DeWalt D55153R Risk from Flying Objects, Risk to Breathing, Risk from Moving Parts, Risk of Burns

Page 6

5135175-02,01.qxd 3/30/05 8:32 PM Page 4

English

A GROUNDED

B

C

OUTLET

 

GROUNDING

BOX

 

 

MEANS

 

 

GROUNDING PIN

 

ADAPTER

adapter must be connected to a permanent ground such as a properly grounded outlet box.

The adapter (C) is not for use in Canada.

DEWALT does not recommend the use of extension cords. This can create power loss and overheating of the motor. Use an additional air hose rather than an extension cord. If use of an extension cord is unavoidable, it should be plugged into a GFCI found in circuit boxes or protected receptacles. When using an extension cord, observe the following.

Extension Cord Chart

1 Hp Motor

 

 

 

 

Rating

Length of Cord in Feet

 

 

25’

50’

100’

 

12 amp, 115V

14 Ga.

12 Ga.

10 Ga.

 

2 Hp Motor

 

 

 

 

Rating

Length of Cord in Feet

 

 

25’

50’

100’

 

15 amp, 115V

14 Ga.

12 Ga.

8 Ga.

 

RISK FROM FLYING OBJECTS

The compressed air stream can cause soft tissue damage to exposed skin and can propel dirt, chips, loose particles and small objects at high speed, resulting in serious injury. Always wear ANSI Z28.1 approved safety glasses with side shields when using the compressor. Never direct air stream at people or animals. Use only OSHA approved air blow guns.

RISK TO BREATHING

The compressed air from your compressor is not safe for breathing! The air stream may contain carbon monoxide, toxic

vapors or solid particles. Never inhale air from the compressor either directly or from a breathing device connected to the compressor.

Sprayed materials such as paint, paint solvents, paint remover, insecticides, weed killers, etc. contain

harmful vapors and poisons. NOTE: Operate air compressor only in a well ventilated area. Read and follow the safety instructions provided on the label or safety data sheets for the material you are spraying. Use a NIOSH/MSHA approved respirator designed for use with specific application.

RISK FROM MOVING PARTS

The compressor cycles automatically when the pressure switch is in the ON/AUTO position. Always turn off the com-

pressor, bleed pressure from the air hose and tank, and disconnect from power source before performing maintenance or attaching tools and accessories.

Keep your hair, clothing, and gloves away from moving parts. Loose clothes, jewelry, or long hair

can be caught in moving parts. Air vents may cover moving parts and should be avoided as well. Do not remove the protective covers from this product. Never operate compressor with guards or protective covers that are damaged or removed. Never stand on the compressor.

RISK OF BURNS

Touching exposed metal such as the compressor head or aftercooler can result in serious burns. Never touch any exposed metal parts on compressor during or immediately after operation. Compressor

4

Image 6
Contents Guide Dutilisation Manual DE Instrucciones English Specifications Model Safety Instructions Attachments & AccessoriesAIR Tank Risk of Explosion or Fire Risk of Electrical ShockGrounding Instructions Risk from Moving Parts Risk from Flying ObjectsRisk to Breathing Risk of BurnsInspection of Compressor Dewalt Air Compressor FeaturesPressure Switch IntroductionCommon Procedures Disconnecting Hoses Adjusting the RegulatorInstalling Hoses Checking AIR Filter ElementPreparation For Use CompatibilityLocation Operating Procedures Air Inlet Filter General RequirementsShut-down MaintenanceMaintenance Chart Compressor Pump Oil ChangeService Full One Year WarrantyAccessories RepairsTroubleshooting Guide Code Possible Cause Possible Solution English Français Pressostat Consignes de sécurité Réservoir D’AIRRisque DE Choc Électrique AccessoiresRisque D’EXPLOSION OU D’INCENDIE Directives Concernant LA Mise À LA TerreDiagramme DES Rallonges Risques causés par les objets projetés en lair Risques Causés PAR LA Respiration DE L’AIR CompriméInspection du compresseur Caractéristiques du compresseur d’airRisque DE Brûlures Procédures courantes Vérification DE L’ÉLÉMENT DU Filtre À AIR Installation DU BoyauVérification DU Fonctionnement DE LA Soupape DE Sûreté Mise EN Marche DE L’APPAREILPurge DU Réservoir Préparation avant utilisationCompatibilité Étapes InitialesEmplacement Filtre à airExigences générales PVC Conduite DE Vidange DE Condensat Mode d’emploiArrét Liste DE Vérification DE PRÉ-DÉMARRAGEProgramme de maintenance EntretienAccessoires Vidange d’huile de la pompe du compresseurGarantie complète d’un an Remplacement Gratuit DE L’ÉTIQUETTE D’AVER Problème Code de problèmeGuide DE Dépannage Code Cause possible Solution possible La soupape de sûreté est défectueuse Español Regulador Instrucciones de seguridad Tanque DE AireDispositivos Y Accesorios Riesgo DE Explosión O Incendio Riesgo DE Choque EléctricoInstrucciones DE Aterrizaje Riesgo POR Objetos Voladores Riesgo RespiratorioRiesgo DE Quemaduras IntroducciónRiesgo DE Piezas Móviles Riesgos POR RuidoInspección del compresor Características del compresor de aireProcedimientos comunes Ajuste DEL Regulador Encendido DE LA UnidadApagado DE LA Unidad Instalación DE ManguerasLocalización Preparación para el usoCompatibilidad Ajuste InicialFiltro de entrada de aire Requerimientos generalesProcedimientos de operación Apagado MantenimientoEncendido Cambio de aceite de la bomba del compresor Tabla de mantenimientoAccesorios Garantía Completa ImportantePóliza de Garantía ServicioProblema Código del problema CódigoPosible causa Posible solución Código Posible causa Posible solución 5135175-02,01.qxd 3/30/05 832 PM