Porter-Cable 1000001703 Electrical Grounding Failure to, Risk from Flying Objects

Page 5

 

• Repairs attempted by unqualified

• Any electrical wiring or repairs

 

personnel can result in serious

required on this product should be

 

injury or death by electrocution.

performed by authorized service

 

 

 

 

 

 

 

center personnell in accordance

 

 

 

 

 

 

 

with national and local electrical

 

 

 

 

 

 

 

codes.

 

Electrical Grounding: Failure to

• Make certain that the electrical

 

provide adequate grounding to

circuit to which the compressor

 

this product could result in serious

is connected provides proper

 

injury or death from electrocution.

electrical grounding, correct voltage

 

Refer to "Grounding Instructions"

and adequate fuse protection.

 

paragraph in the "Installation"

 

 

section.

 

 

 

 

 

 

 

HAZARD

 

 

 

 

 

 

RISK FROM FLYING OBJECTS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WHAT CAN HAPPEN

HOW TO PREVENT IT

 

• The compressed air stream can

• Always wear certified safety equip-

 

cause soft tissue damage to

ment: ANSI Z87.1 eye protection

 

exposed skin and can propel dirt,

(CAN/CSA Z94.3) with side shields

 

chips, loose particles, and small

when using the compressor.

 

objects at high speed, resulting in

• Never point any nozzle or sprayer

 

property damage or personal injury.

toward any part of the body or at

 

 

 

 

 

 

 

other people or animals.

 

 

 

 

 

 

 

• Always turn the compressor off

 

 

 

 

 

 

 

and bleed pressure from the air

 

 

 

 

 

 

 

hose and air tank before attempt-

 

 

 

 

 

 

 

ing maintenance, attaching tools or

 

 

 

 

 

 

 

accessories.

 

 

 

 

 

 

HAZARD

 

 

 

 

 

 

 

 

 

 

 

 

 

RISK OF HOT SURFACES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WHAT CAN HAPPEN

HOW TO PREVENT IT

 

• Touching exposed metal such as

• Never touch any exposed metal

 

the compressor head, engine head,

parts on compressor during or

 

engine exhaust or outlet tubes, can

immediately after operation.

 

result in serious burns.

Compressor will remain hot for

 

 

 

 

 

 

 

several minutes after operation.

 

 

 

 

 

 

 

• Do not reach around protective

 

 

 

 

 

 

 

shrouds or attempt maintenance

 

 

 

 

 

 

 

until unit has been allowed to cool.

5 - ENG

1000001703

Image 5
Contents Instruction ManualPancake Compressor Important Safety Instructions Safety Guidelines Definitions Risk of Explosion or Fire What can Happen HOW to Prevent IT HazardRisk to Breathing Asphyxiation What can Happen HOW to Prevent ITRisk of Bursting Attachments & accessoriesRisk of Electrical Shock What can Happen HOW to Prevent IT Risk of HOT Surfaces Electrical Grounding Failure toRisk from Flying Objects Risk of Unsafe Operation Risk from Moving Parts What can Happen HOW to Prevent ITRisk of Falling Risk from Noise What can Happen HOW to Prevent ITAccessories SpecificationsGlossary Duty CycleInstallation AssemblyUnpacking Location of the Air CompressorVoltage and Circuit Protection Extension CordsDescription of Operation OperationKnow Your Air Compressor How to Stop How to StartBefore Starting Before Each Start-UpTo Check Safety Valve MaintenanceCustomer Responsibilities To Drain TankTo Replace Regulator Service and AdjustmentsTo Replace or Clean Check Valve Hose Clamp Regulator Manifold StoragePump Mounting Screw Regulator ManifoldReplacement Parts ServiceProblem Cause Correction TroubleshootingProblem Cause Correction Problem Cause Correction Limited Warranty Manuel d’instructions Compresseur de type aplati Consignes DE Sécurité Importantes Mesures DE Sécurité DéfinitionsRisque D’EXPLOSION OU D’INCENDIE CE QUI Peut SE Produire Comment L’ÉVITERRisque Repiratoire Asphyxie Risque D’ÉCLATEMENT AccessoiresRisque DE Choc Électrique Les protecteurs ou les couvercles sont Risque Associé AU Bruit Risque DE ChuteAccessoires Cycle DE ServiceLexique Modèle noAssemblage Emplacement du compresseur dairDéballage Directives DE Mise À LA TerreProtection contre la surtension et protection du circuit RallongesFamiliarisez-vous avec votre compresseur dair UtilisationArrêt de lappareil Utilisation de lappareilAvant le démarrage Avant chaque mise en marcheResponsabilités du client EntretienVérification de la soupape de sûreté Vidange du réservoirEntretien ET Réglages Remplacement ou nettoyage de la soupape de retenuePour remplacer le régulateu Collier du boyau Soupape de retenueVis de fixation de la pompe RangementEntretien ET Réparation Pièces DE RechangeProblème Cause Correction DépannageNe Pas Trop Serrer Façon. Celui-ci risqueraitRemarque Ajustez la Le moteur ne tourne pas Responsabilité DE Lacheteur Dorigine utilisateur initial Garantie LimitéeImportante Manual de Instrucciones Compresores con tanque PlanoInstrucciones Importantes DE Seguridad Definiciones DE Normas DE SeguridadRiesgo DE Explosión O Incendio ¿QUÉ Puede SUCEDER? Cómo EvitarloRiesgo Respiratorio Asfixia Elementos y accesorios Riesgo DE ExplosiónPuede provocar lesiones en los Riesgo DE Objetos DespedidosRiesgo POR Piezas Móviles Riesgo POR Ruidos Riesgo DE CaídasGlosario EspecificacionesCiclo DE Servicio AccesoriosInstalación EnsamblajeDesempaque Instrucciones Para Conectar a TierraProtección del voltaje y del circuito Cables de extensión eléctricaDescripción de operaciones OperaciónConozca su compresor de aire Antes de poner en marcha Cómo utilizar su unidadResponsabilidades del cliente MantenimientoCómo verificar la válvula de seguridad Cómo drenar el tanquePara reemplazar el regulador Servicio Y AjustesPara reemplazar o limpiar la válvula retención Riesgo de Explosión. El agua AlmacenajeTornillo para montaje de la bomba Servicio Guía DE Diagnóstico DE ProblemasPiezas DE Repuesto Mantenimiento Y ReparacionesNo efectúe perforación Riesgo de ExplosiónCosa semejante sobre El tanque de aire, elloEn caso de necesidad Garantía Limitada Highway 45 North Jackson, TN