Porter-Cable 1000001703 Maintenance, Customer Responsibilities, To Check Safety Valve

Page 13

 

 

MAINTENANCE

 

Customer Responsibilities

 

 

 

 

 

 

 

Before each use

Daily or after each

 

 

 

 

use

 

 

 

 

 

 

 

Check Safety Valve

 

 

 

 

 

 

 

 

Drain Tank

 

 

 

 

 

 

 

Unit cycles automatically when

power is on. When performing maintenance, you may be exposed to voltage sources, compressed air, or moving parts. Personal injuries can occur. Before performing any maintenance or repair, disconnect power source from the compressor and bleed off all air pressure.

NOTE: See "Operation" section for the location of controls.

To Check Safety Valve

If the safety valve does not work

properly, over-pressurization may occur, causing air tank rupture or an explosion.

1.Before starting compressor, pull the ring on the safety valve to make sure that the safety valve operates freely. If the valve

is stuck or does not operate smoothly, it must be replaced with the same type of valve.

To Drain Tank

1.Set the On/Off switch to OFF (O).

2.Turn the regulator knob counter- clockwise to set the outlet pres- sure to zero.

3.Remove the air tool or accessory.

4.Pull ring on safety valve allowing air to bleed from the tank until tank pressure is approximately 20 psi. Release safety valve ring.

5.Drain water from air tank by opening drain valve on bottom of tank.

Water will condense in the air tank. If

not drained, water will corrode and weaken the air tank causing a risk of air tank rupture.

6.After the water has been drained, close the drain valve. The air compressor can now be stored.

NOTE: If drain valve is plugged, release all air pressure. The valve can then be removed, cleaned, the reinstalled.

13 - ENG

1000001703

Image 13
Contents Instruction ManualPancake Compressor Important Safety Instructions Safety Guidelines DefinitionsRisk of Explosion or Fire What can Happen HOW to Prevent IT HazardRisk to Breathing Asphyxiation What can Happen HOW to Prevent ITRisk of Electrical Shock What can Happen HOW to Prevent IT Attachments & accessoriesRisk of Bursting Risk from Flying Objects Electrical Grounding Failure toRisk of HOT Surfaces Risk of Unsafe Operation Risk from Moving Parts What can Happen HOW to Prevent ITRisk of Falling Risk from Noise What can Happen HOW to Prevent ITAccessories SpecificationsGlossary Duty CycleInstallation AssemblyUnpacking Location of the Air CompressorVoltage and Circuit Protection Extension CordsKnow Your Air Compressor OperationDescription of Operation How to Stop How to StartBefore Starting Before Each Start-UpTo Check Safety Valve MaintenanceCustomer Responsibilities To Drain TankTo Replace or Clean Check Valve Service and AdjustmentsTo Replace Regulator Hose Clamp Regulator Manifold StoragePump Mounting Screw Regulator ManifoldReplacement Parts ServiceProblem Cause Correction TroubleshootingProblem Cause Correction Problem Cause Correction Limited Warranty Manuel d’instructions Compresseur de type aplati Consignes DE Sécurité Importantes Mesures DE Sécurité DéfinitionsRisque D’EXPLOSION OU D’INCENDIE CE QUI Peut SE Produire Comment L’ÉVITERRisque Repiratoire Asphyxie Risque D’ÉCLATEMENT AccessoiresRisque DE Choc Électrique Les protecteurs ou les couvercles sont Risque Associé AU Bruit Risque DE ChuteAccessoires Cycle DE ServiceLexique Modèle noAssemblage Emplacement du compresseur dairDéballage Directives DE Mise À LA TerreProtection contre la surtension et protection du circuit RallongesFamiliarisez-vous avec votre compresseur dair UtilisationArrêt de lappareil Utilisation de lappareilAvant le démarrage Avant chaque mise en marcheResponsabilités du client EntretienVérification de la soupape de sûreté Vidange du réservoirEntretien ET Réglages Remplacement ou nettoyage de la soupape de retenuePour remplacer le régulateu Collier du boyau Soupape de retenueVis de fixation de la pompe RangementEntretien ET Réparation Pièces DE RechangeProblème Cause Correction DépannageNe Pas Trop Serrer Façon. Celui-ci risqueraitRemarque Ajustez la Le moteur ne tourne pas Responsabilité DE Lacheteur Dorigine utilisateur initial Garantie LimitéeImportante Manual de Instrucciones Compresores con tanque PlanoInstrucciones Importantes DE Seguridad Definiciones DE Normas DE SeguridadRiesgo DE Explosión O Incendio ¿QUÉ Puede SUCEDER? Cómo EvitarloRiesgo Respiratorio Asfixia Elementos y accesorios Riesgo DE ExplosiónPuede provocar lesiones en los Riesgo DE Objetos DespedidosRiesgo POR Piezas Móviles Riesgo POR Ruidos Riesgo DE CaídasGlosario EspecificacionesCiclo DE Servicio AccesoriosInstalación EnsamblajeDesempaque Instrucciones Para Conectar a TierraProtección del voltaje y del circuito Cables de extensión eléctricaConozca su compresor de aire OperaciónDescripción de operaciones Antes de poner en marcha Cómo utilizar su unidadResponsabilidades del cliente MantenimientoCómo verificar la válvula de seguridad Cómo drenar el tanquePara reemplazar o limpiar la válvula retención Servicio Y AjustesPara reemplazar el regulador Tornillo para montaje de la bomba AlmacenajeRiesgo de Explosión. El agua Servicio Guía DE Diagnóstico DE ProblemasPiezas DE Repuesto Mantenimiento Y ReparacionesNo efectúe perforación Riesgo de ExplosiónCosa semejante sobre El tanque de aire, elloEn caso de necesidad Garantía Limitada Highway 45 North Jackson, TN