)

 

99

or Device ID

 

 

 

 

 

 

 

 

f07

 

 

* 0

Disable

 

 

 

 

 

 

 

Counting function

 

 

1

Enable

 

 

 

 

 

 

 

*:

Initial settings.

 

 

s: second.

 

 

 

 

 

 

 

Key Switch

 

 

 

 

 

 

 

 

 

 

 

Item

 

Parameter

 

Description

 

 

 

 

 

 

10

11

CODE key

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20

21

SAMPLE key

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

30

31

SETPOINT key

Left: Key

 

 

 

 

 

 

40

41

PT key

 

 

 

 

 

 

Right: 0

Enable

 

 

 

 

 

 

 

 

 

50

51

TOTAL key

1

Disable

 

 

 

60

61

M+ key

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ZERO

key to select switch

f12

 

 

70

71

START key

[Type2]

 

 

0, 1 key to select

 

 

 

 

 

 

80

81

STOP key

Disabling key switch

 

 

Enable/Disable

 

 

 

 

 

 

90

91

FEED key

 

 

 

 

 

 

 

 

 

 

 

 

 

a0

a1

MODE key

These options could be ignored

 

 

 

b0

b1

ZERO key

when f13 to f15 is set to 17 and

 

 

 

 

 

 

shorting the terminal to the

 

 

 

C0

C1

TARE key

 

 

 

common.

 

 

 

 

 

 

 

d0

d1

NET/GROSS key

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

e0

e1

PRINT key

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

f0

f1

ZERO+TARE = CAL

 

 

 

 

 

 

 

*:

Initial settings.

 

 

 

 

 

 

 

 

 

 

6.2. F-Functions

Page 24

AD-4405 Weighing Indicator

Image 26
Contents Weighing Indicator This manual and Marks Contents Setting the Parameters of Setpoint Comparison Compliance with European Directives ComplianceCompliance with FCC Rules Introduction Load Cell Connections Installation and PrecautionsInstallation and Precautions Adjustment of the Load Cell Output Verifying Load Cell Output and Input SensitivityInstalling an Option Board Description of Panels and symbols Front Panel DescriptionOther Displays and Symbols Rear Panel DescriptionSupplemental accessories for printer Accessories and optionsStandard accessories OptionsItems of Calibration Mode CalibrationCalibration Procedure Configuring a Weighing InstrumentSpecifying the Resolution, Decimal Point Position and Format Specifying the Range and UnitSpecifying the Weighing Range of the First Range Specifying the Second Range ResolutionTo Get Stabilized Data Specifying the Second Range CapacityZero Calibration Span CalibrationExiting the Calibration Mode Weighing Range Function Setting the Division and Range Digital Linearization FunctionGravity Compensation Function Gravity Acceleration Table Calibration Error Code List Changing the Function Settings FunctionsFunctions OFFZERO+TARE = CAL EXT3 EXT1EXT2 Comparator Data Output Current Loop Output Serial Interface YY/MM/DD MM/DD/YY DD/MM/YYPrint Format CF-Functions Weighing Tare Digital Input Preset TareTare Clearing TarePreparation and Specifications AccumulationDisplay and Operation Parameter Using Code Memory Code MemoryWeight Check Mode ComparisonLO, OK Condition formula for ComparisonHI, OK Mode Setting the Upper/Lower Limit ValuesSetting Order and Display for Weight Check Mode F22 = 7 Check weighing Setpoint ComparisonDescription of Input parameters and Outputs Output and ConditionStart F22 = 9 Check weighing 3Loss in weightSimple Batch Weighing CompletionReturns to Zero band Setting the Parameters of Setpoint ComparisonToward the Zero band Display and the Data Output of Hold and Average Setting the Hold FunctionsHold Function Relations to the Other FunctionsTARE, ZERO, SETPOINT, Total Key input and command in the hold stateConditions of the Average and Release MT, MZ, HCCounting Function Using the Counting FunctionUnit Weight Registration Key to register the unit weight and return to the piece YY/MM/DD Calendar / Clock13.1 Time and Date Functions Setting Time and Date Corrected date is as follows 05 05 Internal Printer OP-06 Installing the Printer Paper Special roll paper Replacing the Ink Ribbon15.1 Data Output / Print Mode Common Printer and Data Output ItemsData Number Interval Data Output / PrintSetting the Interval Time Interval Data Output / Print outputCircuit and Pin Connection 16.1 SpecificationsRS-232C Interface Bit FormatData Format FiguresCommand Format Explanation of CommandsCommands to Request Data Commands to Control the Indicator Changing the Weight Unit Changing the Code MemorySet the Unit Weight for Counting Mode Commands to Set ParametersSet the Preset Tare Set the Limit/Setpoint ValueStart Averaging to Hold Commands for the Hold FunctionCommands to Set the Data Output/ Print Format UFC Release the Hold DataUFC Commands UFC Command Parameters’$AN$TL$LF$LF $DLSF1,$ID$DN$CR$LF$GR$UT$CR$LF PF2,$DT$TM$LF$AN$SP$TL$LFCOM RS-422/RS-485, Relay OutputOP-03TRM CircuitSwitching Between RS-422/RS-485 Circuits Relay Output & Control Input OP-05DC50V 19 -20mA Analog Output OP-07 SpecificationsSettings CL2 Current Loop Output OP-08CL1 Current Loop Output Data FormatDigital Section SpecificationsAnalog Input and A/D Conversion InterfaceDimensions GeneralMemo Memo Memo