DeWalt D55153R instruction manual Shut-down, Maintenance Chart, Compressor Pump Oil Change

Page 12

5135175-02,01.qxd 3/30/05 8:32 PM Page 10

English

6. Adjust the regulator to the desired setting.

NOTE: If any unusual noise or vibration is noticed, stop the com- pressor and refer to the troubleshooting section.

Shut-down

NOTE: NEVER stop the air compressor by unplugging it from the power source. This could result in damage to the unit.

1. Move the ON/OFF lever to the OFF position.

NOTE: If finished using compressor, follow steps 2 - 7 below.

2.Unplug the cord from the outlet.

3.Turn the regulator knob counterclockwise until it is fully closed. Ensure that the regulated pressure gage reads 0 PSI.

3.Remove the hose and accessory.

4.Drain the air tanks.

5.Allow the compressor to cool down.

6.Wipe compressor clean and store in a safe, non-freezing area.

Maintenance

The following procedures must be followed when maintenance or service is performed on the air compressor.

1.Turn off the compressor.

2.Disconnect cord from electrical outlet.

3.Drain tanks.

4.Allow the compressor to cool down before starting service. NOTE: All compressed air systems contain maintenance parts (e.g. lubricating oil, filters, separators) which are periodically replaced. These used parts may be, or may contain, substances that are regulated and must be disposed of in accordance with local, state, and federal laws and regulations.

NOTE: Take note of the positions and locations of parts during disassembly to make reassembly easier. The assembly sequences and parts illustrated may differ for your particular unit.

NOTE: Any service operations not included in this section should be performed by authorized service personnel.

Maintenance Chart

Procedure

Day Week Month 200 Hrs.

Check pump oil level

X

Oil leak inspection

X

Drain condensation in air tank(s)

X

Check for unusual noise/vibration

X

Check for air leaks**

X

Inspect air filter

X

Clean exterior of compressor

X

Check safety relief valve

X

Change pump oil *

X

Replace air filter

X

*The pump oil must be changed after the first 20 hours of oper- ation. Thereafter, every 200 hours or once a year, whichever comes first. In harsh environments, maintenance must be performed on an accelerated schedule. Always use DEWALT synthetic oil.

**To check for air leaks apply a solution of soapy water around joints. While the compressor is reaching the pressure cut-out limit and after the pump cuts out, look for air bubbles around the joints.

Compressor Pump Oil Change

NOTE: Pump oil contains substances that are regulated and must be disposed of in accordance with local, state, and federal laws and regulations.

WARNING : Aftercooler, pump head, and surrounding parts are very hot. Do not touch (see Hot Surfaces on page 4).

10

Image 12
Contents Guide Dutilisation Manual DE Instrucciones English Specifications Model Safety Instructions Attachments & AccessoriesAIR Tank Risk of Explosion or Fire Risk of Electrical ShockGrounding Instructions Risk from Flying Objects Risk to BreathingRisk from Moving Parts Risk of BurnsDewalt Air Compressor Features Pressure SwitchInspection of Compressor IntroductionCommon Procedures Adjusting the Regulator Installing HosesDisconnecting Hoses Checking AIR Filter ElementPreparation For Use CompatibilityLocation Operating Procedures Air Inlet Filter General RequirementsMaintenance Maintenance ChartShut-down Compressor Pump Oil ChangeFull One Year Warranty AccessoriesService RepairsTroubleshooting Guide Code Possible Cause Possible Solution English Français Pressostat Consignes de sécurité Réservoir D’AIRAccessoires Risque D’EXPLOSION OU D’INCENDIERisque DE Choc Électrique Directives Concernant LA Mise À LA TerreDiagramme DES Rallonges Risques causés par les objets projetés en lair Risques Causés PAR LA Respiration DE L’AIR CompriméInspection du compresseur Caractéristiques du compresseur d’airRisque DE Brûlures Procédures courantes Installation DU Boyau Vérification DU Fonctionnement DE LA Soupape DE SûretéVérification DE L’ÉLÉMENT DU Filtre À AIR Mise EN Marche DE L’APPAREILPréparation avant utilisation CompatibilitéPurge DU Réservoir Étapes InitialesEmplacement Filtre à airExigences générales Mode d’emploi ArrétPVC Conduite DE Vidange DE Condensat Liste DE Vérification DE PRÉ-DÉMARRAGEProgramme de maintenance EntretienAccessoires Vidange d’huile de la pompe du compresseurGarantie complète d’un an Remplacement Gratuit DE L’ÉTIQUETTE D’AVER Problème Code de problèmeGuide DE Dépannage Code Cause possible Solution possible La soupape de sûreté est défectueuse Español Regulador Instrucciones de seguridad Tanque DE AireDispositivos Y Accesorios Riesgo DE Explosión O Incendio Riesgo DE Choque EléctricoInstrucciones DE Aterrizaje Riesgo POR Objetos Voladores Riesgo RespiratorioIntroducción Riesgo DE Piezas MóvilesRiesgo DE Quemaduras Riesgos POR RuidoInspección del compresor Características del compresor de aireProcedimientos comunes Encendido DE LA Unidad Apagado DE LA UnidadAjuste DEL Regulador Instalación DE ManguerasPreparación para el uso CompatibilidadLocalización Ajuste InicialFiltro de entrada de aire Requerimientos generalesProcedimientos de operación Apagado MantenimientoEncendido Cambio de aceite de la bomba del compresor Tabla de mantenimientoAccesorios Importante Póliza de GarantíaGarantía Completa ServicioProblema Código del problema CódigoPosible causa Posible solución Código Posible causa Posible solución 5135175-02,01.qxd 3/30/05 832 PM