Porter-Cable 1000001703 Assembly, Installation, Unpacking, Location of the Air Compressor

Page 9

ASSEMBLY

Unpacking

1.Remove unit from carton and discard all packaging.

INSTALLATION

HOW TO SET UP YOUR UNIT

Location of the Air Compressor

Locate the air compressor in a clean, dry and well ventilated area.

The air compressor should be located at least 12" away from the wall or other obstructions that will interfere with the flow of air.

The air compressor pump and shroud are designed to allow for proper cooling. The ventilation openings on the compressor are necessary to maintain proper operating temperature. Do not place rags or other containers on or near these openings.

GROUNDING INSTRUCTIONS

Risk of Electrical Shock. In the

event of a short circuit, grounding reduces the risk of shock by providing an escape wire for

the electric current. This air compressor must be properly grounded.

The portable air compressor is equipped with a cord having a grounding wire with an appropriate grounding plug (see following illustrations).

1.The cord set and plug with this unit contains a grounding pin. This plug MUST be used with a grounded outlet.

IMPORTANT: The outlet being used must be installed and grounded in accordance with all local codes and ordinances.

2.Make sure the outlet being used has the same configuration as the grounded plug. DO NOT USE AN ADAPTER. See illustration.

3.Inspect the plug and cord before each use. Do not use if there are signs of damage.

Plug

Grounded

Outlets

Grounding Pin

4.If these grounding instructions are not completely understood, or if in doubt as to whether the compressor is properly grounded, have the installation checked by a qualified electrician.

Risk of Electrical Shock.

IMPROPER GROUNDING CAN RESULT IN ELECTRICAL SHOCK. Do not modify the plug provided. If it does not fit the available outlet, a correct outlet should be installed by a qualified electrician.

Repairs to the cord set or plug MUST be made by a qualified electrician.

9 - ENG

1000001703

Image 9
Contents Instruction ManualPancake Compressor Important Safety Instructions Safety Guidelines DefinitionsRisk of Explosion or Fire What can Happen HOW to Prevent IT HazardRisk to Breathing Asphyxiation What can Happen HOW to Prevent ITAttachments & accessories Risk of Electrical Shock What can Happen HOW to Prevent ITRisk of Bursting Electrical Grounding Failure to Risk from Flying ObjectsRisk of HOT Surfaces Risk of Unsafe Operation Risk from Moving Parts What can Happen HOW to Prevent ITRisk of Falling Risk from Noise What can Happen HOW to Prevent ITAccessories SpecificationsGlossary Duty CycleInstallation AssemblyUnpacking Location of the Air CompressorVoltage and Circuit Protection Extension CordsOperation Know Your Air CompressorDescription of Operation How to Stop How to StartBefore Starting Before Each Start-UpTo Check Safety Valve MaintenanceCustomer Responsibilities To Drain TankService and Adjustments To Replace or Clean Check ValveTo Replace Regulator Hose Clamp Regulator Manifold StoragePump Mounting Screw Regulator ManifoldReplacement Parts ServiceProblem Cause Correction TroubleshootingProblem Cause Correction Problem Cause Correction Limited Warranty Manuel d’instructions Compresseur de type aplati Consignes DE Sécurité Importantes Mesures DE Sécurité DéfinitionsRisque D’EXPLOSION OU D’INCENDIE CE QUI Peut SE Produire Comment L’ÉVITERRisque Repiratoire Asphyxie Risque D’ÉCLATEMENT AccessoiresRisque DE Choc Électrique Les protecteurs ou les couvercles sont Risque Associé AU Bruit Risque DE ChuteAccessoires Cycle DE ServiceLexique Modèle noAssemblage Emplacement du compresseur dairDéballage Directives DE Mise À LA TerreProtection contre la surtension et protection du circuit RallongesFamiliarisez-vous avec votre compresseur dair UtilisationArrêt de lappareil Utilisation de lappareilAvant le démarrage Avant chaque mise en marcheResponsabilités du client EntretienVérification de la soupape de sûreté Vidange du réservoirEntretien ET Réglages Remplacement ou nettoyage de la soupape de retenuePour remplacer le régulateu Collier du boyau Soupape de retenueVis de fixation de la pompe RangementEntretien ET Réparation Pièces DE RechangeProblème Cause Correction DépannageNe Pas Trop Serrer Façon. Celui-ci risqueraitRemarque Ajustez la Le moteur ne tourne pas Responsabilité DE Lacheteur Dorigine utilisateur initial Garantie LimitéeImportante Manual de Instrucciones Compresores con tanque PlanoInstrucciones Importantes DE Seguridad Definiciones DE Normas DE SeguridadRiesgo DE Explosión O Incendio ¿QUÉ Puede SUCEDER? Cómo EvitarloRiesgo Respiratorio Asfixia Elementos y accesorios Riesgo DE ExplosiónPuede provocar lesiones en los Riesgo DE Objetos DespedidosRiesgo POR Piezas Móviles Riesgo POR Ruidos Riesgo DE CaídasGlosario EspecificacionesCiclo DE Servicio AccesoriosInstalación EnsamblajeDesempaque Instrucciones Para Conectar a TierraProtección del voltaje y del circuito Cables de extensión eléctricaOperación Conozca su compresor de aireDescripción de operaciones Antes de poner en marcha Cómo utilizar su unidadResponsabilidades del cliente MantenimientoCómo verificar la válvula de seguridad Cómo drenar el tanqueServicio Y Ajustes Para reemplazar o limpiar la válvula retenciónPara reemplazar el regulador Almacenaje Tornillo para montaje de la bombaRiesgo de Explosión. El agua Servicio Guía DE Diagnóstico DE ProblemasPiezas DE Repuesto Mantenimiento Y ReparacionesNo efectúe perforación Riesgo de ExplosiónCosa semejante sobre El tanque de aire, elloEn caso de necesidad Garantía Limitada Highway 45 North Jackson, TN