Know Your Air Compressor

READ THIS OWNER’S MANUAL AND SAFETY RULES BEFORE OPERATING YOUR UNIT. Compare the illustrations with your unit to familiarize yourself with the location of various controls and adjustments. Save this manual for future reference.

On(I)/Off(O) Switch

Outlet

Pressure

TankGauge

Pressure

Gauge

Quick Connect

Safety Valve Regulator

Description of Operation

Become familiar with these controls before operating the unit.

On(I)/Off(O) Switch: Place this switch in the ON (I) position to provide automatic power to the pressure switch and OFF (O) to remove power at the end of each use.

Pressure Switch (not shown): The pressure switch automatically starts the motor when the air tank pressure drops below the factory set "cut-in" pressure. It stops the motor when the air tank pressure reaches the factory set "cut-out" pressure.

Safety Valve: If the pressure switch does not shut off the air compressor at its "cut-out" pressure setting, the safety valve will protect against high pressure by "popping out" at its factory set pressure (slightly higher than the pressure switch "cut-out" setting).

Tank Pressure Gauge: The tank pressure gauge indicates the reserve air pressure in the tank.

Outlet Pressure Gauge: The outlet pressure gauge indicates the air pressure available at the outlet side of the regulator. This pressure is controlled by the regulator and is always less than or equal to the tank pressure.

Regulator: Controls the air pressure shown on the outlet pressure gauge. Turn regulator knob clockwise to increase pressure and counterclockwise to decrease pressure.

Cooling System (not shown): This compressor contains an advanced design cooling system. At the heart of this cooling system is an engineered fan. It is perfectly normal for this fan to blow air through the vent holes

in large amounts. You know that the cooling system is working when air is being expelled.

Air Compressor Pump (not shown): Compresses air into the air tank. Working air is not available until the compressor has raised the air tank pressure above that required at the air outlet.

11 - ENG

1000001703

Image 11
Contents Instruction ManualPancake Compressor Hazard Safety Guidelines DefinitionsImportant Safety Instructions Risk of Explosion or Fire What can Happen HOW to Prevent ITRisk to Breathing Asphyxiation What can Happen HOW to Prevent ITRisk of Bursting Attachments & accessoriesRisk of Electrical Shock What can Happen HOW to Prevent IT Risk of HOT Surfaces Electrical Grounding Failure toRisk from Flying Objects Risk of Unsafe Operation Risk from Moving Parts What can Happen HOW to Prevent ITRisk of Falling Risk from Noise What can Happen HOW to Prevent ITDuty Cycle SpecificationsAccessories GlossaryLocation of the Air Compressor AssemblyInstallation UnpackingVoltage and Circuit Protection Extension CordsDescription of Operation OperationKnow Your Air Compressor Before Each Start-Up How to StartHow to Stop Before StartingTo Drain Tank MaintenanceTo Check Safety Valve Customer ResponsibilitiesTo Replace Regulator Service and AdjustmentsTo Replace or Clean Check Valve Regulator Manifold StorageHose Clamp Regulator Manifold Pump Mounting ScrewReplacement Parts ServiceProblem Cause Correction TroubleshootingProblem Cause Correction Problem Cause Correction Limited Warranty Manuel d’instructions Compresseur de type aplati CE QUI Peut SE Produire Comment L’ÉVITER Mesures DE Sécurité DéfinitionsConsignes DE Sécurité Importantes Risque D’EXPLOSION OU D’INCENDIERisque Repiratoire Asphyxie Risque D’ÉCLATEMENT AccessoiresRisque DE Choc Électrique Les protecteurs ou les couvercles sont Risque Associé AU Bruit Risque DE ChuteModèle no Cycle DE ServiceAccessoires LexiqueDirectives DE Mise À LA Terre Emplacement du compresseur dairAssemblage DéballageProtection contre la surtension et protection du circuit RallongesFamiliarisez-vous avec votre compresseur dair UtilisationAvant chaque mise en marche Utilisation de lappareilArrêt de lappareil Avant le démarrageVidange du réservoir EntretienResponsabilités du client Vérification de la soupape de sûretéCollier du boyau Soupape de retenue Remplacement ou nettoyage de la soupape de retenueEntretien ET Réglages Pour remplacer le régulateuVis de fixation de la pompe RangementEntretien ET Réparation Pièces DE RechangeFaçon. Celui-ci risquerait DépannageProblème Cause Correction Ne Pas Trop SerrerRemarque Ajustez la Le moteur ne tourne pas Responsabilité DE Lacheteur Dorigine utilisateur initial Garantie LimitéeImportante Manual de Instrucciones Compresores con tanque Plano¿QUÉ Puede SUCEDER? Cómo Evitarlo Definiciones DE Normas DE SeguridadInstrucciones Importantes DE Seguridad Riesgo DE Explosión O IncendioRiesgo Respiratorio Asfixia Elementos y accesorios Riesgo DE ExplosiónPuede provocar lesiones en los Riesgo DE Objetos DespedidosRiesgo POR Piezas Móviles Riesgo POR Ruidos Riesgo DE CaídasAccesorios EspecificacionesGlosario Ciclo DE ServicioInstrucciones Para Conectar a Tierra EnsamblajeInstalación DesempaqueProtección del voltaje y del circuito Cables de extensión eléctricaDescripción de operaciones OperaciónConozca su compresor de aire Antes de poner en marcha Cómo utilizar su unidadCómo drenar el tanque MantenimientoResponsabilidades del cliente Cómo verificar la válvula de seguridadPara reemplazar el regulador Servicio Y AjustesPara reemplazar o limpiar la válvula retención Riesgo de Explosión. El agua AlmacenajeTornillo para montaje de la bomba Mantenimiento Y Reparaciones Guía DE Diagnóstico DE ProblemasServicio Piezas DE RepuestoEl tanque de aire, ello Riesgo de ExplosiónNo efectúe perforación Cosa semejante sobreEn caso de necesidad Garantía Limitada Highway 45 North Jackson, TN