Porter-Cable C6110 Service and Adjustments, Air Compressor Pump Intake and Exhaust Valves

Page 15

If it is dirty, replace it with a new filter.

1.Using a pair of needle nose pliers or a screwdriver pull or pry out the old filter and carefully clean the filter area.

2.Push the new air filter in place.

Air Compressor Pump Intake and Exhaust Valves

Once a year have a Trained Service Technician check the air compressor pump intake and exhaust valves.

SERVICE AND ADJUSTMENTS

ALL MAINTENANCE AND REPAIR OPERATIONS NOT LISTED MUST BE PERFORMED BY TRAINED SERVICE TECHNICIAN.

Risk of Unsafe Operation. Unit cycles automatically when power is on. When servicing, you may be exposed to voltage sources, compressed air, or moving parts. Before servicing unit unplug or disconnect electrical supply to the air compressor, bleed tank of pressure, and allow the air compressor to cool.

To Replace or Clean Check Valve

 

 

 

 

 

 

1.

Release all air pressure from air tank. See To

 

Outlet

 

 

Tube

 

 

Drain Tank in the Maintenance section.

 

 

 

 

 

 

2.

Unplug air compressor.

 

 

 

3.

Using an adjustable wrench loosen outlet

 

Nut

 

tube nut at air tank and pump. Carefully

 

 

 

 

move outlet tube up away from check

 

Check

 

valve.

 

 

 

Valve

4.

Using an adjustable wrench loosen pressure

 

 

 

 

 

relief tube nut at air tank. Carefully move

 

 

 

 

pressure relief tube away from check valve.

 

 

 

5.Unscrew the check valve (turn Pressure

counterclockwise) using a 7/8" open

Relief

Nut

end wrench. Note the orientation for

Tube

reassembly.

 

 

 

 

6.Using a screwdriver, carefully push the valve disc up and down. NOTE: The valve

disc should move freely up and down on a spring which holds the valve

disc in the closed position, if not the

Screwdriver

check valve needs to be cleaned or

In open

replaced.

position

7. Clean or replace the check valve.

nothing is

A solvent, such as paint or varnish

visible.

remover can be used to clean the

In closed position

check valve.

disc is visible.

8.Apply sealant to the check valve

threads. Reinstall the check valve (turn clockwise).

9.Replace the pressure release tube. Tighten nut.

10.Replace the outlet tube and tighten nuts.

15-­ ENG

Image 15
Contents C6110 ModelSafety Guidelines Definitions Important Safety InstructionsHazard Risk to Breathing Asphyxiation What can happen How to prevent itRisk of Bursting Attachments & accessoriesRisk of Electrical Shock Tires Over inflation of tires couldResult in serious injury Property damageRisk from Flying Objects What can happen How to prevent it Risk of Hot surfacesRisk from Moving Parts Risk of Unsafe Operation What can happen How to prevent it Risk of FallingRisk of Injury from Lifting Duty Cycle Specification ChartRisk from noise What can happen How to prevent it GlossaryUnpacking AccessoriesAssembly InstallationMoving Extension CordsVoltage and Circuit Protection TransportingOperation Know Your Air CompressorDescription of Operation How to Stop Motor Overload Protector not shown The motorBefore Starting Before Each Start-Up Maintenance How to StartCustomer Responsibilities To Check Safety Valve Air Filter Inspection and ReplacementTo Drain Tank Service and Adjustments To Replace or Clean Check ValveAir Compressor Pump Intake and Exhaust Valves To Replace Regulator StorageProblem Cause Correction ServiceTroubleshooting Replacement Parts Service and RepairsReplace or Clean Check Valve Do not drill into, weld or otherwiseTank can rupture or explode Refer to Motor Overload Protection Limited WarrantyAdvertencia Avertissement Modèle C6110 Simple détapeMesures DE Sécurité Définitions Consignes DE Sécurité ImportantesIndique un danger Ce qui peut se produire Comment l’Éviter Risque Repiratoire AsphyxieRisque d’Éclatement Attachements et Accessoires Et des dommages à la propriété La mise à la terre sous InstallationPneus Des pneus surgonflés pourraient Provoquer des blessures gravesPiÈces mobiles Risque associÉ auxRisque DE Chute Modèle no C6110 LexiqueRisque DE Blessure EN Soulevant LE Produit Risque associÉ au bruitAssemblage Cycle DE ServiceAccessoires Emplacement du compresseur dairProtection contre la surtension et protection du circuit RallongesDéplacement TransportLevage Utilisation Familiarisez-vous avec votre compresseur dairDescription du fonctionnement Arrêt de lappareil Utilisation de lappareilEntretien Responsabilités du consommateurMise en marche Vidange du réservoir Vérification de la soupape de sûretéRéparations ET Réglages Filtre à air Inspection et remplacementRemplacement du régulateur Remplacement ou nettoyage de la soupape de retenueRangement Dépannage Entretien ET RéparationProblème Cause Correction Déclatement. Évitez de percer Remplacement ou nettoyageDe la soupape de retenue de la RisquePas assez puissant pour Garantie Limitée Pour les faire remplacer gratuitement Remarque Importante Manual de InstruccionesDefiniciones DE Normas DE Seguridad Instrucciones Importantes DE SeguridadPeligro ¿Qué puede suceder? Cómo evitarlo Riesgo Respiratorio asfixiaElementos y accesorios Riesgo de explosiónNeumáticos Riesgo de descarga eléctricaDe Conexión a tierra en Instalación Riesgo por piezas móviles Riesgo DE superficies calientesRiesgo DE Caídas Riesgo de operación inseguraModelo Nº C6110 GlosarioRiesgo DE Lesión POR Levantar Mucho Peso Riesgo por ruidosInstalación Ciclo DE ServicioAccesorios EnsambladoCables de extensión eléctrica Protección del voltaje y del circuitoNo Utilice UN ADAPTADOR. Vea la figura Transporte Levantar la UnidadTrasladar la Unidad Operación Conozca su compresor de aireDescripción de operaciones Cómo detenerla Cómo utilizar su unidadCómo poner en marcha Mantenimiento Responsabilidades del clienteCómo verificar la válvula de seguridad Filtro de Aire Inspección y reemplazo Cómo drenar el tanquePara reemplazar o limpiar la válvula de retención Servicio Y AjustesPara reemplazar el regulador Servicio AlmacenajeLa válvula de retención en la Guía DE Diagnóstico DE ProblemasProblema Causa Corrección Cómo reemplazar o limpiarSoldadura o cosa semejante RiesgoDe Explosión. No efectúe Perforación alguna sobre laSobrecalentamiento del motor Consulte Protector de67-­ SP Incidental O INDIRECTAMENTE, O Como Consecuencia DE Algún Garantía LimitadaIdentificación DEL Producto Sello o firma del Distribuidor ExcepcionesSustitución Gratuita DE LAS Etiquetas Advertencia CULIACAN, SIN Page Highway 45 North Jackson, TN