To determine the Backup Time, Graco recommends the user verify the length of time it takes to complete a typi- cal cycle and double that value (to a maximum of 30 minutes).
Backup Time is setup after Cycle or Pressure Sensor Setup is complete.
NOTE:
•The LED next to the clock in the ON field lights, indi- cating the Backup Time is being programmed.
•BACKUP (ON) Time is set as minutes and seconds (MM:SS) only.
•The small flashing LED under the MM indicates you are setting minutes.
•The first field (left side of display) blinks indicating the device is ready for you to begin programming.
Programming Backup Time
NOTE: When programming a time of less than 10 min- utes you must program the leading zero in the first num- ber field and press the ENTER button to save the zero selection.
1.To set the ON Time use the UP or DOWN ARROW button to scroll through numerals 0 to 5 until the desired number appears in the first MM (min- utes) field.
2.Press the ENTER button to lock in the selection. The next MM number field to the right flashes indicating it is ready for programming.
3.Use the UP or DOWN ARROW button to scroll through numerals 0 to 9 until the desired number appears in the second MM number field.
4.Press the ENTER button to lock in the selection.
The next number field to the right
flashes and the LED lights under SS; indicating it is ready to program the seconds fields.
5.Repeat steps 1 - 4 to set the SS (seconds) fields.
Max Model Setup
6.After pressing the ENTER button to set the last SS field, all the programmed ON Time information is saved.
The G3 automatically switches to the OFF Time
SETUP MODE.
ON Time
•The LED next to the clock in the ON field lights, indicating you are setting the ON Time parameters.
•ON Time is set in Minutes and Seconds (MM: SS).
•An LED flashes under
either MM when pro- |
| |
gramming minutes |
| |
OR SS when pro- | OR | |
gramming seconds. | ||
|
•In SETUP MODE, the
number displayed in the first field, on the left side of display blinks, indicating the device is ready to pro- gram the ON Time minutes.
•The total amount of ON Time cannot
exceed 30 minutes. If a value greater than 30 minutes is entered, the RED alarm LED lights and the value must be updated.
If this time does not meet the application needs, contact Graco Customer Support.
Programming ON Time
NOTE: When programming a time of less than 10 min- utes you must program a leading zero in the first num- ber field and press the ENTER button to save the zero selection.
1.To set the ON Time use the UP or DOWN ARROW button to scroll through numerals 0 to 5 until the desired number appears in the first MM (min- utes) field.
332305B | 33 |