Alarms
Low Level Fault
HH MM SS ##
ON OFF
MM : SS HH : MM
CP 1 |
|
|
CP 2 | C | 1 2 3 |
CP 3 | P |
|
! |
Level of lubricant in reservoir is low and addi- tional lubricant needs to be added.
Unit stops pumping and displays amount of accu- mulated time since the alarm was triggered.
Add lubricant to reservoir.
After lubri- cant is added press and hold the
RESET button to clear fault.
If repriming pump is required, the low level alarm time should be decreased. See
Cycle /
Pressure
Warning
HH MM SS ##
ON OFF
MM : SS HH : MM
CP 1 |
|
|
CP 2 | C | 1 2 3 |
CP 3 | P |
|
! |
System fails to relieve pressure or a lubrication cycle was not completed in the
Unit will continue to oper- ate for the number of lubri- cation cycles set by the warning retry parameter (see Advanced Program- ming, page 45).
If the warning condition clears itself on the next automatic lubrication cycle, the warning is cleared and the unit continues normal operation.
Examine system to deter- mine if you have a plugged or broken line or other component failure, i.e., divider valve, injector.
Press the RESET but- ton to clear warning.
58 | 332305B |