Graco 332305B Pump OFF / Rest Setup, Machine Count, Backup Time Setup

Page 34

Max Model Setup

2.Press the ENTER button to lock in the selection. The next MM number field to the right flashes indicating it is ready for programming.

3.Use the UP or DOWN ARROW button to scroll through numerals 0 to 9 until the desired number appears in the second MM number field.

4.Press the ENTER button to lock in the selection.

The next number field to the right

flashes and the LED lights under SS; indicating it is ready to program the seconds fields.

5.Repeat steps 1 - 4 to set the SS (seconds) fields.

6.After pressing the ENTER button to set the last SS field, all the programmed ON Time information is saved.

The G3 automatically switches to the OFF Time

SETUP MODE.

PUMP OFF / REST Setup

After setting the parameters for either Cycle (C1, C2 or C3) or Pressure (P1, P2, or P3) ON modes, the OFF or pump rest cycle must be set up. There are 3 ways to control this function:

Machine Count switch activation, or

Machine Count activations limited by a maxi- mum Time, or

A specific set amount of Time (similar to Time Mode).

If the machine count sensor input is available and not used in the OFF Mode, the definition of the entered time is OFF TIME.

Machine Count

1.After you set the last ON Time field and press the ENTER button, the G3

automatically switches to the Machine Count setup.

Notice the LED next to 123 on the G3 display lights

indicating you are now in the Machine Count setup mode.

2.Press the UP or DOWN ARROW button to move up or down through number 0-9.

3.When the correct number displays, press the ENTER button to set the num- ber.

NOTE: If the machine count input is available on the unit and not used, the value MUST be set to zero (0).

4. Repeat 2 - 3 to set the remaining fields.

NOTE: After the Machine Count value is entered, the G3 can be programmed to backup the machine count input with time.

Backup Time Setup

1. The OFF Time LED lights.

OFF displays.

2.Press the UP or DOWN ARROW button to change OFF to ON on the display.

3.Press the ENTER button to set the selection.

Backup Time

The LED next to the clock in the OFF field lights, indicating you are setting the Backup Time parameters.

OFF Time is set in Hours and Minutes (HH: MM).

34

332305B

Image 34
Contents Important Safety Instructions G3 Max Automatic Lubrication PumpContents Liter Models Part / Model NumbersPart Model Numbers G3-G-ACMX-8L0L00-1DMVA2R3 Understanding the Model Number Electric Shock Hazard Skin Injection Hazard Component Identification InstallationGrounding KeyTypical Installation Divider Installations Injector InstallationsChoosing an Installation Location Automatic System Activation HazardFuses System Configuration and WiringRecommendations for Using Pump in Harsh Environments Input Voltage Fuse Value Graco Kit NoAlarm Output and Remote Illumination Response Alarm Relay ResponseKits 571030 Wiring and Installation Diagrams571032 Connector on Cable Power DIN AC 15 foot Part No U790Connector on Housing Example Wiring DiagramConnector on Cable Power DIN DC 15 foot Part No U790Connector on Housing Example Wiring DiagramPower CPC DC -15 foot Part No Power CPC DC 5 Wire Manual OrangeDry Contacts Sink NPN 2 or 3 wire Source PNP 2 or 3 wire Inputs M12Vent Valve Outputs Alarm Outputs Part No Cable Pin Out M12 Wire Colors Part No Field Wireable Pin Out M12 Wire ColorsInstallation Pressure Relief SetupConnecting to Auxiliary Fittings Pressure Relief ValvesLoading Grease Setting Pump Outlet VolumeOutput Volume / Minute No. Spacers Cubic inches Cubic cmModels without a follower plate Changing GreasesFilling Oil Unit PrimingQuick Setup Guide Max Model Setup Control Panel Overview FIGEntering a PIN Code to Access Setup Mode Powering Units With ControllersEntering Setup Mode Programming the Max ModelSetting the Real Time Clock Enter the YearCycle C1, C2, C3 Setup Programming on DurationBackup Time Pressure Control P1, P2, P3 SetupInput Not Used On Time Programming Backup TimeProgramming on Time Backup Time Setup Pump OFF / Rest SetupMachine Count OFF Time Programming OFF TimeSetting Prelube Prelube DelayPrelube DMS Models Only Storing Pump Program Settings to the Flash DriveUploading Pump Program Settings to the Pump Downloading DataViewing the Unit DMS ID Number System Event Log Operation / Data LogSample System Event Log Error Log Sample Error LogCommon Error Log entries are listed below Functional Summary Sample Functional SummaryCommon Functional Summary Data entries are listed below Technical Summary Sample Technical SummaryAdvanced Programming PINA1 Setting Up PIN Code Entering Advanced SetupSelecting Advanced Setup Options Entering a PIN Code for the First TimeA2 Low Level Alarm Time A3 Vent Valve TimeTo set the Alarm Retry Alarm RetryTo set Vent Valve Time Active Alarm Constant Alarm Output on Fault On OFF MM SS HH MMRun Mode Time ControlCycle Control Lubrication Mode Pump on ControlsPressure Control Backup Time Rest Mode Pump OFF ControlsMachine Count OFF TimeAdditional Controls Prelube / Prelube DelayVenting Manual Run Cycle Alarms Fault / Warning ScenariosLow Level Fault Cycle PressureCycle Pressure Fault Machine Count FaultRent Warn SystemMotor Cur IngTempera USB ErrorTure Warning Troubleshooting Problem Cause SolutionProblem Cause Solution Maintenance Frequency Component Required MaintenanceParts 2 Liter Models Parts 4 Liter and Larger Models Parts Part Description QtyPart Description Qty Part Description Qty 96G124, 96G175, 96G176, 96G186 96G188 Installation and Repair Kits Is not intended as a way to Relieve pressure during normalTechnical Data Dimensions Model Height Width Depth InchesMounting Pattern Option332305B Graco Standard Warranty Graco Information