Genie 4042 Sectional Door, One-Piece Door, 3’ - 4’, Safe-T-Beam STB SYSTEM CHECK, 1 Door balance

Page 18
Safe-T-Beam® (STB) SYSTEM CHECK

–CONTACT A TRAINED DOOR SYSTEM TECHNICIAN. WARNING

Garage door hardware (springs, cables, brackets, pulleys, etc.) are under extreme pressure and tension.

DO NOT attempt to repair or adjust door

springs or any hardware, and DO NOT OPERATE garage door automatically or manually if door is improperly balanced or springs are broken.

ROUTINE MONTHLY MAINTENANCE WARNING

Use wall console supplied with opener. Other approved wall consoles may be available. Unapproved or incompatible wall consoles can cause the opener to operate unexpectedly.

Safe-T-Beam® (STB) SYSTEM CHECK

• STB Red and Green LEDs ON steady, system OK

CONTACT A TRAINED DOOR SYSTEM TECHNICIAN.

ROUTINE MONTHLY MAINTENANCE

Basic monthly maintenance tasks.

Safe-T-Beam® System Check

Door balance

Contact reverse

Instructions for these tasks and others are found on

STB Red LED flashes

Check for obstruction

Check alignment

Verify wire routing from STBs to STB connection in powerhead

Check for signal interference from another Safe-T-Beam® unit

FROM STBs

STB

FROM WALL

CONSOLE

•Safe-T-Beam® System CheckNOTDOOR BALANCE (SPRING TENSION)NOT

USED USED

BWC IWC

the following pages.

DOOR BALANCE (SPRING TENSION)

No STB Red or Green LED displayed

Check wiring and wire connections

With the door closed, pull 3’ - 4’ release handle DOWN and let go to release door carriage assembly from drive system.

Raise door manually approximately 3’- 4’ and release.

Door should remain stationary or move very slightly.

If door moves quickly, CONTACT A TRAINED DOOR SYSTEM TECHNICIAN.

Close the door.

Verify RED block in carriage is in the up position. (refer to page 19)

Operate door using remote or wall console.

Door will re-attach itself to carriage assembly.

3’ - 4’

Sectional Door

FIG. 6-1 Door balance

3’ - 4’

One-Piece Door

CONTACT REVERSE TEST (Monthly test)

The Force and Limit settings MUST be COMPLETED before testing. (See pages 6-7)

1.Test.

Open garage door using wall console.

Place a 2" x 4" board (laid flat) under center of garage door opening (Fig. 6-2).

Close garage door using wall console.

When door contacts board, the door must

stop (within 2 seconds) and reverse direction returning to open position.

2.Adjustment.

If the door:

Stops before it contacts the 2 x 4 board, it may simply be responding to an improperly set down limit. Return to pages 6-7 and repeat steps 1 through 10 to correct down limit.

Stops after contacting the 2 x 4 board and does not reverse, it may need an adjustment to the down limit. Return to pages 6-7 and repeat steps 1 through 10 to correct down limit.

Test again. Repeat as necessary until door

reverses upon contacting board.

