PROBLEM | CAUSE | CORRECTION | |
|
|
| |
Pressure reading on | It is normal for "some" | If there is an | |
the regulated pressure | pressure drop to occur. | excessive amount | |
gauge drops when an |
| of pressure drop | |
accessory is used. |
| when the accessory | |
|
| is used, adjust the | |
|
| regulator following | |
|
| the instructions in | |
|
| the "Description of | |
|
| Operation" paragraph in | |
|
| the "Operation Section. | |
|
| NOTE: Adjust the | |
|
| regulated pressure | |
|
| under flow conditions | |
|
| (while accessory is | |
|
| being used). | |
|
|
| |
Compressor is not | Prolonged excessive | Decrease amount of air | |
supplying enough air to | use of air. | usage. | |
operate accessories. |
|
| |
Compressor is not | Check the accessory | ||
| |||
| large enough for air | air requirement. If it is | |
| requirement. | higher than the SCFM | |
|
| or pressure supplied | |
|
| by your air compressor, | |
|
| you need a larger | |
|
| compressor. | |
|
|
| |
| Hole in hose. | Check and replace if | |
|
| required. | |
|
|
| |
| Check valve restricted. | Remove and clean, or | |
|
| replace. | |
|
|
| |
| Air leaks. | Tighten fittings. | |
|
|
| |
Regulator knob has | Damaged regulator. | Replace. | |
continuous air leak. |
|
| |
|
|
| |
Regulator will not shut | Damaged regulator. | Replace. | |
off air outlet. |
|
| |
|
|
|