Genie 4042 manual Wall Console - Overview, Indicator Light, Open/Close Button, Sure-Lock Button

Page 20
WALL CONSOLE - OVERVIEW

This opener has a Serial Number sticker in which the serial numbers begin with 10 or higher.

ATTENTION

If your garage door opener has a Serial Number sticker which looks like this, in which the first two numbers are 10 or higher, your opener will operate using this Series III wall control.

MODEL AC SR3

THE GENIE COMPANY

FCC ID: B8Q AC SR3

Residential Door Operator

IC: 2133A-CSD1D

120V. 60HZ. 5A

S/N:10XXXX XXXXXXX

 

FOR HE P C L 1 800 35GENIE OR WWW GEN ECOMPANY COM

Follow the instructions on this page.

Wall consoles from other manufacturers may not work with openers of these serial number groups. Genie® Series I wall buttons and Series II wall consoles will not work with openers of this serial number group.

WALL CONSOLE - OVERVIEW

Use only the Series III wall console provided with this unit.

Wall console has three buttons and one indicator light.

Indicator Light

Indicator light will display Red when wall console is properly wired and Sure-Lock™ is OFF. When Sure- Lock™ is ON indicator light flashes.

Open/Close Button

Use this button to open or close garage door. When Sure-Lock™ is ON the Open/Close button will CLOSE door only. Note: Constant button pressure in the CLOSE mode will override error responses in the powerhead and close door.

Open/Close Button

Open and closes door from inside garage

Sure-Lock™ Button

LOCK disables controls after door is completely closed

UNLOCK allows controls to

work normally

Indicator Light

Red indicator light is always ON

When Sure-Lock™ is ON the indicator light flashes

Independent Light Control Button

Controls door opener lights from inside garage

Tip: If indicator light on wall console comes ON, but

 

there is NO

FROM STBs

FROM STBs

 

operation from

 

 

 

 

 

 

 

FROM WALL

 

FROM WALL

 

buttons - verify

 

 

 

 

 

 

 

CONSOLE

 

CONSOLE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

wall console

 

 

 

 

 

 

 

 

 

 

 

 

 

 

wire routing

 

 

 

 

 

 

 

 

 

 

 

 

NOT

NOT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

at powerhead

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

USED

USED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

connector.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

STB

 

BWC

 

IWC

 

STB BWC IWC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Independent Light Control Button

Use this button to turn powerhead lights ON. Powerhead lighting will remain ON until this button is pressed again or a door action has been completed. Note: If opener has a Motion Detector sensor the sensor will keep powerhead lights ON as long as motion is detected.

Sure-Lock™ Button

When Sure-Lock™ is ON the powerhead cannot be activated by the wall console or a remote.

Press and hold for 5 seconds (or until Indicator Light flashes) to activate Sure-Lock™.

Press and release to turn Sure-Lock™ OFF.

OPTIONAL DUAL WALL CONSOLE - INSTALLATION

Use only a Series III wall console when adding a second wall console. The optional second Genie® Series III wall console must be purchased separately.

TO

TO WALL CONSOLE #1

POWERHEAD

 

FROM STBs

FROM WALL

CONSOLE

NOT

B/W

W

B/W

W

NOT

 

 

USED

USED

 

 

 

STB

 

BWC

 

IWC

WALL

WALL

Wire connector

CONSOLE #1

CONSOLE #2

on Powerhead

 

 

 

 

 

 

 

 

 

OR

 

 

 

 

 

 

 

 

BOTH TO POWERHEAD

FROM STBs

FROM WALL

 

 

 

 

 

CONSOLE #1

 

 

 

 

 

 

 

FROM WALL

 

 

 

 

 

 

CONSOLE #2

 

 

 

 

 

 

 

NOT

NOT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

USED

USED

 

 

 

 

 

 

 

 

 

B/W W

B/W

W

 

 

 

 

 

 

 

 

STB

 

BWC

 

IWC

 

 

 

 

 

 

 

 

Wire connector on

 

 

 

Powerhead

 

WALL

WALL

 

 

 

 

 

 

