Graco 332305B important safety instructions Programming on Duration, Cycle C1, C2, C3 Setup

Page 31

Max Model Setup

The first programmable number of the HH (hour) filed blinks, indicating the device is ready to program the first digit of the hour.

When programming a time of less then 12 hours, you must program a leading zero in the first number field and press the ENTER button to save the zero.

1.Use the UP and DOWN ARROW buttons to move up and down through the numbers 0-2 until the desired number appears in the first hour (HH) field.

2.Press the ENTER button to set the number.

3.Use the UP and DOWN ARROW buttons to move up and down through the numbers 0-9 until the desired number for the second HH number field appears.

4.Press the ENTER button to set the number.

5.The next number field to the right blinks and the LED under the MM lights indicating the G3 is ready to program the minutes fields.

6.Repeat steps 1-4 to set the minutes (MM) fields.

7.After pressing the ENTER button to set the time, the programmed Time information is saved.

Programming ON Duration

OFF, C1 (C2, C3) or

P1 (P2, P3) displays, identifying the func- tion you are program- ming.

Selection of OFF, C1 (C2, C3) or P1 (P2, P3) desig- nates the way pump run time is controlled:

C1, C2, C3 - Completing a specific number of cycles measured by an external prox/cycle switch

P1, P2, P3 - Reaching a specific pressure threshold measured by an external pressure switch - OR,

OFF - A specific duration of time elapses.

The LED next to C/P1 lights, indicat- ing which sensor of the pump control you are programming using either a specific number of cycles or by mon- itoring a pressure switch.

C / P2 and C / P3 controls functions to the second and third sensors (when sensors are used).

Only sensor inputs that are available on the unit can be programmed.

NOTE: Field cannot be left blank. If C / P2 and C / P3 are not used, OFF must be entered instead.

Cycle (C1, C2, C3) Setup

Cycle controls the number of lube cycles (as monitored by an external cycle monitor) completed before the pump rests.

NOTE:

You must program at least one cycle. Zero is not an available option.

1.Use UP or DOWN arrow but- ton to toggle display between OFF / C1 / P1 on the display.

2.When C1 is on display,

press the

ENTER

button to save selec-

tion and begin programming Cycle data.

The first number

displayed after the “C1” on the dis- play blinks, indi- cating the device is ready to pro-

gram the number of C1 cycles.

The LED under the

# sign lights when setting the number of cycles.

3.Program the number of cycles by pressing the UP or DOWN ARROW button to move up or down through number 0-9.

332305B

31

Image 31
Contents G3 Max Automatic Lubrication Pump Important Safety InstructionsContents Liter Models Part / Model NumbersPart Model Numbers G3-G-ACMX-8L0L00-1DMVA2R3 Understanding the Model Number Electric Shock Hazard Skin Injection Hazard Key InstallationGrounding Component IdentificationDivider Installations Injector Installations Typical InstallationAutomatic System Activation Hazard Choosing an Installation LocationInput Voltage Fuse Value Graco Kit No System Configuration and WiringRecommendations for Using Pump in Harsh Environments FusesAlarm Relay Response Alarm Output and Remote Illumination ResponseKits 571030 Wiring and Installation Diagrams571032 Example Wiring Diagram Power DIN AC 15 foot Part No U790Connector on Housing Connector on CableExample Wiring Diagram Power DIN DC 15 foot Part No U790Connector on Housing Connector on CablePower CPC DC -15 foot Part No Manual Orange Power CPC DC 5 WireInputs M12 Dry Contacts Sink NPN 2 or 3 wire Source PNP 2 or 3 wireVent Valve Outputs Alarm Outputs Part No Field Wireable Pin Out M12 Wire Colors Part No Cable Pin Out M12 Wire ColorsInstallation Pressure Relief Valves SetupConnecting to Auxiliary Fittings Pressure ReliefNo. Spacers Cubic inches Cubic cm Setting Pump Outlet VolumeOutput Volume / Minute Loading GreaseChanging Greases Models without a follower platePriming Filling Oil UnitQuick Setup Guide Control Panel Overview FIG Max Model SetupProgramming the Max Model Powering Units With ControllersEntering Setup Mode Entering a PIN Code to Access Setup ModeEnter the Year Setting the Real Time ClockProgramming on Duration Cycle C1, C2, C3 SetupBackup Time Pressure Control P1, P2, P3 SetupInput Not Used On Time Programming Backup TimeProgramming on Time Backup Time Setup Pump OFF / Rest SetupMachine Count Programming OFF Time OFF TimeSetting Prelube Prelube DelayPrelube Downloading Data Storing Pump Program Settings to the Flash DriveUploading Pump Program Settings to the Pump DMS Models OnlyViewing the Unit DMS ID Number System Event Log Operation / Data LogSample System Event Log Sample Error Log Error LogCommon Error Log entries are listed below Sample Functional Summary Functional SummaryCommon Functional Summary Data entries are listed below Sample Technical Summary Technical SummaryPIN Advanced ProgrammingEntering a PIN Code for the First Time Entering Advanced SetupSelecting Advanced Setup Options A1 Setting Up PIN CodeA3 Vent Valve Time A2 Low Level Alarm TimeTo set the Alarm Retry Alarm RetryTo set Vent Valve Time Active Alarm On OFF MM SS HH MM Constant Alarm Output on FaultTime Control Run ModeCycle Control Lubrication Mode Pump on ControlsPressure Control Rest Mode Pump OFF Controls Backup TimeOFF Time Machine CountAdditional Controls Prelube / Prelube DelayVenting Manual Run Cycle Fault / Warning Scenarios AlarmsCycle Pressure Low Level FaultMachine Count Fault Cycle Pressure FaultIng SystemMotor Cur Rent WarnTempera USB ErrorTure Warning Problem Cause Solution TroubleshootingProblem Cause Solution Frequency Component Required Maintenance MaintenanceParts 2 Liter Models Parts 4 Liter and Larger Models Part Description Qty PartsPart Description Qty Part Description Qty 96G124, 96G175, 96G176, 96G186 96G188 Is not intended as a way to Relieve pressure during normal Installation and Repair KitsTechnical Data Model Height Width Depth Inches DimensionsOption Mounting Pattern332305B Graco Information Graco Standard Warranty