FIG. 6-2 2 x 4 under center of door opening

18

©2011 The Genie Company

3/2011

Image 18
Contents GARAGE DOOR OPENER SILENTMAX1.800.354.3643 Homelink and Car2U compatiblePotential Hazard SAFETY INFORMATIONCONVENTIONS USED IN THESE INSTRUCTIONS PreventionSAFETY FEATURES OPENER FEATURESINTELLICODE 2 Access Security System Wall Console, SeriesPage InstallationReference TABLE OF CONTENTSand installation has been completed IMPORTANT INSTALLATION INSTRUCTIONSBegin here after the openers physical assembly Begin programming by setting Limits see next pagePROGRAM 1 PROGRAMMING LIMITS & FORCEA CLOSE DOOR TRAVEL LIMIT NOTE If bullet has NOT been engaged toB OPEN DOOR TRAVEL LIMIT CONTACT REVERSE TEST 2 PROGRAM INTELLICODE 2 REMOTE TO POWERHEAD RELEASEHomelink programming IntelliCode 1 remote or wireless keypad programmingGenie IntelliCode 1 wireless keypad Homelink or Car2U programmingPower Cord REFERENCE - POWERHEAD & RAIL ASSEMBLED VIEWRÉFÉRENCE - VUE DE LA TÊTE D’ALIMENTATION & DU RAIL ASSEMBLÉ Rail ConnectorTYPICAL SUPPORT BRACKET NOT PROVIDED POWER CORD* TO GROUNDED OUTLETINSTALACIÓN HABITUAL DE UNA PUERTA SECCIONAL EXTENSION SPRINGADVERTENCIA TYPICAL ONE PIECE DOOR INSTALLATIONAVERTISSEMENT POWER CORD* TO 120V GROUNDED OUTLETProgramming Overview 4 OVERVIEW OF POWERHEAD CONTROLSon powerhead ButtonsFIG. 5-1 Remote 5 OVERVIEW - REMOTES AND OPTIONSand hold PURPLEUse this INTELLICODE FEATURESRed = IntelliCode 1 / Green = IntelliCode If you have8. SAVE THESE INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS6 MAINTENANCE & TROUBLESHOOTING TRANSMITTER COMPLIANCE STATEMENTSectional Door ROUTINE MONTHLY MAINTENANCE2. Adjustment One-Piece DoorRESET - OPEN/CLOSE TRAVEL LIMIT 1. Disconnect power to door opener2. Reconnect power to door opener DOORWALL CONSOLE - OVERVIEW Indicator Lightwire routing Open/Close ButtonCHAIN OR BELT - TENSION ADJUSTMENT REMOTE BATTERY REPLACEMENTObserve all safety warning and precautions Powerhead LEDs Round LED Long LED ADJUSTMENT GUIDE - SPEED SETTINGSCHANGE SPEED SETTING Speed LevelADJUSTMENT GUIDE - FORCE SETTINGS CHANGE FORCE SETTINGForce Level TROUBLESHOOTING GUIDE - OPERATION Possible Problem TROUBLESHOOTING GUIDE - POWERHEAD LEDsPowerhead LED SolutionAVERTISSEMENT REFERENCE - CIRCUIT WIRING DIAGRAMPOWER CORD ELECTRICAL SHOCKSILENTMAX LIMITED WARRANTY This page left blank This page left blank This page left blank Console murale de série Commande Automatique ForceGuardCARACTÉRISTIQUES DU PORTIER ÉLECTRIQUE CARACTÉRISTIQUES DE SÉCURITÉ5 Vue densemble des télécommandes et des options TABLE DES MATIÈRESRéférence Facultatif - installation duelle de console de murUne fois lopener lassemblée physique et IMPORTANTES INSTRUCTIONS D’INSTALLATIONlinstallation de s a été accomplie commencent ici voir la page suivanteRÉGLER & VÉRIFIER LES LIMITES ET LA FORCE 1 PROGRAMMATION DES LIMITES ET DE LA FORCEA LIMITE DE COURSE DE FERMETURE DE PORTE PROGRAM SETB OUVRIR LA LIMITE DU TRAJET GRAMLE TEST D’INVERSION AU CONTACT La programmation de base du moteur est terminée Le portier électrique est prêt à lusageProgrammation Homelinkou Car2U Programmation de la télécommande ou du clavier sans fil IntelliCodeProgrammation Homelink Genie IntelliCodeVue d’ensemble de la programmation 4 VUE DENSEMBLE DES COMMANDES DE LA TÊTE D’ALIMENTATIONFIG. 4-2 Boutons de commande BoutonsFIG. 5-1 Télécommandes 5 VUE DENSEMBLE - EXTÉRIEURS ET OPTIONSCERTIFIÉ PAR LA FCC ET IC LES CARACTÉRISTIQUES D’INTELLICODE LED rouge8. CONSERVER CES INSTRUCTIONS IMPORTANTES CONSIGNES DE SÉCURITÉ6 ENTRETIEN ET DÉPANNAGE Porte en sectionFIG. 6-2 2 x 4 sous le centre de louverture de la porte CHANGER LES AMPOULESVERROUILLAGE DU CHARIOT PORTENest pas disponible sur tous les modèles FIG. 6-3 Désactiver du chariotIndicator Light FACULTATIF - INSTALLATION DUELLE DE CONSOLE DE MURLA CONSOLE DU MUR - VUE DENSEMBLE Bouton pour OUVRIR/FERMERObservez tous les avertissement et précautions de sûreté REMPLACEMENT DE LA PILECHAÎNE OU AJUSTEMENT DE TENSION DE COURROIE Démontez la puissance de louvreur avant de commencer cette tâcheNiveau de vitesse CHANGEMENT DU RÉGLAGE DE VITESSENiveau de force GUIDE D’AJUSTEMENT- RÉGLER LA FORCECHANGEMENT DU RÉGLAGE DE LA FORCE DEL de la tête d’alimentationLa télécommande GUIDE DE DÉPANNAGE - FONCTIONNEMENTtélécommande PROBLÈMELa porte ne fonctionne GUIDE DE DÉPANNAGE - LES DEL DE LA TÊTE D’ALIMENTATIONProblème possible que lorsque ferméeP DE UCIÓN SO DE GUÍAR OBLEMASO FUNCIONAMIEN - OBLEMAS P DE UCIÓN SO DE GUÍAR Tada er a turfunciona te completameza fue de el Ni ga la LEDedonda LED o tri eléc cabezal del LEDelocidad de el Ni OCIDAD VEDE ACIÓN ONFIGU tarea BANDA O CADENA DE TENSIÓN DE AJUSTEINSTALACIÓN ATENCIÓNindependiente DOBLE, PARED DE OPCIONAL CONSOLA4-6 .FIG PUERTAPUERTA carro del LiberaciónTENCIA VE RAD ta pue la de2-6 FIG mensual Prueba OARDE IMPORTANTES SEGURIDAD DE INSTRUCCIONESCIONES INSTRU AS OBLEMASATENCIÓN segundos OPCIONES Y REMOTOS CONTROLES - GENERAL DESCRIPCIÓNRemoto Control púrpuraLED de es Colo ma ProgrBotones y Displ LEDControl remoto IntelliCode Programación de HomelinkHomelinkCar2Uo la unidad damotorizpúrpura que el LEDPROGRAM La programación básica de la unidad motorizada está completaLIBERE VEA el LEDProgramación de los controles remotos en la página siguiente PRUEBA DE REVERSA DE CONTACTOOBSERVE el LED azul intermitente largo B LÍMITE DE RECORRIDO DEL ABRE PUERTASESTABLECER LA FUERZA La fuerza se En la consola de paredRECORRIDO PROGRAMACIÓN DE LÍMITES Y FUERZAA LÍMITE CERRAR LA PUERTAy física asamblea la a terminado han opener el ez aquí omienzans de instalación la siguiente página la consulteSección ÍNDICEInstalación encia e rReada teg i tor vimien m den Detección verseIII erie S automática iluminación de SistemaP DANGERS DES SOMMAIRE SEGURIDAD DE CIÓN INFORMSÉCURITÉ A À ATIVES RE TIONSL INFORML ANTES IMPOR SÛRETÉ DE INSTRUCTIONSMANUAL ESTE GUARDE 200 1SILENTMAX3643.354.800.1 GARAJE DE TAS PUE DE /OPERADOR GE GAR DE TE PO-OUVREA