Graco 332305B important safety instructions Cycle Pressure Fault, Machine Count Fault

Page 59

Alarms

Cycle /

Pressure

Fault

HH MM SS ##

ON OFF

MM : SS HH : MM

CP 1

 

 

CP 2

C

1 2 3

CP 3

P

 

!

In pressure mode indi- cates that unit is over pres- surized or a lubrication cycle was not completed in the user-defined amount of time.

In cycle mode indicates that a cycle was not com- pleted in the user-defined amount of time.

LED corresponding to the affected sensor input blinks.

Could be more than one sensor alarm at the same time.

Examine system to deter- mine if you have a plugged or broken line or other component failure, i.e., divider valve, injector.

Press and hold the RESET but- ton to clear fault.

Machine Count Fault

HH MM SS ##

ON OFF

MM : SS HH : MM

CP 1

 

 

CP 2

C

1 2 3

CP 3

P

 

!

Unit has not received the correct number of machine counts in the user defined Backup Time.

Examine system to deter- mine if the machine sen- sor is operating properly.

Press and hold the RESET but- ton to clear fault.

332305B

59

Image 59
Contents G3 Max Automatic Lubrication Pump Important Safety InstructionsContents Part Model Numbers Part / Model NumbersLiter Models G3-G-ACMX-8L0L00-1DMVA2R3 Understanding the Model Number Electric Shock Hazard Skin Injection Hazard Key InstallationGrounding Component IdentificationDivider Installations Injector Installations Typical InstallationAutomatic System Activation Hazard Choosing an Installation LocationInput Voltage Fuse Value Graco Kit No System Configuration and WiringRecommendations for Using Pump in Harsh Environments FusesAlarm Relay Response Alarm Output and Remote Illumination Response571032 Wiring and Installation DiagramsKits 571030 Example Wiring Diagram Power DIN AC 15 foot Part No U790Connector on Housing Connector on CableExample Wiring Diagram Power DIN DC 15 foot Part No U790Connector on Housing Connector on CablePower CPC DC -15 foot Part No Manual Orange Power CPC DC 5 WireInputs M12 Dry Contacts Sink NPN 2 or 3 wire Source PNP 2 or 3 wireVent Valve Outputs Alarm Outputs Part No Field Wireable Pin Out M12 Wire Colors Part No Cable Pin Out M12 Wire ColorsInstallation Pressure Relief Valves SetupConnecting to Auxiliary Fittings Pressure ReliefNo. Spacers Cubic inches Cubic cm Setting Pump Outlet VolumeOutput Volume / Minute Loading GreaseChanging Greases Models without a follower platePriming Filling Oil UnitQuick Setup Guide Control Panel Overview FIG Max Model SetupProgramming the Max Model Powering Units With ControllersEntering Setup Mode Entering a PIN Code to Access Setup ModeEnter the Year Setting the Real Time ClockProgramming on Duration Cycle C1, C2, C3 SetupInput Not Used Pressure Control P1, P2, P3 SetupBackup Time Programming on Time Programming Backup TimeOn Time Machine Count Pump OFF / Rest SetupBackup Time Setup Programming OFF Time OFF TimePrelube Prelube DelaySetting Prelube Downloading Data Storing Pump Program Settings to the Flash DriveUploading Pump Program Settings to the Pump DMS Models OnlyViewing the Unit DMS ID Number Sample System Event Log Operation / Data LogSystem Event Log Sample Error Log Error LogCommon Error Log entries are listed below Sample Functional Summary Functional SummaryCommon Functional Summary Data entries are listed below Sample Technical Summary Technical SummaryPIN Advanced ProgrammingEntering a PIN Code for the First Time Entering Advanced SetupSelecting Advanced Setup Options A1 Setting Up PIN CodeA3 Vent Valve Time A2 Low Level Alarm TimeTo set Vent Valve Time Alarm RetryTo set the Alarm Retry Active Alarm On OFF MM SS HH MM Constant Alarm Output on FaultTime Control Run ModePressure Control Lubrication Mode Pump on ControlsCycle Control Rest Mode Pump OFF Controls Backup TimeOFF Time Machine CountVenting Prelube / Prelube DelayAdditional Controls Manual Run Cycle Fault / Warning Scenarios AlarmsCycle Pressure Low Level FaultMachine Count Fault Cycle Pressure FaultIng SystemMotor Cur Rent WarnTure Warning USB ErrorTempera Problem Cause Solution TroubleshootingProblem Cause Solution Frequency Component Required Maintenance MaintenanceParts 2 Liter Models Parts 4 Liter and Larger Models Part Description Qty PartsPart Description Qty Part Description Qty 96G124, 96G175, 96G176, 96G186 96G188 Is not intended as a way to Relieve pressure during normal Installation and Repair KitsTechnical Data Model Height Width Depth Inches DimensionsOption Mounting Pattern332305B Graco Information Graco Standard Warranty