TROUbLESHOOTING | ||
|
|
|
| Observe all Safety Guidelines detailed throughout this manual |
|
|
|
|
PRObLEMS
(SYMPTOMS)
POSSIbLE
CAUSE
RECOMMENDED
COURSE OF ACTION
|
|
| ||
|
| |||
Err 006 |
| 1. The wire feeder has not received | ||
|
|
|
| a recognition command from the |
|
|
|
| power source. Verify the power |
|
|
|
| source is operating properly |
|
|
|
| (Status light steady green.) |
|
|
| 2. | Check control cable for loose or |
|
|
|
| broken leads. |
|
|
| 3. | See power source service |
|
|
|
| Manual. |
|
|
|
| |
Err 100 |
| 1. The power source has issued a | ||
|
|
|
| shutdown command. Verify the |
|
|
|
| power source is operating proper- |
|
|
|
| ly. (Status light steady green.) |
|
|
| 2. | Check control cable for loose or |
|
|
|
| broken leads. |
|
|
| 3. | See power source service |
|
|
|
| Manual. |
|
|
|
| |
|
| ARCLINK SYSTEM | ERROR CODES | |
Err 31 |
| Primary overcurrent | 1. The power source has exceeded | |
|
|
|
| input current limits. Adjust the |
|
|
|
| welding procedure to reduce the |
|
|
|
| current draw. The welding proce- |
|
|
|
| dure may exceed the capacity of |
|
|
|
| the power source. |
|
|
| 2. | See the power source service |
|
|
|
| Manual. |
|
|
|
| |
Err 32 |
| Capacitor bank "A" under | 1. The power source input power | |
|
| voltage. |
| may be wired incorrectly. Verify |
|
|
|
| the power source reconnect |
|
|
|
| panel wiring matches the input |
|
|
|
| power. |
|
|
| 2. See the power source service | |
|
|
|
| Manual. |
|
|
|
|
|
|
|
|
|
|
Check to see if the STATUS LED on the Power Wave 455 is not steady green. If it is not steady green, refer to the Power Wave 455 Status LED Chart and Code Table. Check the control cables for loose or faulty con- nections. Also check the continuity of all five leads from one end to the other. The control board in the PW 455 may be faulty.
See Err 006 in this chart.
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.