Entering a PIN Code for the First Time

A1 - Setting Up PIN Code

A PIN Code can be programmed into the G3 to protect the settings from inadvertently being changed by unau- thorized users.

1.Press the UP ARROW button for 10 seconds.

The LED next to the LOCK ICON on the display lights, indicating you have entered the PIN Mode.

2.The word OFF appears in the display. Press the UP or DOWN ARROW button to change this to ON.

3.Press the ENTER button to enter the PIN Code.

4.The cursor automatically is positioned to entered the first character of the PIN Code. Use the UP and DOWN ARROW buttons to move up

and down through the numbers 0-9 until the first number in the PIN code is displayed in the field.

5.Press the ENTER button to set the number. The cursor automatically moves to the next number field.

6.Repeat steps 4 and 5 for each PIN Code prompt field.

7.Press the ENTER button to save the PIN Code and exit Advanced Setup.

Entering Advanced Setup

Press the UP ARROW button for 10 sec- onds.

If the G3 was previously set up to require a

PIN Code, the LED next to the LOCK ICON lights, indi- cating a PIN Code is required.

1.The cursor is automatically positioned to enter the first character of the PIN Code. Use the UP and DOWN ARROW buttons to move up

and down through the numbers 0-9 until the first number in the PIN code is displayed in the field.

2.Press the ENTER button to set the num- ber. The cursor automatically moves to the next number field.

3.Repeat steps 1 and 2 for each PIN Code prompt field.

If the PIN Code you entered is correct, the first editable character on the display will flash.

Selecting Advanced Setup Options

1.Press the UP or DOWN ARROW button to move up or down through Advanced Options A1 - A7.

2.Press the ENTER button to set the selection.

46

332305B

Image 46
Contents Important Safety Instructions G3 Max Automatic Lubrication PumpContents Liter Models Part / Model NumbersPart Model Numbers G3-G-ACMX-8L0L00-1DMVA2R3 Understanding the Model Number Electric Shock Hazard Skin Injection Hazard Component Identification InstallationGrounding KeyTypical Installation Divider Installations Injector InstallationsChoosing an Installation Location Automatic System Activation HazardFuses System Configuration and WiringRecommendations for Using Pump in Harsh Environments Input Voltage Fuse Value Graco Kit NoAlarm Output and Remote Illumination Response Alarm Relay ResponseKits 571030 Wiring and Installation Diagrams571032 Connector on Cable Power DIN AC 15 foot Part No U790Connector on Housing Example Wiring DiagramConnector on Cable Power DIN DC 15 foot Part No U790Connector on Housing Example Wiring DiagramPower CPC DC -15 foot Part No Power CPC DC 5 Wire Manual OrangeDry Contacts Sink NPN 2 or 3 wire Source PNP 2 or 3 wire Inputs M12Vent Valve Outputs Alarm Outputs Part No Cable Pin Out M12 Wire Colors Part No Field Wireable Pin Out M12 Wire ColorsInstallation Pressure Relief SetupConnecting to Auxiliary Fittings Pressure Relief ValvesLoading Grease Setting Pump Outlet VolumeOutput Volume / Minute No. Spacers Cubic inches Cubic cmModels without a follower plate Changing GreasesFilling Oil Unit PrimingQuick Setup Guide Max Model Setup Control Panel Overview FIGEntering a PIN Code to Access Setup Mode Powering Units With ControllersEntering Setup Mode Programming the Max ModelSetting the Real Time Clock Enter the YearCycle C1, C2, C3 Setup Programming on DurationBackup Time Pressure Control P1, P2, P3 SetupInput Not Used On Time Programming Backup TimeProgramming on Time Backup Time Setup Pump OFF / Rest SetupMachine Count OFF Time Programming OFF TimeSetting Prelube Prelube DelayPrelube DMS Models Only Storing Pump Program Settings to the Flash DriveUploading Pump Program Settings to the Pump Downloading DataViewing the Unit DMS ID Number System Event Log Operation / Data LogSample System Event Log Error Log Sample Error LogCommon Error Log entries are listed below Functional Summary Sample Functional SummaryCommon Functional Summary Data entries are listed below Technical Summary Sample Technical SummaryAdvanced Programming PINA1 Setting Up PIN Code Entering Advanced SetupSelecting Advanced Setup Options Entering a PIN Code for the First TimeA2 Low Level Alarm Time A3 Vent Valve TimeTo set the Alarm Retry Alarm RetryTo set Vent Valve Time Active Alarm Constant Alarm Output on Fault On OFF MM SS HH MMRun Mode Time ControlCycle Control Lubrication Mode Pump on ControlsPressure Control Backup Time Rest Mode Pump OFF ControlsMachine Count OFF TimeAdditional Controls Prelube / Prelube DelayVenting Manual Run Cycle Alarms Fault / Warning ScenariosLow Level Fault Cycle PressureCycle Pressure Fault Machine Count FaultRent Warn SystemMotor Cur IngTempera USB ErrorTure Warning Troubleshooting Problem Cause SolutionProblem Cause Solution Maintenance Frequency Component Required MaintenanceParts 2 Liter Models Parts 4 Liter and Larger Models Parts Part Description QtyPart Description Qty Part Description Qty 96G124, 96G175, 96G176, 96G186 96G188 Installation and Repair Kits Is not intended as a way to Relieve pressure during normalTechnical Data Dimensions Model Height Width Depth InchesMounting Pattern Option332305B Graco Standard Warranty Graco Information