Filling Oil Unit

Only use oil appropriate for your application, auto- matic dispensing, and the equipment’s operating temperature. Consult with machine and lube manu- facturer for details.

The reservoir can be filled using a hand operated pump, pneumatic pump or electric transfer pump.

Do not overfill (FIG. 19).

Do not operate G3 without reservoir attached.

Only use oils with viscosity at least 40 cSt.

a

b

FIG. 20

2.Only run pump until air is no longer dispensed with the lubricant coming out of element fitting (FIG. 21).

FIG. 19

1.Remove fill cap (a).

2.Pour oil into reservoir to fill line (b).

3.Replace fill cap. Hand tighten cap, securely.

Priming

NOTE: It is not necessary to prime pump every time pump is filled with lubricant.

Pump only requires priming the first time it is used or if it is allowed to run dry.

1. Loosen pump element fitting (FIG. 20).

NOTE: When loosening pump element fitting, do NOT loosen pump element. Loosening pump element will change the output volume

FIG. 21

3.Tighten pump element fitting using two wrenches working in opposite directions (FIG. 20).

26

332305B

Image 26
Contents Important Safety Instructions G3 Max Automatic Lubrication PumpContents Part Model Numbers Part / Model NumbersLiter Models G3-G-ACMX-8L0L00-1DMVA2R3 Understanding the Model Number Electric Shock Hazard Skin Injection Hazard Component Identification InstallationGrounding KeyTypical Installation Divider Installations Injector InstallationsChoosing an Installation Location Automatic System Activation HazardFuses System Configuration and WiringRecommendations for Using Pump in Harsh Environments Input Voltage Fuse Value Graco Kit NoAlarm Output and Remote Illumination Response Alarm Relay Response571032 Wiring and Installation DiagramsKits 571030 Connector on Cable Power DIN AC 15 foot Part No U790Connector on Housing Example Wiring DiagramConnector on Cable Power DIN DC 15 foot Part No U790Connector on Housing Example Wiring DiagramPower CPC DC -15 foot Part No Power CPC DC 5 Wire Manual OrangeDry Contacts Sink NPN 2 or 3 wire Source PNP 2 or 3 wire Inputs M12Vent Valve Outputs Alarm Outputs Part No Cable Pin Out M12 Wire Colors Part No Field Wireable Pin Out M12 Wire ColorsInstallation Pressure Relief SetupConnecting to Auxiliary Fittings Pressure Relief ValvesLoading Grease Setting Pump Outlet VolumeOutput Volume / Minute No. Spacers Cubic inches Cubic cmModels without a follower plate Changing GreasesFilling Oil Unit PrimingQuick Setup Guide Max Model Setup Control Panel Overview FIGEntering a PIN Code to Access Setup Mode Powering Units With ControllersEntering Setup Mode Programming the Max ModelSetting the Real Time Clock Enter the YearCycle C1, C2, C3 Setup Programming on DurationInput Not Used Pressure Control P1, P2, P3 SetupBackup Time Programming on Time Programming Backup TimeOn Time Machine Count Pump OFF / Rest SetupBackup Time Setup OFF Time Programming OFF TimePrelube Prelube DelaySetting Prelube DMS Models Only Storing Pump Program Settings to the Flash DriveUploading Pump Program Settings to the Pump Downloading DataViewing the Unit DMS ID Number Sample System Event Log Operation / Data LogSystem Event Log Error Log Sample Error LogCommon Error Log entries are listed below Functional Summary Sample Functional SummaryCommon Functional Summary Data entries are listed below Technical Summary Sample Technical SummaryAdvanced Programming PINA1 Setting Up PIN Code Entering Advanced SetupSelecting Advanced Setup Options Entering a PIN Code for the First TimeA2 Low Level Alarm Time A3 Vent Valve TimeTo set Vent Valve Time Alarm RetryTo set the Alarm Retry Active Alarm Constant Alarm Output on Fault On OFF MM SS HH MMRun Mode Time ControlPressure Control Lubrication Mode Pump on ControlsCycle Control Backup Time Rest Mode Pump OFF ControlsMachine Count OFF TimeVenting Prelube / Prelube DelayAdditional Controls Manual Run Cycle Alarms Fault / Warning ScenariosLow Level Fault Cycle PressureCycle Pressure Fault Machine Count FaultRent Warn SystemMotor Cur IngTure Warning USB ErrorTempera Troubleshooting Problem Cause SolutionProblem Cause Solution Maintenance Frequency Component Required MaintenanceParts 2 Liter Models Parts 4 Liter and Larger Models Parts Part Description QtyPart Description Qty Part Description Qty 96G124, 96G175, 96G176, 96G186 96G188 Installation and Repair Kits Is not intended as a way to Relieve pressure during normalTechnical Data Dimensions Model Height Width Depth InchesMounting Pattern Option332305B Graco Standard Warranty Graco Information