CONSOLE #1

CONSOLE #2

20

©2011 The Genie Company

3/2011

Image 20
Contents SILENTMAX 1.800.354.3643GARAGE DOOR OPENER Homelink and Car2U compatibleSAFETY INFORMATION CONVENTIONS USED IN THESE INSTRUCTIONSPotential Hazard PreventionOPENER FEATURES INTELLICODE 2 Access Security SystemSAFETY FEATURES Wall Console, SeriesInstallation ReferencePage TABLE OF CONTENTSIMPORTANT INSTALLATION INSTRUCTIONS Begin here after the openers physical assemblyand installation has been completed Begin programming by setting Limits see next page1 PROGRAMMING LIMITS & FORCE A CLOSE DOOR TRAVEL LIMITPROGRAM NOTE If bullet has NOT been engaged toB OPEN DOOR TRAVEL LIMIT CONTACT REVERSE TEST 2 PROGRAM INTELLICODE 2 REMOTE TO POWERHEAD RELEASEIntelliCode 1 remote or wireless keypad programming Genie IntelliCode 1 wireless keypadHomelink programming Homelink or Car2U programmingREFERENCE - POWERHEAD & RAIL ASSEMBLED VIEW RÉFÉRENCE - VUE DE LA TÊTE D’ALIMENTATION & DU RAIL ASSEMBLÉPower Cord Rail ConnectorPOWER CORD* TO GROUNDED OUTLET INSTALACIÓN HABITUAL DE UNA PUERTA SECCIONALTYPICAL SUPPORT BRACKET NOT PROVIDED EXTENSION SPRINGTYPICAL ONE PIECE DOOR INSTALLATION AVERTISSEMENTADVERTENCIA POWER CORD* TO 120V GROUNDED OUTLET4 OVERVIEW OF POWERHEAD CONTROLS on powerheadProgramming Overview Buttons5 OVERVIEW - REMOTES AND OPTIONS and holdFIG. 5-1 Remote PURPLEINTELLICODE FEATURES Red = IntelliCode 1 / Green = IntelliCodeUse this If you haveIMPORTANT SAFETY INSTRUCTIONS 6 MAINTENANCE & TROUBLESHOOTING8. SAVE THESE INSTRUCTIONS TRANSMITTER COMPLIANCE STATEMENTROUTINE MONTHLY MAINTENANCE 2. AdjustmentSectional Door One-Piece Door1. Disconnect power to door opener 2. Reconnect power to door openerRESET - OPEN/CLOSE TRAVEL LIMIT DOORIndicator Light wire routingWALL CONSOLE - OVERVIEW Open/Close ButtonObserve all safety warning and precautions CHAIN OR BELT - TENSION ADJUSTMENTREMOTE BATTERY REPLACEMENT ADJUSTMENT GUIDE - SPEED SETTINGS CHANGE SPEED SETTINGPowerhead LEDs Round LED Long LED Speed LevelForce Level ADJUSTMENT GUIDE - FORCE SETTINGSCHANGE FORCE SETTING TROUBLESHOOTING GUIDE - OPERATION TROUBLESHOOTING GUIDE - POWERHEAD LEDs Powerhead LEDPossible Problem SolutionREFERENCE - CIRCUIT WIRING DIAGRAM POWER CORDAVERTISSEMENT ELECTRICAL SHOCKSILENTMAX LIMITED WARRANTY This page left blank This page left blank This page left blank Commande Automatique ForceGuard CARACTÉRISTIQUES DU PORTIER ÉLECTRIQUEConsole murale de série CARACTÉRISTIQUES DE SÉCURITÉTABLE DES MATIÈRES Référence5 Vue densemble des télécommandes et des options Facultatif - installation duelle de console de murIMPORTANTES INSTRUCTIONS D’INSTALLATION linstallation de s a été accomplie commencent iciUne fois lopener lassemblée physique et voir la page suivante1 PROGRAMMATION DES LIMITES ET DE LA FORCE A LIMITE DE COURSE DE FERMETURE DE PORTERÉGLER & VÉRIFIER LES LIMITES ET LA FORCE PROGRAM SETB OUVRIR LA LIMITE DU TRAJET GRAMLE TEST D’INVERSION AU CONTACT La programmation