11.MOVING AND STORAGE INSTRUCTIONS
11.1Store the charger unplugged, in an upright position. The cord will still conduct electricity until it is unplugged from the outlet.
11.2If the charger is moved around the shop or transported to another location, take care to avoid/prevent damage to the cords, clips and charger. Failure to do so could result in personal injury or property damage.
12.SPECIFICATIONS
Input | 230V~50Hz | ||||
.86A |
|
|
| ||
– Slow |
|
|
| ||
– Medium | 1.15A |
|
|
| |
– Fast | 2.85A |
|
|
| |
– Engine Start | 8.5A |
|
|
| |
Output |
|
|
|
|
|
– Slow | 6/12V |
|
| 3A | |
|
| ||||
– Medium | 6/12V |
|
| 5A | |
|
| ||||
– Fast | 6/12V |
|
| 20A 105 seconds on / 5A 180 seconds on | |
|
| ||||
– Engine Start | 12V |
| 90A Peak 150A @ 0V | ||
| |||||
Weight | 12.8 lbs. (5.82 kg) | ||||
Reverse Polarity Protection | Yes |
|
|
|
13.TROUBLESHOOTING AND ERROR CODES Error Codes
ERROR | DESCRIPTION | CAUSE | |
CODE | |||
|
| ||
| The battery voltage is still under | Could be caused by trying to charge a 6 volt | |
F01 | 10V (for a 12V battery) or 5V | battery on the 12 volt setting, or the battery | |
(for a 6V battery) after 2 hours of | could be bad; have it checked or replaced. | ||
| |||
| charging. |
| |
F02 | The charger cannot desulfate | The battery could not be desulfated; have it | |
the battery. | checked or replaced. | ||
| |||
| The battery was unable to reach | Could be caused by trying to charge a large | |
| the “full charged” voltage. | battery or bank of batteries on too low of a | |
F03 |
| current setting, or the battery may have a | |
| shorted cell. Try again with a higher current | ||
|
| ||
|
| setting, or have the battery checked or | |
|
| replaced. | |
F04 | The connections to the battery | The battery is connected backwards. Unplug | |
are reversed. | the charger and reverse the connections to | ||
|
| the battery. | |
| The charger was unable to | The battery won’t hold a charge. Could be | |
| keep the battery fully charged in | caused by a drain on the battery, or the | |
F05 | maintain mode. | battery could be bad. Make sure there are | |
| no loads on the battery. If there are, remove | ||
|
| ||
|
| them. If there are none, have the battery | |
|
| checked or replaced. | |
| The charger detected that the | The charger automatically shuts the current | |
F06 | battery may be getting too hot | off if it detects the battery may be getting too | |
(thermal runaway). | hot or the battery may have a shorted cell. | ||
| |||
|
| Have the battery checked or replaced. |
If you get an error code, check the connections and settings and/or replace the battery.
• 9 •