Graco 332305B important safety instructions Tempera, Ture Warning, USB Error

Page 61

Alarms

Tempera-

 

 

 

 

The internal temperature of

Ensure the unit is used in

ture Warning

 

 

 

!

the unit is out of its recom-

the correct operating envi-

HH

MM

SS

##

mended operating range.

ronment for the specific

 

 

 

 

 

 

 

 

 

temperature: -13° F to

 

 

 

 

 

Use of the unit outside of

158° F (-25° C to 70°C).

ON

 

OFF

 

the recommended tem-

If necessary contact

 

 

perature range could cause

MM : SS

HH : MM

 

 

degraded system perfor-

Graco Customer Service.

 

 

 

 

 

mance and possible dam-

 

CP 1

 

 

 

 

age.

 

CP 2

C

 

1 2 3

 

 

 

CP 3

P

 

 

 

 

 

USB Error

 

 

 

An error occurred during a

Read the Troubleshoot-

 

 

 

 

DMS operation.

ing section of this manual

HH

MM

SS

##

!

(page 62) for error num-

 

 

 

 

 

 

 

bers and fault descrip-

 

 

 

 

 

tions.

ON OFF

MM : SS HH : MM

CP 1

 

 

CP 2

C

1 2 3

CP 3

P

 

332305B

61

Image 61
Contents G3 Max Automatic Lubrication Pump Important Safety InstructionsContents Liter Models Part / Model NumbersPart Model Numbers G3-G-ACMX-8L0L00-1DMVA2R3 Understanding the Model Number Electric Shock Hazard Skin Injection Hazard Grounding InstallationComponent Identification KeyDivider Installations Injector Installations Typical InstallationAutomatic System Activation Hazard Choosing an Installation LocationRecommendations for Using Pump in Harsh Environments System Configuration and WiringFuses Input Voltage Fuse Value Graco Kit NoAlarm Relay Response Alarm Output and Remote Illumination ResponseKits 571030 Wiring and Installation Diagrams571032 Connector on Housing Power DIN AC 15 foot Part No U790Connector on Cable Example Wiring DiagramConnector on Housing Power DIN DC 15 foot Part No U790Connector on Cable Example Wiring DiagramPower CPC DC -15 foot Part No Manual Orange Power CPC DC 5 WireInputs M12 Dry Contacts Sink NPN 2 or 3 wire Source PNP 2 or 3 wireVent Valve Outputs Alarm Outputs Part No Field Wireable Pin Out M12 Wire Colors Part No Cable Pin Out M12 Wire ColorsInstallation Connecting to Auxiliary Fittings SetupPressure Relief Pressure Relief ValvesOutput Volume / Minute Setting Pump Outlet VolumeLoading Grease No. Spacers Cubic inches Cubic cmChanging Greases Models without a follower platePriming Filling Oil UnitQuick Setup Guide Control Panel Overview FIG Max Model SetupEntering Setup Mode Powering Units With ControllersEntering a PIN Code to Access Setup Mode Programming the Max ModelEnter the Year Setting the Real Time ClockProgramming on Duration Cycle C1, C2, C3 SetupBackup Time Pressure Control P1, P2, P3 SetupInput Not Used On Time Programming Backup TimeProgramming on Time Backup Time Setup Pump OFF / Rest SetupMachine Count Programming OFF Time OFF TimeSetting Prelube Prelube DelayPrelube Uploading Pump Program Settings to the Pump Storing Pump Program Settings to the Flash DriveDMS Models Only Downloading DataViewing the Unit DMS ID Number System Event Log Operation / Data LogSample System Event Log Sample Error Log Error LogCommon Error Log entries are listed below Sample Functional Summary Functional SummaryCommon Functional Summary Data entries are listed below Sample Technical Summary Technical SummaryPIN Advanced ProgrammingSelecting Advanced Setup Options Entering Advanced SetupA1 Setting Up PIN Code Entering a PIN Code for the First TimeA3 Vent Valve Time A2 Low Level Alarm TimeTo set the Alarm Retry Alarm RetryTo set Vent Valve Time Active Alarm On OFF MM SS HH MM Constant Alarm Output on FaultTime Control Run ModeCycle Control Lubrication Mode Pump on ControlsPressure Control Rest Mode Pump OFF Controls Backup TimeOFF Time Machine CountAdditional Controls Prelube / Prelube DelayVenting Manual Run Cycle Fault / Warning Scenarios AlarmsCycle Pressure Low Level FaultMachine Count Fault Cycle Pressure FaultMotor Cur SystemRent Warn IngTempera USB ErrorTure Warning Problem Cause Solution TroubleshootingProblem Cause Solution Frequency Component Required Maintenance MaintenanceParts 2 Liter Models Parts 4 Liter and Larger Models Part Description Qty PartsPart Description Qty Part Description Qty 96G124, 96G175, 96G176, 96G186 96G188 Is not intended as a way to Relieve pressure during normal Installation and Repair KitsTechnical Data Model Height Width Depth Inches DimensionsOption Mounting Pattern332305B Graco Information Graco Standard Warranty