To Replace or Clean Check Valve

1.Release all air pressure from air tank. See "To Drain Tank" in the Maintenance section.

2.Unplug unit.

3.Remove the hose by removing the hose clamp. NOTE: The hose clamp is not reusable. You must purchase a new hose clamp, see the Parts List Manual or purchase a standard hose clamp at a local hardware store.

Hose Clamp

Check

Valve

4.Unscrew the check valve (turn counter-clockwise) using a socket wrench.

5.Make sure the valve disc moves freely inside the check valve and the spring holds the disc in the upper, closed position. The check valve may be cleaned with a solvent, such as paint and varnish remover.

6.Apply sealant to the check valve threads. Reinstall the check valve (turn clockwise).

7.Replace hose and new hose clamp.

8.Perform the Break-in Procedure. See "Break-in Procedure" in the Operation section.

To Replace Regulator

1.Release all air pressure from air tank. See "To Drain Tank" in the Maintenance section.

2.Unplug unit.

3.Using an adjustable wrench or specified wrench remove the gauges (7/16" wrench), quick connect (13/16" wrench), and safety valve (9/16" wrench) from the regulator manifold.

Gauges

Safety

 

Quick

Valve

Regulator

Connect

 

Manifold

 

 

 

1000001703

14 - ENG

Image 14
Contents Instruction ManualPancake Compressor Risk of Explosion or Fire What can Happen HOW to Prevent IT Safety Guidelines DefinitionsImportant Safety Instructions HazardWhat can Happen HOW to Prevent IT Risk to Breathing AsphyxiationRisk of Bursting Attachments & accessoriesRisk of Electrical Shock What can Happen HOW to Prevent IT Risk of HOT Surfaces Electrical Grounding Failure toRisk from Flying Objects Risk from Moving Parts What can Happen HOW to Prevent IT Risk of Unsafe OperationRisk from Noise What can Happen HOW to Prevent IT Risk of FallingGlossary SpecificationsAccessories Duty CycleUnpacking AssemblyInstallation Location of the Air CompressorExtension Cords Voltage and Circuit ProtectionDescription of Operation OperationKnow Your Air Compressor Before Starting How to StartHow to Stop Before Each Start-UpCustomer Responsibilities MaintenanceTo Check Safety Valve To Drain TankTo Replace Regulator Service and AdjustmentsTo Replace or Clean Check Valve Pump Mounting Screw StorageHose Clamp Regulator Manifold Regulator ManifoldService Replacement PartsTroubleshooting Problem Cause CorrectionProblem Cause Correction Problem Cause Correction Limited Warranty Manuel d’instructions Compresseur de type aplati Risque D’EXPLOSION OU D’INCENDIE Mesures DE Sécurité DéfinitionsConsignes DE Sécurité Importantes CE QUI Peut SE Produire Comment L’ÉVITERRisque Repiratoire Asphyxie Accessoires Risque D’ÉCLATEMENTRisque DE Choc Électrique Les protecteurs ou les couvercles sont Risque DE Chute Risque Associé AU BruitLexique Cycle DE ServiceAccessoires Modèle noDéballage Emplacement du compresseur dairAssemblage Directives DE Mise À LA TerreRallonges Protection contre la surtension et protection du circuitUtilisation Familiarisez-vous avec votre compresseur dairAvant le démarrage Utilisation de lappareilArrêt de lappareil Avant chaque mise en marcheVérification de la soupape de sûreté EntretienResponsabilités du client Vidange du réservoirPour remplacer le régulateu Remplacement ou nettoyage de la soupape de retenueEntretien ET Réglages Collier du boyau Soupape de retenueRangement Vis de fixation de la pompePièces DE Rechange Entretien ET RéparationNe Pas Trop Serrer DépannageProblème Cause Correction Façon. Celui-ci risqueraitRemarque Ajustez la Le moteur ne tourne pas Garantie Limitée Responsabilité DE Lacheteur Dorigine utilisateur initialManual de Instrucciones Compresores con tanque Plano ImportanteRiesgo DE Explosión O Incendio Definiciones DE Normas DE SeguridadInstrucciones Importantes DE Seguridad ¿QUÉ Puede SUCEDER? Cómo EvitarloRiesgo Respiratorio Asfixia Riesgo DE Explosión Elementos y accesoriosRiesgo DE Objetos Despedidos Puede provocar lesiones en losRiesgo POR Piezas Móviles Riesgo DE Caídas Riesgo POR RuidosCiclo DE Servicio EspecificacionesGlosario AccesoriosDesempaque EnsamblajeInstalación Instrucciones Para Conectar a TierraCables de extensión eléctrica Protección del voltaje y del circuitoDescripción de operaciones OperaciónConozca su compresor de aire Cómo utilizar su unidad Antes de poner en marchaCómo verificar la válvula de seguridad MantenimientoResponsabilidades del cliente Cómo drenar el tanquePara reemplazar el regulador Servicio Y AjustesPara reemplazar o limpiar la válvula retención Riesgo de Explosión. El agua AlmacenajeTornillo para montaje de la bomba Piezas DE Repuesto Guía DE Diagnóstico DE ProblemasServicio Mantenimiento Y ReparacionesCosa semejante sobre Riesgo de ExplosiónNo efectúe perforación El tanque de aire, elloEn caso de necesidad Garantía Limitada Highway 45 North Jackson, TN