A&D AD-4405 Setting the Upper/Lower Limit Values, Setting Order and Display for Weight Check Mode

Page 42

10.1.2.Setting the Upper/Lower Limit Values

Step 1 By pressing the SETPOINT key, the selected code memory number is displayed and the first comparison class term (ex. Hi, TG etc.) is blinking.

Step 2 Select the comparison class using the following keys:

 

 

 

SETPOINT

key ........The key to select a comparison class.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ESC

key ..................The key to return to the previous stage (weight display or

 

 

 

 

 

 

 

 

code memory number select).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ENTER

key..............The key to proceed to step 3.

 

 

 

Step 3

Set the setpoint values using the following keys:

 

 

 

 

 

 

 

 

0 - 9 key..................The key to enter a value.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ESC

key ..................The key to proceed to the next comparison class (step 2)

 

 

 

 

 

 

 

 

without changing the set value.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ENTER

key..............The key to store the value and proceed to the next

 

 

 

 

 

 

 

 

 

comparison class (step 2).

 

 

 

 

 

Setting Order and Display for Weight Check Mode

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

f22

MODE

 

Display

 

1

2

 

3

 

4

 

5

 

1

Upper

 

Setpoint

 

Upper

Lower

 

 

 

 

 

 

 

 

Lower 1

 

 

Class

 

Hi

Lo

 

 

 

 

 

 

 

 

 

 

 

 

Comparator

 

HI

LO

 

 

 

 

 

 

 

2

Upper

 

Setpoint

 

Target

Upper

 

Lower

 

 

 

 

 

 

Lower 2

 

 

Class

 

TG

Hi

 

Lo

 

 

 

 

 

 

 

 

 

 

Comparator

 

OK

HI

 

LO

 

 

 

 

 

3

Upper

 

Setpoint

 

Target

Upper

 

Lower

 

 

 

 

 

 

Lower 3

 

 

Class

 

TG

Hi

 

Lo

 

 

 

 

 

 

 

 

 

 

Comparator

 

OK

HI

 

LO

 

 

 

 

 

 

 

 

 

 

 

Unit

 

 

%

 

%

 

 

 

 

 

4

5-stage

 

Setpoint

 

HiHi

Hi

 

Lo

 

LoLo

 

 

 

 

1

 

 

Class

 

HH

Hi

 

Lo

 

LL

 

 

 

 

 

 

 

 

Comparator

 

HI

HI

 

LO

 

LO

 

 

 

 

 

 

 

 

Triangle

 

2

 

 

 

 

3

 

 

 

5

5-stage

 

Setpoint

 

Target

HiHi

 

Hi

 

Lo

 

LoLo

 

 

2

 

 

Class

 

TG

HH

 

Hi

 

Lo

 

LL

 

 

 

 

 

 

Comparator

 

OK

HI

 

HI

 

LO

 

LO

 

 

 

 

 

 

Triangle

 

 

2

 

 

 

 

 

3

 

6

5-stage

 

Setpoint

 

Target

HiHi

 

Hi

 

Lo

 

LoLo

 

 

3

 

 

Class

 

TG

HH

 

Hi

 

Lo

 

LL

 

 

 

 

 

 

Comparator

 

OK

HI

 

HI

 

LO

 

LO

 

 

 

 

 

 

 

Unit

 

 

%

 

%

 

%

 

%

 

 

 

 

 

 

Triangle

 

 

2

 

 

 

 

 

3

10.1. Weight Check Mode

Page 40

AD-4405 Weighing Indicator

Image 42
Contents Weighing Indicator This manual and Marks Contents Setting the Parameters of Setpoint Comparison Compliance Compliance with FCC RulesCompliance with European Directives Introduction Installation and Precautions Installation and PrecautionsLoad Cell Connections Adjustment of the Load Cell Output Verifying Load Cell Output and Input SensitivityInstalling an Option Board Description of Panels and symbols Front Panel DescriptionOther Displays and Symbols Rear Panel DescriptionSupplemental accessories for printer Accessories and optionsStandard accessories OptionsItems of Calibration Mode CalibrationCalibration Procedure Configuring a Weighing InstrumentSpecifying the Resolution, Decimal Point Position and Format Specifying the Range and UnitSpecifying the Weighing Range of the First Range Specifying the Second Range ResolutionTo Get Stabilized Data Specifying the Second Range CapacityZero Calibration Span CalibrationExiting the Calibration Mode Weighing Range Function Setting the Division and Range Digital Linearization FunctionGravity Compensation Function Gravity Acceleration Table Calibration Error Code List Changing the Function Settings FunctionsFunctions OFFZERO+TARE = CAL EXT1 EXT2EXT3 Comparator Data Output Current Loop Output Serial Interface YY/MM/DD MM/DD/YY DD/MM/YYPrint Format CF-Functions Weighing Tare Digital Input Preset TareTare Clearing TarePreparation and Specifications AccumulationDisplay and Operation Parameter Using Code Memory Code MemoryWeight Check Mode ComparisonCondition formula for Comparison HI, OKLO, OK Setting the Upper/Lower Limit Values Setting Order and Display for Weight Check ModeMode F22 = 7 Check weighing Setpoint ComparisonDescription of Input parameters and Outputs Output and ConditionStart F22 = 9 Check weighing 3Loss in weightSimple Batch Weighing CompletionSetting the Parameters of Setpoint Comparison Toward the Zero bandReturns to Zero band Display and the Data Output of Hold and Average Setting the Hold FunctionsHold Function Relations to the Other FunctionsTARE, ZERO, SETPOINT, Total Key input and command in the hold stateConditions of the Average and Release MT, MZ, HCUsing the Counting Function Unit Weight RegistrationCounting Function Key to register the unit weight and return to the piece Calendar / Clock 13.1 Time and Date FunctionsYY/MM/DD Setting Time and Date Corrected date is as follows 05 05 Internal Printer OP-06 Installing the Printer Paper Special roll paper Replacing the Ink Ribbon15.1 Data Output / Print Mode Common Printer and Data Output ItemsData Number Interval Data Output / PrintSetting the Interval Time Interval Data Output / Print outputCircuit and Pin Connection 16.1 SpecificationsRS-232C Interface Bit FormatData Format FiguresCommand Format Explanation of CommandsCommands to Request Data Commands to Control the Indicator Changing the Weight Unit Changing the Code MemorySet the Unit Weight for Counting Mode Commands to Set ParametersSet the Preset Tare Set the Limit/Setpoint ValueStart Averaging to Hold Commands for the Hold FunctionCommands to Set the Data Output/ Print Format UFC Release the Hold DataUFC Commands UFC Command Parameters’$AN$TL$LF$LF $DLSF1,$ID$DN$CR$LF$GR$UT$CR$LF PF2,$DT$TM$LF$AN$SP$TL$LFCOM RS-422/RS-485, Relay OutputOP-03TRM CircuitSwitching Between RS-422/RS-485 Relay Output & Control Input OP-05 DC50VCircuits Specifications Settings19 -20mA Analog Output OP-07 Current Loop Output OP-08 CL1CL2 Current Loop Output Data FormatDigital Section SpecificationsAnalog Input and A/D Conversion InterfaceDimensions GeneralMemo Memo Memo