Schumacher SCI90 Moving and Storage Instructions, Specifications, Error Description Cause Code

Page 9

11.MOVING AND STORAGE INSTRUCTIONS

11.1Store the charger unplugged, in an upright position. The cord will still conduct electricity until it is unplugged from the outlet.

11.2If the charger is moved around the shop or transported to another location, take care to avoid/prevent damage to the cords, clips and charger. Failure to do so could result in personal injury or property damage.

12.SPECIFICATIONS

Input

230V~50Hz

.86A

 

 

 

– Slow

 

 

 

– Medium

1.15A

 

 

 

– Fast

2.85A

 

 

 

– Engine Start

8.5A

 

 

 

Output

 

 

 

 

 

– Slow

6/12V

 

 

3A

 

 

– Medium

6/12V

 

 

5A

 

 

– Fast

6/12V

 

 

20A 105 seconds on / 5A 180 seconds on

 

 

– Engine Start

12V

 

90A Peak 150A @ 0V

 

Weight

12.8 lbs. (5.82 kg)

Reverse Polarity Protection

Yes

 

 

 

13.TROUBLESHOOTING AND ERROR CODES Error Codes

ERROR

DESCRIPTION

CAUSE

CODE

 

 

 

The battery voltage is still under

Could be caused by trying to charge a 6 volt

F01

10V (for a 12V battery) or 5V

battery on the 12 volt setting, or the battery

(for a 6V battery) after 2 hours of

could be bad; have it checked or replaced.

 

 

charging.

 

F02

The charger cannot desulfate

The battery could not be desulfated; have it

the battery.

checked or replaced.

 

 

The battery was unable to reach

Could be caused by trying to charge a large

 

the “full charged” voltage.

battery or bank of batteries on too low of a

F03

 

current setting, or the battery may have a

 

shorted cell. Try again with a higher current

 

 

 

 

setting, or have the battery checked or

 

 

replaced.

F04

The connections to the battery

The battery is connected backwards. Unplug

are reversed.

the charger and reverse the connections to

 

 

the battery.

 

The charger was unable to

The battery won’t hold a charge. Could be

 

keep the battery fully charged in

caused by a drain on the battery, or the

F05

maintain mode.

battery could be bad. Make sure there are

 

no loads on the battery. If there are, remove

 

 

 

 

them. If there are none, have the battery

 

 

checked or replaced.

 

The charger detected that the

The charger automatically shuts the current

F06

battery may be getting too hot

off if it detects the battery may be getting too

(thermal runaway).

hot or the battery may have a shorted cell.

 

 

 

Have the battery checked or replaced.

If you get an error code, check the connections and settings and/or replace the battery.

9

Image 9
Contents SCI90 Model SCI90 Important Safety Instructions Save These InstructionsPersonal Precautions Follow These Steps When Battery is Installed in Vehicle Follow These Steps When Battery is Outside VehicleCharger Location Battery Type/Mode Button Grounding and AC Power Cord ConnectionsControl Panel Charge Rate ButtonOperating Instructions Maintain Mode Desulfation ModeMaintaining a Battery 3A Charge Rate Using the Engine Start featureUsing the Alternator Performance Tester Using the Battery Voltage TesterMaintenance Instructions Engine Starting NotesTroubleshooting and Error Codes Error Codes SpecificationsError Description Cause Code Moving and Storage InstructionsProblem Possible Cause Solution TroubleshootingConnected ChargingPage Declaration of Conformity Achtung STROMSCHLAG- Oder Brandgefahr Wichtige Sicherheitshinweise Diese Anleitung AufbewahrenAchtung Gefahr Explosiver Gase Page Page Bedienfeld LadegeschwindigkeitstasteBatterietyp-/Modustaste Bedienungsanleitung DigitalanzeigeBatteriedaten AufladenLadevorgang abgebrochen Automatischer LademodusDesulfatierungsmodus Abschluss des LadevorgangsVerwenden der Motorstart-Funktion Hinweise zum MotorstartVerwenden des Batteriespannungsprüfers Verwenden des Lichtmaschinen-Spannungsprüfers WartungsanleitungTransport UND Lagerung Technische Daten Fehlersuche UND Fehlercodes FehlercodesFehlercode Beschreibung Ursache Problem Mögliche Ursache Abhilfe FehlersucheAngeschlossen Hoopeston, USA -800-621-5485 services@schumacherelectric.com Konformitätserklärung Advertencia Riesgo DE Descarga Eléctrica O Fuego Modelo SCI90Advertencia Riesgo DE Gases Explosivos Page Botón para seleccionar capacidad de carga Pantalla digital Tipo de batería / Botón seleccionar Modo de cargaInstrucciones DE Funcionamiento Información de bateríaIndicador de conexión de batería Defectos del arranqueModo automático de carga Carga interrumpidaDE Arranque DEL Motor Utilizar la función de encendido de motorNotas sobre el arranque del motor Utilizar el probador de tensión de bateríaInstrucciones DE Mantenimiento Utilización de un probador de rendimiento del alternadorInstrucciones DE Almacenamiento Y Movimiento EspecificacionesCódigo Descripción RAZÓN/SOLUCIÓN Error Localización y Solución de ProblemasLA LUZ LED Carga Completa Declaración DE Conformidad Avertissement Risque DE Choc Électrique OU D’INCENDIE Consignes DE Sécurité Importantes Conserver CES ConsignesAvertissement Risque DE GAZ Explosifs Page Bouton Taux de charge Panneau DE ContrôleAffichage numérique Type de batterie / Bouton ModeConsignes D’UTILISATION Informations sur la batterieMode de désulfatation Mode de chargement automatiqueMode Entretien Indicateur de connexion de la batterieUtilisation du testeur de tension de batterie Consignes D’ENTRETIEN Tester la performance de l’alternateurInstructions DE Transport ET Stockage CaractéristiquesDepannage ET Codes D’ERREUR Codes d’erreur Code Description Raison / Solution ’ERREURDépannage LED ConnectéeCharge Complète Déclaration DE Conformité