Genie 4042 manual Troubleshooting Guide - Operation

Page 24
TROUBLESHOOTING GUIDE - OPERATION

TROUBLESHOOTING GUIDE - OPERATION

FOR HELP-1-800-35-GENIE OR WWW.GENIECOMPANY.COM

 

 

 

 

PROBLEM

 

WHAT TO DO

 

 

 

 

 

Check power source,

 

 

 

– Plug a lamp into outlet used for powerhead. If lamp works, power source is OK.

 

 

– If not, check fuse or circuit breaker.

 

Opener does NOT run

• If power is OK,

 

 

– Check connections at powerhead terminals and at wall console.

from wall console.

 

 

– Limits must be set with door arm connected to door.

 

 

 

Check if wall console Sure-Lock™ is ON. Turn Sure-Lock™ OFF & check operation.

 

• Check for reversed, broken, or cut wires. Staples can cut insulation and short wires.

 

 

Repair or replace.

 

 

• Make sure carriage is engaged to belt bullet. See pages 11 and 19. Refer to

Opener runs, but door

 

Installation poster or download poster from WWW.GENIECOMPANY.COM.

 

– Ensure carriage is in engaged position. See page 19.

does NOT move.

 

Check to make sure belt is not broken or OFF its pulley.

 

 

• Check FORCE ADJUSTMENT. See page 23.

 

Opener works from

Check all remotes.

 

wall console, but NOT

• Replace remote battery with good one. See page 21.

from remote.

• Program remote to powerhead. See pages 9 or 10.

Relocate remote inside car and or point remote at garage door. Remote has less than • Replace battery. See page 21.

25 feet operating

• Reposition door opener antenna.

range or no operation.

• Remote LED does not come ON with button push - replace battery. See page 21.

 

• Eliminate possible competing signals (satellite radio, FiOS® TV).

Door starts down,

• If a NEW installation, check Door Arm position. Refer to Installation poster or download

poster from WWW.GENIECOMPANY.COM.

then STOPS and goes

• Check if Limits are properly set. See pages 6-7.

back up.

• Check if Safe-T-Beam® Red LED is flashing. See page 18.

OR

• Check Safe-T-Beam® system for beam obstruction or misalignment of lenses. See page 18.

• Check garage door for binding.

If an operational problem exists, and opener will not close. The opener can be forced to

Safe-T-Beam® System close as follows; Press and hold the wall console button until door is completely closed.

malfunction.• Check for interference from adjacent Safe-T-Beam® units.

Contact The Genie Company at 1-800-35-GENIE.

Door starts down,

Check Safe-T-Beam® wire connections at powerhead. See page 18.

then STOPS before it

Check Limits are properly set. See pages 6-7.

is closed.

• Check CONTACT REVERSE. See page 18.

OR

Check garage door for binding.

Door will only open.

Check closing "FORCE" adjustment. See page 23.

Door starts up, but

• Check Limits are properly set. See pages 6-7.

Be sure door, opener, and springs are in good repair, properly lubricated and balanced.

STOPS before it is

Check opening "FORCE" adjustment. See page 23.

completely open.

WARNING: If you suspect a problem with the garage door hardware or springs,

 

 

contact The Genie Company at 1-800-35-GENIE.

 

• Check Limits are properly set. See pages 6-7.

Door will only run

• Check Sure-Lock™. Sure-Lock™ should be OFF for normal operation. See page 20.

Check door balance, condition, and door spring.

closed.

Check opening "FORCE" adjustment. See page 23.

 

WARNING: If you suspect a problem with the garage door hardware or springs,

 

 

contact The Genie Company at 1-800-35-GENIE.

Door opener starts for

Button stuck on wall console or remote.

• Was a remote lost or stolen? Erase all remotes from powerhead memory and program

no reason.

 

new remotes. See page 15.

