Moving

The wheels and handle do not provide adequate clearance, stability, or support for pulling the unit up and down stairs or steps. The unit must be lifted or pushed up a ramp.

1. Grasp handle of compressor and tilt compressor back to rest on wheels.

Risk of Unsafe Operation. Ensure proper footing and use caution when rolling compressor so that unit does not tip or cause loss of balance.

2.When location is reached slowly lower compressor to ground. Always store compressor in a vertical position resting on the rubber bumpers and wheels.

Preparation For Use

Do not operate this unit until you read this instruction manual for safety, operation and maintenance instructions.

Pre-Start Checklist (Fig. 1)

1.Ensure the On/Off switch (A) is in the OFF position.

2.Plug the power cord into the correct branch circuit receptacle. See Voltage and Circuit Protection under Installation.

3.Ensure air tank is drained, see Draining Air Tank under Maintenance.

4.Ensure the drain valve (H) is closed.

5.Ensure safety valve (G) is functioning properly, see Checking Safety Valve (G) under Maintenance.

6.Turn the regulator knob (D) out counterclockwise until fully closed. Ensure Regulated

Pressure Gauge (C) reads 0 psi.

7.Attach hose and accessories. NOTE: Always use a minimum 3/8" (9.5 mm) or greater air hose rated at 300 psi.

Risk of unsafe operation. Firmly grasp air hose in hand when installing or discon- necting to prevent hose whip.

Risk of unsafe operation. Do not use damaged or worn accessories.

Risk of Bursting. Too much air pressure causes a hazardous risk of bursting. Check the manufacturer’s maximum pressure rating for air tools and accessories. The regu- lator outlet pressure setting must never exceed the maximum pressure rating of the tool or accessory.

Operating Procedures

Start-up (Fig. 1)

1.Follow Pre-Start Checklist under Preparation for Use.

2.Move the On/Off switch (A) to the ON position and allow tank pressure to build. Motor will stop when tank pressure reaches cutout pressure.

Risk of Property Damage. Compressed air from the unit may contain wa­ter condensation and oil mist. Do not spray unfil­tered­ air at an item that could be damaged by moisture. Some air oper­ated­ tools or de­vices­ may require filtered air.

Read the instruc­tions­ for the air tool or device.

3. Adjust regulator (D) to desired setting. See Regulator under Features.

Shut-down (Fig. 1)

1.Move On/Off switch (A) to the OFF position. NOTE: If finished using compressor, follow Steps 2–6.

NOTE: When the unit has been turned off, it is normal to hear a short hiss of air being released.

NOTE: Unplug unit when not in use.

2.Turn the regulator knob (D) counterclockwise until fully closed. Ensure Regulated Pressure

Gauge (C) reads 0 psi. Push knob in to lock in place.

3.Remove hose and accessory.

Risk of unsafe operation. Firmly grasp air hose in hand when installing or disconnecting to prevent hose whip.

4.Drain the air tank, see Draining Air Tank under Maintenance. Ensure Air Tank Pressure

Gauge (B) reads 0 psi.

11

Image 11
Contents BTFP02028 Guide Dutilisation Manual DE InstruccionesWhat can happen Important Safety IntroductionDefinitions Safety Guidelines How to prevent itRisk to Breathing Asphyxiation How to prevent itAttachments & accessories What can happenRisk from Flying Objects Always wear certified safety equipmentTires Risk of Electrical ShockRisk of Unsafe Operation Can Happen How to prevent itRisk of Hot surfaces Risk from Moving PartsSpecifications Save These Instructions for Future USE Features FIG Fit the supplied wheels as shown in figures Installation Assembly AccessoriesDo not USE AN Adapter Installing HosesDisconnecting Hoses Grounding Instructions FigProduct.10 Extension CordsVoltage and Circuit Protection Compatibility LocationStart-up Fig Operating ProceduresPre-Start Checklist Fig Preparation For UseProcedure Daily Weekly See tank MaintenanceMaintenance Chart Checking Safety ValveChecking Air Filter Element Fig AccessoriesService Information Full One Year WarrantyGlossary Troubleshooting GuideProblem Code Can rupture or explode Troubleshooting Codes Code possible causeConserver ces directives Possible SolutionIntroduction Importante À LA Sécurité Définitions lignes directrices en matière de sécuritéCe qui peut se produire Comment l’Éviter Accessoires Risque d’Éclatement Ce qui peut se produire Comment l’Éviter Ce qui peut se produire Comment l’ÉviterRisque de choc Électrique Risque associÉ aux piÈces mobiles Son utilisationRisque associÉ au bruit Ce qui peut se produire Risque DE ChuteCE QUI Peut SE Produire Comment L’ÉVITER Hauteur Fiche techniqueModèle PoidsCaractÉristiques Composants FigDépasser la Risque DE RUPTURE. UneDair provoque un dangereux ’UTILISEZ PAS UN Adaptateur AssemblageDirectives relatives à la mise à la terre Fig Compatibilité EmplacementRallonges Protection de la tension et du circuitDémarrage Fig Mode d’emploiProcédures de fonctionnement Liste de vérification de pré-démarrage FigProcédure EntretienArrêt Fig Programme d’entretienVérification des éléments du filtre d’air Fig Vérification de la soupape de sûretéVidange du réservoir d’air Fig Garantie complète d’un 1 an AccessoiresInformation sur les réparations RéparationsProblème GlossaireGuide de dépannage Codes de dépannage Cause probableSolution Probable Fusible grillé, disjoncteur Possibilité d’un moteurPièces internes du moteur Vapeurs inflammablesRiesgo de explosión o incendio ¿Qué puede suceder? Instrucciones Importantes DE SeguridadDefiniciones Normas de seguridad Guarde estas instrucciones¿Qué puede suceder? Cómo evitarlo Riesgo de explosiónNeumáticos Modificaciones o intento de reparación del tanque de aireElementos y accesorios GravesRiesgo por piezas móviles Cómo evitarlo Riesgo de objetos despedidos ¿Qué puede suceder?Riesgo DE Caídas Riesgo por ruidos Cómo evitarlo EspecificacionesCaracterísticas Fig Componentes FigEn la presión del aire causa un peligroso riesgo Coloque las ruedas provistas como se muestra en la figura InstalaciónEnsamblaje Debe ensamblar el compresor antes de usarlo por primera vezLugar Cables prolongadoresVoltaje y protección del circuito CompatibilidadVoltaje y protección del circuito en la sección Instalación Preparación Para EL USOLista DE Control Previa a LA Puesta EN Marcha FIG Guarde el compresor en posición horizontal o verticalApagado FIG Procedimientos OperativosMantenimiento Puesta EN Marcha FIGDrenar EL Tanque DE Aire FIG Tabla DE MantenimientoProcedimiento Controlar LA Válvula DE Seguridad FIGReparaciones AccesorioInformación DEL Servicio Técnico Controlar EL Elemento DEL Filtro DE Aire FIGMEXICO, D.F Garantía completa de un añoCULIACAN, SIN GUADALAJARA, JALGlosario Código Causa posible CGuía de detección de problemaCódigos de detección de problemas CódigoDañado Grande para elRestringida Pérdidas de aire Ajuste las conexiones El regulador estáMarch