Graco 332305B Alarm Output and Remote Illumination Response, Alarm Relay Response

Page 12

Installation

Alarm Output and Remote Illumination Response

The following tables include graphical representations of the connector as it appears on the unit, a pin-out associated with the connector and a typical installation wiring diagram. An internal representative wiring diagram is included where it is deemed useful.

Wire colors provided on these pages only refer to the power cable provided by Graco with this product.

 

 

Standard Remote

Tri-Color Remote

 

 

Illumination

Illumination

 

Alarm Output

(via 5 wire CPC power

(via illuminated manual run

 

cable)

input)

 

 

 

 

Unit in OFF Mode

Deactivated (off)

Off

Off

Unit in ON Mode

Deactivated (off)

On

Green

Warning Condition

Activated (on)

Toggles On and Off once

Yellow

per second

 

 

 

Fault Condition

Toggles On and Off

Toggles On and Off once

Red

once per second

per second

 

 

Fault Condition

Toggles On and Off

Toggles On and Off once

 

(Advanced Programming

Red

Setting A7 OFF)

once per second

per second

 

 

 

 

Fault Condition

 

Toggles On and Off once

 

(Advanced Programming

Activated (on)

Red

per second

Setting A7 ON)

 

 

 

 

 

Alarm Relay Response

Output Tied to Common

No Faults or

N.O.

 

 

 

 

 

 

 

Warnings

N.C.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

N.O.

Warning

 

 

 

 

 

 

 

 

N.C.

 

 

 

 

 

 

 

 

Fault

N.O.

 

 

 

 

 

 

 

(Advanced

N.C.

 

 

 

 

 

Programming A7

 

 

 

 

 

 

OFF)

 

 

 

 

 

 

 

 

 

 

1 second

 

 

 

 

 

 

 

 

 

 

 

 

Fault

N.O.

(Advanced

 

 

 

 

 

 

 

Programming

N.C.

Setting A7 ON)

12

332305B

Image 12
Contents Important Safety Instructions G3 Max Automatic Lubrication PumpContents Part / Model Numbers Liter ModelsPart Model Numbers G3-G-ACMX-8L0L00-1DMVA2R3 Understanding the Model Number Electric Shock Hazard Skin Injection Hazard Installation GroundingComponent Identification KeyTypical Installation Divider Installations Injector InstallationsChoosing an Installation Location Automatic System Activation HazardSystem Configuration and Wiring Recommendations for Using Pump in Harsh EnvironmentsFuses Input Voltage Fuse Value Graco Kit NoAlarm Output and Remote Illumination Response Alarm Relay ResponseWiring and Installation Diagrams Kits 571030571032 Power DIN AC 15 foot Part No U790 Connector on HousingConnector on Cable Example Wiring DiagramPower DIN DC 15 foot Part No U790 Connector on HousingConnector on Cable Example Wiring DiagramPower CPC DC -15 foot Part No Power CPC DC 5 Wire Manual OrangeDry Contacts Sink NPN 2 or 3 wire Source PNP 2 or 3 wire Inputs M12Vent Valve Outputs Alarm Outputs Part No Cable Pin Out M12 Wire Colors Part No Field Wireable Pin Out M12 Wire ColorsInstallation Setup Connecting to Auxiliary FittingsPressure Relief Pressure Relief ValvesSetting Pump Outlet Volume Output Volume / MinuteLoading Grease No. Spacers Cubic inches Cubic cmModels without a follower plate Changing GreasesFilling Oil Unit PrimingQuick Setup Guide Max Model Setup Control Panel Overview FIGPowering Units With Controllers Entering Setup ModeEntering a PIN Code to Access Setup Mode Programming the Max ModelSetting the Real Time Clock Enter the YearCycle C1, C2, C3 Setup Programming on DurationPressure Control P1, P2, P3 Setup Backup TimeInput Not Used Programming Backup Time On TimeProgramming on Time Pump OFF / Rest Setup Backup Time SetupMachine Count OFF Time Programming OFF TimePrelube Delay Setting PrelubePrelube Storing Pump Program Settings to the Flash Drive Uploading Pump Program Settings to the PumpDMS Models Only Downloading DataViewing the Unit DMS ID Number Operation / Data Log System Event LogSample System Event Log Error Log Sample Error LogCommon Error Log entries are listed below Functional Summary Sample Functional SummaryCommon Functional Summary Data entries are listed below Technical Summary Sample Technical SummaryAdvanced Programming PINEntering Advanced Setup Selecting Advanced Setup OptionsA1 Setting Up PIN Code Entering a PIN Code for the First TimeA2 Low Level Alarm Time A3 Vent Valve TimeAlarm Retry To set the Alarm RetryTo set Vent Valve Time Active Alarm Constant Alarm Output on Fault On OFF MM SS HH MMRun Mode Time ControlLubrication Mode Pump on Controls Cycle ControlPressure Control Backup Time Rest Mode Pump OFF ControlsMachine Count OFF TimePrelube / Prelube Delay Additional ControlsVenting Manual Run Cycle Alarms Fault / Warning ScenariosLow Level Fault Cycle PressureCycle Pressure Fault Machine Count FaultSystem Motor CurRent Warn IngUSB Error TemperaTure Warning Troubleshooting Problem Cause SolutionProblem Cause Solution Maintenance Frequency Component Required MaintenanceParts 2 Liter Models Parts 4 Liter and Larger Models Parts Part Description QtyPart Description Qty Part Description Qty 96G124, 96G175, 96G176, 96G186 96G188 Installation and Repair Kits Is not intended as a way to Relieve pressure during normalTechnical Data Dimensions Model Height Width Depth InchesMounting Pattern Option332305B Graco Standard Warranty Graco Information