 

 

24

©2011 The Genie Company

3/2011

Image 24
Contents SILENTMAX 1.800.354.3643GARAGE DOOR OPENER Homelink and Car2U compatibleSAFETY INFORMATION CONVENTIONS USED IN THESE INSTRUCTIONSPotential Hazard PreventionOPENER FEATURES INTELLICODE 2 Access Security SystemSAFETY FEATURES Wall Console, SeriesInstallation ReferencePage TABLE OF CONTENTSIMPORTANT INSTALLATION INSTRUCTIONS Begin here after the openers physical assemblyand installation has been completed Begin programming by setting Limits see next page1 PROGRAMMING LIMITS & FORCE A CLOSE DOOR TRAVEL LIMITPROGRAM NOTE If bullet has NOT been engaged toB OPEN DOOR TRAVEL LIMIT CONTACT REVERSE TEST 2 PROGRAM INTELLICODE 2 REMOTE TO POWERHEAD RELEASEIntelliCode 1 remote or wireless keypad programming Genie IntelliCode 1 wireless keypadHomelink programming Homelink or Car2U programmingREFERENCE - POWERHEAD & RAIL ASSEMBLED VIEW RÉFÉRENCE - VUE DE LA TÊTE D’ALIMENTATION & DU RAIL ASSEMBLÉPower Cord Rail ConnectorPOWER CORD* TO GROUNDED OUTLET INSTALACIÓN HABITUAL DE UNA PUERTA SECCIONALTYPICAL SUPPORT BRACKET NOT PROVIDED EXTENSION SPRINGTYPICAL ONE PIECE DOOR INSTALLATION AVERTISSEMENTADVERTENCIA POWER CORD* TO 120V GROUNDED OUTLET4 OVERVIEW OF POWERHEAD CONTROLS on powerheadProgramming Overview Buttons5 OVERVIEW - REMOTES AND OPTIONS and holdFIG. 5-1 Remote PURPLEINTELLICODE FEATURES Red = IntelliCode 1 / Green = IntelliCodeUse this If you haveIMPORTANT SAFETY INSTRUCTIONS 6 MAINTENANCE & TROUBLESHOOTING8. SAVE THESE INSTRUCTIONS TRANSMITTER COMPLIANCE STATEMENTROUTINE MONTHLY MAINTENANCE 2. AdjustmentSectional Door One-Piece Door1. Disconnect power to door opener 2. Reconnect power to door openerRESET - OPEN/CLOSE TRAVEL LIMIT DOORIndicator Light wire routingWALL CONSOLE - OVERVIEW Open/Close ButtonCHAIN OR BELT - TENSION ADJUSTMENT REMOTE BATTERY REPLACEMENTObserve all safety warning and precautions ADJUSTMENT GUIDE - SPEED SETTINGS CHANGE SPEED SETTINGPowerhead LEDs Round LED Long LED Speed LevelADJUSTMENT GUIDE - FORCE SETTINGS CHANGE FORCE SETTINGForce Level TROUBLESHOOTING GUIDE - OPERATION TROUBLESHOOTING GUIDE - POWERHEAD LEDs Powerhead LEDPossible Problem SolutionREFERENCE - CIRCUIT WIRING DIAGRAM POWER CORDAVERTISSEMENT ELECTRICAL SHOCKSILENTMAX LIMITED WARRANTY This page left blank This page left blank This page left blank Commande Automatique ForceGuard CARACTÉRISTIQUES DU PORTIER ÉLECTRIQUEConsole murale de série CARACTÉRISTIQUES DE SÉCURITÉTABLE DES MATIÈRES Référence5 Vue densemble des télécommandes et des options Facultatif - installation duelle de console de murIMPORTANTES INSTRUCTIONS D’INSTALLATION linstallation de s a été accomplie commencent iciUne fois lopener lassemblée physique et voir la page suivante1 PROGRAMMATION DES LIMITES ET DE LA FORCE A LIMITE DE COURSE DE FERMETURE DE PORTERÉGLER & VÉRIFIER LES LIMITES ET LA FORCE PROGRAM SETB OUVRIR LA LIMITE DU TRAJET GRAMLE TEST D’INVERSION AU CONTACT La programmation de base du moteur est terminée Le portier électrique est prêt à lusageProgrammation de la télécommande ou du clavier sans fil IntelliCode Programmation HomelinkProgrammation Homelinkou Car2U Genie IntelliCode4 VUE DENSEMBLE DES COMMANDES DE LA TÊTE D’ALIMENTATION FIG. 4-2 Boutons de commandeVue d’ensemble de la programmation BoutonsFIG. 