TROUBLESHOOTING GUIDE - OPERATION (CONTINUED)..................................................................... FOR | ||||
|
|
|
| |
PROBLEM |
|
| WHAT TO DO | |
|
|
| ||
Noisy operation. | • Be sure all door fasteners are tight. |
| ||
• | Be sure garage door is in good repair, properly lubricated and balanced. | |||
| • | Be sure opener is in good repair. |
| |
| • | Check operating condition of door. See pages 18. Door may need professional repair/ | ||
|
| adjustment. |
| |
Door opener runs | • | Is this opener installed on a one piece door? Normal speed for one piece door is | ||
| lowest speed setting. |
| ||
slow. |
|
| ||
• If carriage travel is less than 6 feet, opener configures programming for a one piece | ||||
| ||||
|
| door. |
| |
| • | Check door speed. See page 22. |
|
TROUBLESHOOTING GUIDE - POWERHEAD LEDs | FOR | |||
|
|
|
| |
Powerhead LED | Possible Problem | Solution | ||
|
| |||
Round LED | Long LED | |||
|
| |||
|
|
|
| |
|
| Normal operation | None required | |
OFF | OFF |
| Check power supply | |
No response from unit | Contact a trained door system | |||
|
| |||
|
|
| technician | |
ON/RED/ | ON/RED/ | Limits NOT set properly | Reprogram Limits, see pages | |
STEADY | STEADY | |||
|
| |||
ON/RED/ | ON/RED/ | Program error | Unplug unit, wait 5 seconds, plug in | |
| Contact a trained door system | |||
FLASHING | FLASHING | Component failure | ||
technician | ||||
|
|
| ||
ON/BLUE/ | OFF | Remote NOT programmed | Program remote, see page 9 | |
FLASHING | ||||
|
|
| ||
|
|
| Program remote using IntelliCode® | |
ON/PURPLE/ | OFF | IntelliCode® 1 remote NOT | 2 remote, see page 9, then program | |
FLASHING | programmed | IntelliCode® 1 remote using | ||
| ||||
|
|
| instructions on page 10 | |
|
| Remove obstruction, recheck unit | ||
ON/RED/ |
| obstruction | ||
OFF |
| |||
FLASHING | Check alignment of | |||
| ||||
|
| interference | and nearest other | |
|
| Door contact in up or down | Remove obstruction | |
| ON/RED/ | travel | ||
OFF |
| |||
FLASHING | Door component failure | Check door spring, track, rollers, hinges | ||
| ||||
|
| detected | and fixtures | |
OFF | ON/RED/ | Thermal cutout | DO NOT unplug unit | |
STEADY | Wait until LED clears before operating | |||
|
|
©2011 The Genie Company | 3/2011 | 25 |