Lincoln Electric IM827-D Parameter Definition Show Test Modes, View Diagnostics, View Event Logs

Page 38

b-15

OPERATION

b-15

 

 

 

 

USER DEFINED PARAMETERS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Parameter

Definition

 

 

 

 

 

P.99

Show Test Modes

 

 

 

 

 

 

Most power sources contain weld modes used for calibration and test purposes. By default, the machine

 

 

 

 

 

does not include test weld modes in the list of weld modes that are available to the operator. To manually

 

 

 

 

 

select a test weld mode, set this option to "Yes". When the power source is turned off and back on again,

 

 

 

 

 

the test modes will no longer appear in the mode list. Test weld modes typically require the machine out-

 

 

 

 

 

put to be connected to a grid load and cannot be used for welding.

 

 

 

 

 

 

 

 

 

 

 

 

P.100

View Diagnostics

 

 

 

 

 

 

Diagnostics are only used for servicing or troubleshooting the Power Wave system. Select "Yes" to

 

 

 

 

 

access the diagnostic options in the menu. Additional parameters will now appear in the setup menu

 

 

 

 

 

(P.101, P.102, etc).

 

 

 

 

 

 

 

 

 

 

 

 

P.101

View Event Logs

 

 

 

 

 

 

Used for viewing all the system event logs. Press the right MSP Button to enter the option. Rotate Set

 

 

 

 

 

knob to select the desired system log to read. Press the right button again to enter the selected log.

 

 

 

 

 

Rotating the Set knob will scroll through the event log, displaying the log index number, event code and

 

 

 

 

 

some other data. Press the left button to back out to select another log. Press the left button again to exit

 

 

 

 

 

this option.

 

 

 

 

 

 

 

 

 

 

 

 

P.102

View Fatal Logs

 

 

 

 

 

 

Used for viewing all the system fatal logs. Press the right MSP Button to enter the option. Rotate Set knob

 

 

 

 

 

to select the desired log to read. Press the right button again to enter that log. Rotating the Set knob will

 

 

 

 

 

scroll through the log, displaying the log index number and fatal code. Press the left button to back out to

 

 

 

 

 

select another log. Press the left button again to exit this option.

 

 

 

 

 

 

 

 

 

 

 

 

P.103

View Software Version Information

 

 

 

 

 

 

Used for viewing the firmware versions for each board in the system. Press the right MSP

 

 

 

 

 

Button to enter the option. Rotate Set knob to select the desired board to read. Press the right

 

 

 

 

 

button again to read the firmware version. Press the left button to back out to select another

 

 

 

 

 

board. Rotate the SET knob to select another board, or press the left button to exit this option.

 

 

 

 

 

 

 

 

 

 

 

P.104

View Hardware Version Information

 

 

 

 

 

 

Used for viewing the hardware version for each board in the system. Press the right MSP

 

 

 

 

 

Button to enter the option. Rotate Set knob to select the desired board to read. Press the right

 

 

 

 

 

button again to read the hardware version. Press the left button to back out to select another

 

 

 

 

 

board. Press the left button again to exit this option.

 

 

 

 

 

 

 

 

 

 

 

 

P.105

View Welding Software Information

 

 

 

 

 

 

Used for viewing the Weld Set in the Power Source. Press the right MSP Button to read the

 

 

 

 

 

Weld Set version. Press the left button to back out and exit this option.

 

 

 

 

 

 

 

 

 

 

 

 

P.106

View Ethernet IP Address

 

 

 

 

 

 

Used for viewing the Ethernet Network IP address if there is an Ethernet board present in the

 

 

 

 

 

system. Press the right MSP Button to read the IP Address. Press the left button to back out

 

 

 

 

 

and exit this option. The IP address cannot be changed using this option.

 

 

 

 

 

 

 

 

 

 

 

 

P.107

View Power Source Protocol

 

 

 

 

 

 

Used for viewing the type of power source the feeder is connected to. Press the right MSP

 

 

 

 

 

Button to identify the power source as either LincNet or ArcLink. Press the left button to back

 

 

 

 

