Porter-Cable 1000001703 Before Starting, Before Each Start-Up, How to Start, How to Stop

Page 12
Drain
Valve

Drain Valve: The drain valve is located at

the base of the air tank and is

used to drain

condensation at the end of each use.

Check Valve: When the air compressor is operating, the check valve is "open", allowing compressed air to enter the air tank. When the air compressor reaches "cut-out" pressure, the check valve "closes", allowing air pressure to remain inside the air tank.

Check Valve

How to Use Your Unit

How to Stop:

1.Set the On/Off switch to OFF (O).

Before Starting

Break-in Procedure

Risk of Unsafe Operation.

Serious damage may result if the following break-in instructions are not closely followed.

This procedure is required before the air compressor is put into service and when the check valve or a complete compressor pump has been replaced.

1.Make sure the On/Off switch is in the OFF (O) position.

2.Plug the power cord into the correct branch circuit receptacle. (Refer to Voltage and Circuit Protection paragraph in the Installation section of this manual.)

3.Open the drain valve (counter- clockwise) fully to permit air to escape and prevent air pressure

build up in the air tank during the break-in period.

4.Move the On/Off switch to ON (I) position. The compressor will start.

5.Run the compressor for 15 minutes. Make sure the drain valve is open and there is minimal air pressure build-up in tank.

6.After 15 minutes, close the drain valve by turning clockwise. The air receiver will fill to "cut-out" pressure and the motor will stop.

The compressor is now ready for use.

Before Each Start-Up:

1.Set the On/Off switch to OFF (O).

2.Turn the regulator knob counter- clockwise to set the outlet pres- sure to zero.

3.Attach hose and accessories. NOTE: The hose or accessory will require a quick connect plug if the air outlet is equipped with a quick connect socket.

Risk of Bursting. Too much air

pressure causes a hazardous risk of bursting. Check the manufacturer’s maximum pressure rating for air tools and accessories. The regulator outlet pressure must never exceed the maximum pressure rating.

How to Start:

1.Set the On/Off switch to ON (I) and allow tank pressure to build. Motor will stop when tank pres- sure reaches "cut-out" pressure.

2.Turn regulator knob clockwise to

increase pressure and stop when desired pressure is reached.

The compressor is ready for use.

1000001703

12 - ENG

Image 12
Contents Instruction ManualPancake Compressor Safety Guidelines Definitions Important Safety InstructionsRisk of Explosion or Fire What can Happen HOW to Prevent IT HazardWhat can Happen HOW to Prevent IT Risk to Breathing AsphyxiationAttachments & accessories Risk of Electrical Shock What can Happen HOW to Prevent ITRisk of Bursting Electrical Grounding Failure to Risk from Flying ObjectsRisk of HOT Surfaces Risk from Moving Parts What can Happen HOW to Prevent IT Risk of Unsafe OperationRisk from Noise What can Happen HOW to Prevent IT Risk of FallingSpecifications AccessoriesGlossary Duty CycleAssembly InstallationUnpacking Location of the Air CompressorExtension Cords Voltage and Circuit ProtectionOperation Know Your Air CompressorDescription of Operation How to Start How to StopBefore Starting Before Each Start-UpMaintenance To Check Safety ValveCustomer Responsibilities To Drain TankService and Adjustments To Replace or Clean Check ValveTo Replace Regulator Storage Hose Clamp Regulator ManifoldPump Mounting Screw Regulator ManifoldService Replacement PartsTroubleshooting Problem Cause CorrectionProblem Cause Correction Problem Cause Correction Limited Warranty Manuel d’instructions Compresseur de type aplati Mesures DE Sécurité Définitions Consignes DE Sécurité ImportantesRisque D’EXPLOSION OU D’INCENDIE CE QUI Peut SE Produire Comment L’ÉVITERRisque Repiratoire Asphyxie Accessoires Risque D’ÉCLATEMENTRisque DE Choc Électrique Les protecteurs ou les couvercles sont Risque DE Chute Risque Associé AU BruitCycle DE Service AccessoiresLexique Modèle noEmplacement du compresseur dair AssemblageDéballage Directives DE Mise À LA TerreRallonges Protection contre la surtension et protection du circuitUtilisation Familiarisez-vous avec votre compresseur dairUtilisation de lappareil Arrêt de lappareilAvant le démarrage Avant chaque mise en marcheEntretien Responsabilités du clientVérification de la soupape de sûreté Vidange du réservoirRemplacement ou nettoyage de la soupape de retenue Entretien ET RéglagesPour remplacer le régulateu Collier du boyau Soupape de retenueRangement Vis de fixation de la pompePièces DE Rechange Entretien ET RéparationDépannage Problème Cause CorrectionNe Pas Trop Serrer Façon. Celui-ci risqueraitRemarque Ajustez la Le moteur ne tourne pas Garantie Limitée Responsabilité DE Lacheteur Dorigine utilisateur initialManual de Instrucciones Compresores con tanque Plano ImportanteDefiniciones DE Normas DE Seguridad Instrucciones Importantes DE SeguridadRiesgo DE Explosión O Incendio ¿QUÉ Puede SUCEDER? Cómo EvitarloRiesgo Respiratorio Asfixia Riesgo DE Explosión Elementos y accesoriosRiesgo DE Objetos Despedidos Puede provocar lesiones en losRiesgo POR Piezas Móviles Riesgo DE Caídas Riesgo POR RuidosEspecificaciones GlosarioCiclo DE Servicio AccesoriosEnsamblaje InstalaciónDesempaque Instrucciones Para Conectar a TierraCables de extensión eléctrica Protección del voltaje y del circuitoOperación Conozca su compresor de aireDescripción de operaciones Cómo utilizar su unidad Antes de poner en marchaMantenimiento Responsabilidades del clienteCómo verificar la válvula de seguridad Cómo drenar el tanqueServicio Y Ajustes Para reemplazar o limpiar la válvula retenciónPara reemplazar el regulador Almacenaje Tornillo para montaje de la bombaRiesgo de Explosión. El agua Guía DE Diagnóstico DE Problemas ServicioPiezas DE Repuesto Mantenimiento Y ReparacionesRiesgo de Explosión No efectúe perforaciónCosa semejante sobre El tanque de aire, elloEn caso de necesidad Garantía Limitada Highway 45 North Jackson, TN