Graco 332305B Common Functional Summary Data entries are listed below

Page 43

Operation / Data Log

Common Functional Summary Data entries are listed below.

Number of Cycles

The number of lubrication cycles

 

the unit has started.

 

 

Total Run Hours

Total amount of hours the pump

 

has been in the ON mode of the

 

ON/OFF cycle.

 

 

Total Powered On Hours

Total number of hours that the

 

unit has been powered on.

 

 

Local Manual Run

The number of times the manual

 

run button was pressed.

 

 

Remote Manual Run

The number of times the remote

 

manual run button was pressed.

 

 

Average Run Time

The average amount of time per

 

lubrication cycle that the pump

 

has been running (MM:SS).

 

 

Average Cycle 1 Time

The average amount of time the

 

unit has been operating before

Average Cycle 2 Time

the specified feedback for the

 

Average Cycle 3 Time

sensor input was received (prox-

 

 

imity switch counts in divider

 

valve systems and pressure

 

switch activation in injector sys-

 

tems).

 

 

Average Duty Cycle

The average percentage of time

 

the unit has been pumping while

 

it has been powered on.

 

 

Max Duty Cycle

The highest percentage of time

 

for one lubrication cycle that the

 

unit has been pumping while it

 

has been powered on.

 

 

Total Low Level Faults

Total number of low level faults.

 

 

Total Cycle Pressure

Total number of faults related to

Faults

sensor feedback in an injector or

 

divider valve system.

 

 

Total Other Faults

Faults other than low level or

 

sensor feedback.

 

 

Total Fault Hours

Number of hours the system has

 

been powered on in fault mode.

 

 

Total Low Level Warnings

Number of low level warning

 

conditions.

 

 

Total Cycle Pressure

Total number of warning condi-

Warnings

tions related to sensor feedback.

 

This is only applicable if fault

 

retries are used.

 

 

Total Other Warnings

All other warnings including tem-

 

perature and motor current.

 

 

332305B

43

Image 43
Contents G3 Max Automatic Lubrication Pump Important Safety InstructionsContents Liter Models Part / Model NumbersPart Model Numbers G3-G-ACMX-8L0L00-1DMVA2R3 Understanding the Model Number Electric Shock Hazard Skin Injection Hazard Key InstallationGrounding Component IdentificationDivider Installations Injector Installations Typical InstallationAutomatic System Activation Hazard Choosing an Installation LocationInput Voltage Fuse Value Graco Kit No System Configuration and WiringRecommendations for Using Pump in Harsh Environments FusesAlarm Relay Response Alarm Output and Remote Illumination ResponseKits 571030 Wiring and Installation Diagrams571032 Example Wiring Diagram Power DIN AC 15 foot Part No U790Connector on Housing Connector on CableExample Wiring Diagram Power DIN DC 15 foot Part No U790Connector on Housing Connector on CablePower CPC DC -15 foot Part No Manual Orange Power CPC DC 5 WireInputs M12 Dry Contacts Sink NPN 2 or 3 wire Source PNP 2 or 3 wireVent Valve Outputs Alarm Outputs Part No Field Wireable Pin Out M12 Wire Colors Part No Cable Pin Out M12 Wire ColorsInstallation Pressure Relief Valves SetupConnecting to Auxiliary Fittings Pressure ReliefNo. Spacers Cubic inches Cubic cm Setting Pump Outlet VolumeOutput Volume / Minute Loading GreaseChanging Greases Models without a follower platePriming Filling Oil UnitQuick Setup Guide Control Panel Overview FIG Max Model SetupProgramming the Max Model Powering Units With ControllersEntering Setup Mode Entering a PIN Code to Access Setup ModeEnter the Year Setting the Real Time ClockProgramming on Duration Cycle C1, C2, C3 SetupBackup Time Pressure Control P1, P2, P3 SetupInput Not Used On Time Programming Backup TimeProgramming on Time Backup Time Setup Pump OFF / Rest SetupMachine Count Programming OFF Time OFF TimeSetting Prelube Prelube DelayPrelube Downloading Data Storing Pump Program Settings to the Flash DriveUploading Pump Program Settings to the Pump DMS Models OnlyViewing the Unit DMS ID Number System Event Log Operation / Data LogSample System Event Log Sample Error Log Error LogCommon Error Log entries are listed below Sample Functional Summary Functional SummaryCommon Functional Summary Data entries are listed below Sample Technical Summary Technical SummaryPIN Advanced ProgrammingEntering a PIN Code for the First Time Entering Advanced SetupSelecting Advanced Setup Options A1 Setting Up PIN CodeA3 Vent Valve Time A2 Low Level Alarm TimeTo set the Alarm Retry Alarm RetryTo set Vent Valve Time Active Alarm On OFF MM SS HH MM Constant Alarm Output on FaultTime Control Run ModeCycle Control Lubrication Mode Pump on ControlsPressure Control Rest Mode Pump OFF Controls Backup TimeOFF Time Machine CountAdditional Controls Prelube / Prelube DelayVenting Manual Run Cycle Fault / Warning Scenarios AlarmsCycle Pressure Low Level FaultMachine Count Fault Cycle Pressure FaultIng SystemMotor Cur Rent WarnTempera USB ErrorTure Warning Problem Cause Solution TroubleshootingProblem Cause Solution Frequency Component Required Maintenance MaintenanceParts 2 Liter Models Parts 4 Liter and Larger Models Part Description Qty PartsPart Description Qty Part Description Qty 96G124, 96G175, 96G176, 96G186 96G188 Is not intended as a way to Relieve pressure during normal Installation and Repair KitsTechnical Data Model Height Width Depth Inches DimensionsOption Mounting Pattern332305B Graco Information Graco Standard Warranty