CONTROL CAbLE
CONTROL CAbLE CONNECTIONS
•All system control cables are the same.
•All control cables can be connected end to end to extend their length.
•All system equipment must be connected to a con- trol cable.
Typical bench Feeder Connection:
Control cable is connected from the Power Wave Source output Amphenol receptacle to the input Amphenol receptacle on the back of the Wire Drive.
Digital Control Cable, K1543-xx
Power Source | Wire Feeder | ||
Amphenol Plug | Amphenol Plug | ||
|
| ||
| E | D | E |
D | A | A | |
C | B | C | B |
Pin | Function |
ADigital I/O
B Digital I/O
C "67" voltage sense
D 40 VDC
E 40 VDC
Use a maximum of 250 feet (76.2m) of control cable between components.
Welding Gun/Wire Feeder Trigger Connector
Wire Feeder | ||
Amphenol |
| |
D | E A | Welding Gun |
C | B | Trigger Lead |
Wire Feeder
Pin | Function |
A | Gun Trigger |
B | - |
C | Common |
D | Dual Procedure |
E | Common |
|
|
CONTROL CAbLE SPECIFICATIONS
It is recommended that only genuine Lincoln control cables be used at all times. Lincoln cables are specifi- cally designed for the communication and power needs of the Power Wave Source / Power Feed sys- tem. The use of
Lincoln control cables are copper 5 conductor cable in a
AVAILAbLE CONTROL CAbLE
K1543 Control cable only. Available in lengths of 8'(2.4m), 16'(4.9m), 25'(7.6m), 50'(15.2m) and 100'(30.5m).