Graco 332305B important safety instructions On Time, Programming Backup Time, Programming on Time

Page 33

To determine the Backup Time, Graco recommends the user verify the length of time it takes to complete a typi- cal cycle and double that value (to a maximum of 30 minutes).

Backup Time is setup after Cycle or Pressure Sensor Setup is complete.

NOTE:

The LED next to the clock in the ON field lights, indi- cating the Backup Time is being programmed.

BACKUP (ON) Time is set as minutes and seconds (MM:SS) only.

The small flashing LED under the MM indicates you are setting minutes.

The first field (left side of display) blinks indicating the device is ready for you to begin programming.

Programming Backup Time

NOTE: When programming a time of less than 10 min- utes you must program the leading zero in the first num- ber field and press the ENTER button to save the zero selection.

1.To set the ON Time use the UP or DOWN ARROW button to scroll through numerals 0 to 5 until the desired number appears in the first MM (min- utes) field.

2.Press the ENTER button to lock in the selection. The next MM number field to the right flashes indicating it is ready for programming.

3.Use the UP or DOWN ARROW button to scroll through numerals 0 to 9 until the desired number appears in the second MM number field.

4.Press the ENTER button to lock in the selection.

The next number field to the right

flashes and the LED lights under SS; indicating it is ready to program the seconds fields.

5.Repeat steps 1 - 4 to set the SS (seconds) fields.

Max Model Setup

6.After pressing the ENTER button to set the last SS field, all the programmed ON Time information is saved.

The G3 automatically switches to the OFF Time

SETUP MODE.

ON Time

The LED next to the clock in the ON field lights, indicating you are setting the ON Time parameters.

ON Time is set in Minutes and Seconds (MM: SS).

An LED flashes under

either MM when pro-

 

gramming minutes

 

OR SS when pro-

OR

gramming seconds.

 

In SETUP MODE, the

number displayed in the first field, on the left side of display blinks, indicating the device is ready to pro- gram the ON Time minutes.

The total amount of ON Time cannot

exceed 30 minutes. If a value greater than 30 minutes is entered, the RED alarm LED lights and the value must be updated.

If this time does not meet the application needs, contact Graco Customer Support.

Programming ON Time

NOTE: When programming a time of less than 10 min- utes you must program a leading zero in the first num- ber field and press the ENTER button to save the zero selection.

1.To set the ON Time use the UP or DOWN ARROW button to scroll through numerals 0 to 5 until the desired number appears in the first MM (min- utes) field.

332305B

33

Image 33
Contents G3 Max Automatic Lubrication Pump Important Safety InstructionsContents Part / Model Numbers Liter ModelsPart Model Numbers G3-G-ACMX-8L0L00-1DMVA2R3 Understanding the Model Number Electric Shock Hazard Skin Injection Hazard Grounding InstallationComponent Identification KeyDivider Installations Injector Installations Typical InstallationAutomatic System Activation Hazard Choosing an Installation LocationRecommendations for Using Pump in Harsh Environments System Configuration and WiringFuses Input Voltage Fuse Value Graco Kit NoAlarm Relay Response Alarm Output and Remote Illumination ResponseWiring and Installation Diagrams Kits 571030571032 Connector on Housing Power DIN AC 15 foot Part No U790Connector on Cable Example Wiring DiagramConnector on Housing Power DIN DC 15 foot Part No U790Connector on Cable Example Wiring DiagramPower CPC DC -15 foot Part No Manual Orange Power CPC DC 5 WireInputs M12 Dry Contacts Sink NPN 2 or 3 wire Source PNP 2 or 3 wireVent Valve Outputs Alarm Outputs Part No Field Wireable Pin Out M12 Wire Colors Part No Cable Pin Out M12 Wire ColorsInstallation Connecting to Auxiliary Fittings SetupPressure Relief Pressure Relief ValvesOutput Volume / Minute Setting Pump Outlet VolumeLoading Grease No. Spacers Cubic inches Cubic cmChanging Greases Models without a follower platePriming Filling Oil UnitQuick Setup Guide Control Panel Overview FIG Max Model SetupEntering Setup Mode Powering Units With ControllersEntering a PIN Code to Access Setup Mode Programming the Max ModelEnter the Year Setting the Real Time ClockProgramming on Duration Cycle C1, C2, C3 SetupPressure Control P1, P2, P3 Setup Backup TimeInput Not Used Programming Backup Time On TimeProgramming on Time Pump OFF / Rest Setup Backup Time SetupMachine Count Programming OFF Time OFF TimePrelube Delay Setting PrelubePrelube Uploading Pump Program Settings to the Pump Storing Pump Program Settings to the Flash DriveDMS Models Only Downloading DataViewing the Unit DMS ID Number Operation / Data Log System Event LogSample System Event Log Sample Error Log Error LogCommon Error Log entries are listed below Sample Functional Summary Functional SummaryCommon Functional Summary Data entries are listed below Sample Technical Summary Technical SummaryPIN Advanced ProgrammingSelecting Advanced Setup Options Entering Advanced SetupA1 Setting Up PIN Code Entering a PIN Code for the First TimeA3 Vent Valve Time A2 Low Level Alarm TimeAlarm Retry To set the Alarm RetryTo set Vent Valve Time Active Alarm On OFF MM SS HH MM Constant Alarm Output on FaultTime Control Run ModeLubrication Mode Pump on Controls Cycle ControlPressure Control Rest Mode Pump OFF Controls Backup TimeOFF Time Machine CountPrelube / Prelube Delay Additional ControlsVenting Manual Run Cycle Fault / Warning Scenarios AlarmsCycle Pressure Low Level FaultMachine Count Fault Cycle Pressure FaultMotor Cur SystemRent Warn IngUSB Error TemperaTure Warning Problem Cause Solution TroubleshootingProblem Cause Solution Frequency Component Required Maintenance MaintenanceParts 2 Liter Models Parts 4 Liter and Larger Models Part Description Qty PartsPart Description Qty Part Description Qty 96G124, 96G175, 96G176, 96G186 96G188 Is not intended as a way to Relieve pressure during normal Installation and Repair KitsTechnical Data Model Height Width Depth Inches DimensionsOption Mounting Pattern332305B Graco Information Graco Standard Warranty