Code | Possible Cause | Possible Solution | |
22 | Tank air pressure exceeds pressure switch | Set pressure switch in the “Auto” position. The motor will | |
| automatically start when air tank pressure drops below | ||
|
| pressure. | |
23 | Pressure relief valve on pressure switch has | Drain tanks. If problem persists, | |
| not unloaded pump head pressure. | contact DEWALT customer service at | |
24 | Defective motor, motor capacitor, or pressure switch. | Contact DEWALT Customer Service at | |
25 | Pressure switch does not shut off motor when | Move the pressure switch to the OFF position. | |
| air compressor reaches | If the motor does not shut off, unplug the air compressor. If the | |
|
| electrical contacts are welded together, replace the pressure | |
|
| switch. | |
26 | Air compressor is not large enough for air required. | Check accessory air requirement. If higher than the CFM or |
|
|
| pressure supply of the air compressor, then larger air compressor |
|
|
| is required. |
|
27 | Defective pressure switch. | Replace the pressure switch. |
|
28 | Defective safety relief valve. | Operate safety relief valve manually by pulling on test ring. If it | |
|
| still leaks, replace the safety relief valve. | |
29 | Excessive air tank pressure. | Defective pressure switch. Replace the pressure switch. | |
30 | Defective gaskets. | Replace and torque head bolts to 6 to 7 ft lbs. | |
31 | Fittings not tight enough. | Warning: Drain air before tightening. Tighten fittings so air can | |
|
| not be heard escaping. Check joint with soap solution. Do not | |
|
| overtighten | |
32 | Defective or rusted air tank | Air tank must be replaced. Do not attempt to repair air tank. | |
33 | Pressure regulator knob not turned to high enough | Adjust pressure regulator knob to proper setting or replace. | |
| pressure or defective pressure regulator. |
|
|
34 | Hose or hose connections are too small or too long. | Replace with larger hose or connectors. |
|
35 | Possible defective reed valve. | Remove pump head and inspect valve plate and reed valve. | |
|
| Clear or replace valves as required. | |
36 | Air compressor on uneven surface. | Do not incline the air compressor more than 10˚ in any direction | |
|
| while running. | |
37 | Crankcase overfilled with oil. | Drain oil. Refill to proper level with DEWALT synthetic oil. | |
38 | Plugged oil dipstick vent. | Clean dipstick vent. |
|
39 | Water in oil due to condensation. | Drain oil. Refill to proper level with DEWALT synthetic oil. | |
40 | Condensation in air tank caused by high level of | Drain air tank after every use. Drain air tank more often in humid |
|
| atmospheric humidity. | weather and use an air line filter. |
|
41 | Compressor located in damp or humid location. | Relocate the compressor. |
|
|
|
|
|