BEFORE YOU BEGIN
This column contains instructions that will be repeated throughout this manual.
PLUGGING IN THE SPRAYER
1. | Check that the ON/OFF | o |
| switch is in the OFF | |
|
| |
| position. |
|
2. | Plug the sprayer into a |
|
| heavy duty grounded |
|
| extension cord. Refer to |
|
| Important Electrical |
|
| Information, page 3). |
|
PRESSURE RELIEF PROCEDURE
WARNING
Be sure to follow the pressure relief procedure (page 6) when shutting the unit off FOR ANY PURPOSE. This procedure is used to relieve pressure from the spray hose.
1. Lock the spray gun off.
GX-06/07
GX-08/10
CHOOSING THE CORRECT SPRAY GUN FILTER
Use the proper gun filter based on the tip size being used.
Part No. | Tip Size | Filter | Mesh | Color of | Qty. |
|
| Type | Number | Filter |
|
|
|
|
| Body |
|
0154918 | .011 | Extrafine | 180 mesh | red | 2 pack |
|
|
| 0.084 mm |
|
|
|
|
|
|
|
|
0154675 | .013 | Fine | 100 mesh | yellow | 2 pack |
|
|
| 0.140 mm |
|
|
|
|
|
|
|
|
0154842 | .017 | Medium | 50 mesh | white | 2 pack |
|
|
| 0.315 mm |
|
|
|
|
|
|
|
|
BEFORE YOU PRIME THE SPRAYER
Before priming, squirt a teaspoon of separating oil (P/N 0154908 included with unit) into the indicated area. Light household oil can be substituted if necessary. Do not put more than a teaspoon into the lubricating area. Too much oil will leak down into your paint.
IF YOUR UNIT IS NEW. . .
2.Flip the ON/OFF switch to the OFF (O) position.
3.Unlock the spray gun, turn the PRIME/SPRAY knob to PRIME, and trigger spray gun into paint bucket.
4.Lock the spray gun.
o
PRIME | SPRAY |
All units are
•Whether you are going to spray latex or
IF YOUR UNIT HAS ALREADY BEEN USED. . .
If the pump has already been used you will need to purge the water or solvent used in cleanup and storage.
PAINT STRAINING
It is recommended that in order to avoid premature tip and gun clogging you should strain your paint before spraying. Follow manufacturer’s recommendations.
English | Customer Service: | © 2003 Wagner Spray Tech - All rights reserved. |
|
|
|