5-1 Télécommandes 5 VUE DENSEMBLE - EXTÉRIEURS ET OPTIONSCERTIFIÉ PAR LA FCC ET IC LES CARACTÉRISTIQUES D’INTELLICODE LED rougeIMPORTANTES CONSIGNES DE SÉCURITÉ 6 ENTRETIEN ET DÉPANNAGE8. CONSERVER CES INSTRUCTIONS Porte en sectionFIG. 6-2 2 x 4 sous le centre de louverture de la porte CHANGER LES AMPOULESPORTE Nest pas disponible sur tous les modèlesVERROUILLAGE DU CHARIOT FIG. 6-3 Désactiver du chariotFACULTATIF - INSTALLATION DUELLE DE CONSOLE DE MUR LA CONSOLE DU MUR - VUE DENSEMBLEIndicator Light Bouton pour OUVRIR/FERMERREMPLACEMENT DE LA PILE CHAÎNE OU AJUSTEMENT DE TENSION DE COURROIEObservez tous les avertissement et précautions de sûreté Démontez la puissance de louvreur avant de commencer cette tâcheNiveau de vitesse CHANGEMENT DU RÉGLAGE DE VITESSEGUIDE D’AJUSTEMENT- RÉGLER LA FORCE CHANGEMENT DU RÉGLAGE DE LA FORCENiveau de force DEL de la tête d’alimentationGUIDE DE DÉPANNAGE - FONCTIONNEMENT télécommandeLa télécommande PROBLÈMEGUIDE DE DÉPANNAGE - LES DEL DE LA TÊTE D’ALIMENTATION Problème possibleLa porte ne fonctionne que lorsque ferméeOBLEMAS O FUNCIONAMIEN - OBLEMASP DE UCIÓN SO DE GUÍAR P DE UCIÓN SO DE GUÍAR Ta tu rfuncionaada er te completamega la LED edonda LEDza fue de el Ni o tri eléc cabezal del LEDelocidad de el Ni OCIDAD VEDE ACIÓN ONFIGU tarea BANDA O CADENA DE TENSIÓN DE AJUSTEATENCIÓN independienteINSTALACIÓN DOBLE, PARED DE OPCIONAL CONSOLAPUERTA PUERTA4-6 .FIG carro del Liberaciónta pue la de 2-6 FIGTENCIA VE RAD mensual Prueba OIMPORTANTES SEGURIDAD DE INSTRUCCIONES CIONES INSTRU ASARDE OBLEMASATENCIÓN OPCIONES Y REMOTOS CONTROLES - GENERAL DESCRIPCIÓN Remoto Controlsegundos púrpurama Progr BotonesLED de es Colo y Displ LEDProgramación de Homelink HomelinkCar2UoControl remoto IntelliCode la unidad damotorizpúrpura que el LEDLa programación básica de la unidad motorizada está completa LIBEREPROGRAM VEA el LEDProgramación de los controles remotos en la página siguiente PRUEBA DE REVERSA DE CONTACTOB LÍMITE DE RECORRIDO DEL ABRE PUERTAS ESTABLECER LA FUERZA La fuerza seOBSERVE el LED azul intermitente largo En la consola de paredPROGRAMACIÓN DE LÍMITES Y FUERZA A LÍMITERECORRIDO CERRAR LA PUERTAaquí omienzan s de instalación lay física asamblea la a terminado han opener el ez siguiente página la consulteÍNDICE InstalaciónSección encia e rReverse III erie Sada teg i tor vimien m den Detección automática iluminación de SistemaSEGURIDAD DE CIÓN INFORM SÉCURITÉ A À ATIVES RE TIONSL INFORMLP DANGERS DES SOMMAIRE ANTES IMPOR SÛRETÉ DE INSTRUCTIONS200 1SILENTMAX 3643.354.800.1MANUAL ESTE GUARDE GARAJE DE TAS PUE DE /OPERADOR GE GAR DE TE PO-OUVREA