Porter-Cable C6110 instruction manual Know Your Air Compressor, Description of Operation

Page 11

OPERATION

Know Your Air Compressor

READ THIS OWNER’S MANUAL AND SAFETY RULES BEFORE OPERATING YOUR UNIT. Compare the illustrations with your unit to familiarize yourself with the location of various controls and adjustments. Save this manual for future reference.

 

 

 

Tank Pressure

 

 

 

Gauge

 

 

 

Outlet

 

Pressure

 

Switch

Pressure

 

 

 

Gauge

 

 

 

 

 

 

Quick

Auto (I)/

 

 

Connect

 

Off (O)

 

 

 

 

 

Switch

 

Regulator

 

 

 

 

 

 

 

 

 

Safety Valve

Description of Operation

Become familiar with these controls before operating the unit.

Auto(I)/Off(O) Switch: Place this switch in the Auto (I) position to provide automatic power to the pressure switch and Off (O) to remove power at the end of each use.

Pressure Switch: The pressure switch automatically starts the motor when the air tank pressure drops below the factory set "cut-in" pressure. It stops the motor when the air tank pressure reaches the factory set "cut-out" pressure.

Safety Valve: If the pressure switch does not shut off the air compressor at its "cut-out" pressure setting, the safety valve will protect against high pressure by "popping out" at its factory set pressure (slightly higher than the pressure switch "cut-out" setting).

Tank Pressure Gauge: The tank pressure gauge indicates the reserve air pressure in the tank.

Outlet Pressure Gauge: The outlet pressure gauge indicates the air pressure available at the outlet side of the regulator. This pressure is controlled by the regulator and is always less than or equal to the tank pressure.

Regulator: Controls the air pressure shown on the outlet pressure gauge. Pull the knob out and turn clockwise to increase pressure and counterclockwise to decrease pressure. When the desired pressure is reached push knob in to lock in place.

Cooling System (not shown): This compressor contains an advanced design cooling system. At the heart of this cooling system is an engineered fan. It is perfectly normal for this fan to blow air through the vent holes in large amounts. You know that the cooling system is working when air is being expelled.

Air Compressor Pump (not shown): Compresses air into the air tank. Working air is not available until the compressor has raised the air tank pressure above that required at the air outlet.

11-­ ENG

Image 11
Contents C6110 ModelHazard Safety Guidelines DefinitionsImportant Safety Instructions Risk to Breathing Asphyxiation What can happen How to prevent itRisk of Bursting Attachments & accessoriesRisk of Electrical Shock Tires Over inflation of tires couldResult in serious injury Property damageRisk from Moving Parts Risk from Flying Objects What can happen How to prevent itRisk of Hot surfaces Risk of Injury from Lifting Risk of Unsafe Operation What can happen How to prevent itRisk of Falling Duty Cycle Specification ChartRisk from noise What can happen How to prevent it GlossaryUnpacking AccessoriesAssembly InstallationMoving Extension CordsVoltage and Circuit Protection TransportingDescription of Operation OperationKnow Your Air Compressor Before Starting Before Each Start-Up How to StopMotor Overload Protector not shown The motor Customer Responsibilities MaintenanceHow to Start To Drain Tank To Check Safety ValveAir Filter Inspection and Replacement Air Compressor Pump Intake and Exhaust Valves Service and AdjustmentsTo Replace or Clean Check Valve To Replace Regulator StorageProblem Cause Correction ServiceTroubleshooting Replacement Parts Service and RepairsTank can rupture or explode Replace or Clean Check ValveDo not drill into, weld or otherwise Refer to Motor Overload Protection Limited WarrantyAdvertencia Avertissement Modèle C6110 Simple détapeIndique un danger Mesures DE Sécurité DéfinitionsConsignes DE Sécurité Importantes Ce qui peut se produire Comment l’Éviter Risque Repiratoire AsphyxieRisque d’Éclatement Attachements et Accessoires Et des dommages à la propriété La mise à la terre sous InstallationPneus Des pneus surgonflés pourraient Provoquer des blessures gravesPiÈces mobiles Risque associÉ auxRisque DE Chute Modèle no C6110 LexiqueRisque DE Blessure EN Soulevant LE Produit Risque associÉ au bruitAssemblage Cycle DE ServiceAccessoires Emplacement du compresseur dairProtection contre la surtension et protection du circuit RallongesLevage DéplacementTransport Description du fonctionnement UtilisationFamiliarisez-vous avec votre compresseur dair Arrêt de lappareil Utilisation de lappareilMise en marche EntretienResponsabilités du consommateur Vidange du réservoir Vérification de la soupape de sûretéRéparations ET Réglages Filtre à air Inspection et remplacementRemplacement du régulateur Remplacement ou nettoyage de la soupape de retenueRangement Problème Cause Correction DépannageEntretien ET Réparation Déclatement. Évitez de percer Remplacement ou nettoyageDe la soupape de retenue de la RisquePas assez puissant pour Garantie Limitée Pour les faire remplacer gratuitement Remarque Importante Manual de InstruccionesPeligro Definiciones DE Normas DE SeguridadInstrucciones Importantes DE Seguridad ¿Qué puede suceder? Cómo evitarlo Riesgo Respiratorio asfixiaElementos y accesorios Riesgo de explosiónDe Conexión a tierra en Instalación NeumáticosRiesgo de descarga eléctrica Riesgo por piezas móviles Riesgo DE superficies calientesRiesgo DE Caídas Riesgo de operación inseguraModelo Nº C6110 GlosarioRiesgo DE Lesión POR Levantar Mucho Peso Riesgo por ruidosInstalación Ciclo DE ServicioAccesorios EnsambladoNo Utilice UN ADAPTADOR. Vea la figura Cables de extensión eléctricaProtección del voltaje y del circuito Trasladar la Unidad TransporteLevantar la Unidad Descripción de operaciones OperaciónConozca su compresor de aire Cómo detenerla Cómo utilizar su unidadCómo poner en marcha Cómo verificar la válvula de seguridad MantenimientoResponsabilidades del cliente Filtro de Aire Inspección y reemplazo Cómo drenar el tanquePara reemplazar o limpiar la válvula de retención Servicio Y AjustesPara reemplazar el regulador Servicio AlmacenajeLa válvula de retención en la Guía DE Diagnóstico DE ProblemasProblema Causa Corrección Cómo reemplazar o limpiarSoldadura o cosa semejante RiesgoDe Explosión. No efectúe Perforación alguna sobre laSobrecalentamiento del motor Consulte Protector de67-­ SP Incidental O INDIRECTAMENTE, O Como Consecuencia DE Algún Garantía LimitadaIdentificación DEL Producto Sello o firma del Distribuidor ExcepcionesSustitución Gratuita DE LAS Etiquetas Advertencia CULIACAN, SIN Page Highway 45 North Jackson, TN