 

out and exit this option.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

POWER FEED 10M SINGLE WIRE FEEDER

Image 38
Contents Power Feed 10M Wire Feeder Safety Depends on YouSafety California Proposition 65 WarningsElectric Shock can kill Welding and Cutting Sparks can Cause fire or explosion IiiPrécautions DE Sûreté Please Examine Carton and Equipment For Damage Immediately On-Line Product RegistrationTAbLE of Contents TAbLE of Contents Temperature Rating InstallationSPEC.# Type Input Power Power Feed 10M Single Wire FeederLocation Wire Drive Mounting See Figure A.1Electric Shock can kill MountingWeld CAbLE SIzES Weld CAbLE SIzINGWeld CAbLE Connection Electrode LeadCOAxIAL Weld CAbLES Negative Electrode PolarityAVAILAbLE Control CAbLE Control CAbLE SpecificationsControl CAbLE Connections Changing Drive Rolls and Wire Guides DescriptionSet the drive roll pressure by Drive Roll Pressure SettingChanging the GUN Receiver bUSHING To change the gun bushingMagnum GUN and CAbLE ASSEMbLIES Welding GUNS, Torches and ACCES- SoriesGUN Receiver bUSHING To change the gear ratio Wire Feed Shut Down CircuitChanging the Gear Ratio Spindle Placement Wire Reel LoadingDIP Switch #8 Position Gear Ratio Loading 16 to 44 lb .3 20kg SpoolsUsing K1504-1 Coil Reel Figure A.10Removing a Readi-Reel Weld Wire RoutingLoading 30 lb .6 kg Readi-Reels See Figure A.11 13INSTALLATIONA-13 Shielding GAS ConnectionExAMPLES of Connecting AN Arclink Power Wave System Control bOx BOOM ConfigurationWire Drive CV Welding Pulse Welding or STT WeldingWelding Sparks can cause fire or explosion OperationFumes and Gases can be dangerous ARC Rays can burnProduct Description Definitions of Welding ModesCommon Welding AbbREVIATIONS Recommended ProcessesProcess Limitations Required EquipmentAdditional Required Equipment Equipment LimitationsFront Panel Controls and Connections Status LED Synergic CV Voltage Display Volts / Trim Display and Output KNObPrior to Welding LAYOUT-CONTROLS see Figure b.3 Mode Select Panel 4 MSP4Overview LAYOUT-DIGITAL DisplayChanging ARC Wave Control POWER-UP SequenceChanging Weld Modes Infrared IR ControlAccessing the Machine Setup Menu Limit SettingMachine SETUP/USER Preferences SET-UP Features Menu Figure b.3a Setup MenuUser Defined Parameters Parameter Definition Procedure Change Method Stall Factor AdjustmentReset Consumable Weight Parameter Definition Gun Offset AdjustmentCrater Delay TIG Gas ControlDisplay Trim as Volts Option Arc Start/Loss Error TimeDefinition Push-Pull Gun Knob behavior Sense From StudsParameter Definition Show Test Modes 100 View Diagnostics107 View Power Source Protocol 101 View Event LogsStep Trigger Operation Cold Feed / GAS Purge Switch Step / 4-STEP Trigger SwitchStep Trigger Step Trigger Operation Sequence of OperationFigure b.5 Modes Process Setup and OperationNon- Synergic Steel and Stainless Synergic GMAW-P Pulsed MIG Welding ARC ControlPulse-on-Pulse Welding Machine Functionality bY Weld Process CC Stick ModesCV GMAW/FCAW NON-SYNERGIC Process Weld ModeOutput Control KNObS, Weld Mode 5 CV NON-SYNERGIC ModesSynergic CV Modes Wire SIzE 030 035 045 052Gmaw Synergic Material Process GASPulse and PULSE-0N-PULSE Modes Wire SIzEPulse and PULSE-ON-PULSE Synergic 035 045 052 STT and STT II SynergicSTT and STT II Modes Touch Start TIG Gtaw TIG WeldingGtaw Touch Start TIG Welding All Metals Touch Start TIGDIP Switch Settings User MemoriesLow Limit Limit SettingHigh Limit AttributeAccessories OptionalAccessories Lb. coils to 2 spindles Routine Maintenance MaintenanceSafety Precautions CALIbRATION Specification1TROUbLESHOOTINGE-1 Recommended PRObLEMS POSSIbLESymptoms Cause Course of Action ErrNo Heart beat response from See what to Do on Err Error Codes for the Power Wave TROUbLESHOOTING Symptoms OtherThree Dashes PRObLEMSCause Recommended Course of Action LINC-NET System Error Codes Error CodesYour local Lincoln Authorized Arclink System Error CodesField Service Facility PRObLEMS POSSIbLE Output PRObLEMS TROUbLESHOOTING Recommended Feeder DiagramsPower Feed 10M Single Wire Diagrams 30.46 Dimension Print14.56 18.48 15.80 Precaucion Warnung