de base du moteur est terminée Le portier électrique est prêt à lusageProgrammation de la télécommande ou du clavier sans fil IntelliCode Programmation HomelinkProgrammation Homelinkou Car2U Genie IntelliCode4 VUE DENSEMBLE DES COMMANDES DE LA TÊTE D’ALIMENTATION FIG. 4-2 Boutons de commandeVue d’ensemble de la programmation BoutonsCERTIFIÉ PAR LA FCC ET IC FIG. 5-1 Télécommandes5 VUE DENSEMBLE - EXTÉRIEURS ET OPTIONS LES CARACTÉRISTIQUES D’INTELLICODE LED rougeIMPORTANTES CONSIGNES DE SÉCURITÉ 6 ENTRETIEN ET DÉPANNAGE8. CONSERVER CES INSTRUCTIONS Porte en sectionFIG. 6-2 2 x 4 sous le centre de louverture de la porte CHANGER LES AMPOULESPORTE Nest pas disponible sur tous les modèlesVERROUILLAGE DU CHARIOT FIG. 6-3 Désactiver du chariotFACULTATIF - INSTALLATION DUELLE DE CONSOLE DE MUR LA CONSOLE DU MUR - VUE DENSEMBLEIndicator Light Bouton pour OUVRIR/FERMERREMPLACEMENT DE LA PILE CHAÎNE OU AJUSTEMENT DE TENSION DE COURROIEObservez tous les avertissement et précautions de sûreté Démontez la puissance de louvreur avant de commencer cette tâcheNiveau de vitesse CHANGEMENT DU RÉGLAGE DE VITESSEGUIDE D’AJUSTEMENT- RÉGLER LA FORCE CHANGEMENT DU RÉGLAGE DE LA FORCENiveau de force DEL de la tête d’alimentationGUIDE DE DÉPANNAGE - FONCTIONNEMENT télécommandeLa télécommande PROBLÈMEGUIDE DE DÉPANNAGE - LES DEL DE LA TÊTE D’ALIMENTATION Problème possibleLa porte ne fonctionne que lorsque ferméeOBLEMAS O FUNCIONAMIEN - OBLEMASP DE UCIÓN SO DE GUÍAR P DE UCIÓN SO DE GUÍAR Ta tu rfuncionaada er te completamega la LED edonda LEDza fue de el Ni o tri eléc cabezal del LEDDE ACIÓN ONFIGU elocidad de el NiOCIDAD VE tarea BANDA O CADENA DE TENSIÓN DE AJUSTEATENCIÓN independienteINSTALACIÓN DOBLE, PARED DE OPCIONAL CONSOLAPUERTA PUERTA4-6 .FIG carro del Liberaciónta pue la de 2-6 FIGTENCIA VE RAD mensual Prueba OIMPORTANTES SEGURIDAD DE INSTRUCCIONES CIONES INSTRU ASARDE OBLEMASATENCIÓN OPCIONES Y REMOTOS CONTROLES - GENERAL DESCRIPCIÓN Remoto Controlsegundos púrpurama Progr BotonesLED de es Colo y Displ LEDProgramación de Homelink HomelinkCar2UoControl remoto IntelliCode la unidad damotorizpúrpura que el LEDLa programación básica de la unidad motorizada está completa LIBEREPROGRAM VEA el LEDProgramación de los controles remotos en la página siguiente PRUEBA DE REVERSA DE CONTACTOB LÍMITE DE RECORRIDO DEL ABRE PUERTAS ESTABLECER LA FUERZA La fuerza seOBSERVE el LED azul intermitente largo En la consola de paredPROGRAMACIÓN DE LÍMITES Y FUERZA A LÍMITERECORRIDO CERRAR LA PUERTAaquí omienzan s de instalación lay física asamblea la a terminado han opener el ez siguiente página la consulteÍNDICE InstalaciónSección encia e rReverse III erie Sada teg i tor vimien m den Detección automática iluminación de SistemaSEGURIDAD DE CIÓN INFORM SÉCURITÉ A À ATIVES RE TIONSL INFORMLP DANGERS DES SOMMAIRE ANTES IMPOR SÛRETÉ DE INSTRUCTIONS200 1SILENTMAX 3643.354.800.1MANUAL ESTE GUARDE GARAJE DE TAS PUE DE /OPERADOR GE GAR DE TE PO-OUVREA