(3)With finger off the trigger, depress the push lever against the workpiece.
THE STAPLER MUST NOT OPERATE.
Depress Push Lever
Do not pull Trigger
(4)Without touching the trigger, depress the push lever against the workpiece. Pull the trigger.
THE STAPLER MUST OPERATE
(5)With the Stapler off the workpiece, pull the trigger. Depress the push lever against the workpiece.
THE STAPLER MUST OPERATE.
(6)If no abnormal operation is observed, you may load staples in the Stapler.
Drive staples into the workpiece that is the same type to be used in the actual application.
THE STAPLER MUST OPERATE PROPERLY.
ADJUSTING AIR PRESSURE
WARNING
● Do not exceed 120 psi (8.3 bar 8.5 kgf/cm2).
Adjust the air pressure at recommended operating pressure 70 – 120 psi (4.9 – 8.3 bar 5 – 8.5 kgf/cm2) according to the length of staples and the hardness of workpiece.
The correct air pressure is the lowest pressure which will do the job. Using the Stapler at a higher than required air pressure unnecessarily over stresses the Stapler.