Sterling 30RA010-055 manual AND MANUAL STARTERS cont, Factory Settings For Compressor, Fan, Pump

Page 90

FACTORY SETTINGS FOR COMPRESSOR, FAN, PUMP,

AND MANUAL STARTERS (cont)

 

 

 

OVERLOAD

OVERLOAD

OVERLOAD

OVERLOAD

 

MANUAL

MANUAL

MANUAL STARTER

 

 

 

MANUAL

 

SETTINGS FOR

UNIT

 

 

RELAY (CA1)

RELAY (CA2)

RELAY (CB1)

RELAY (CB2)

STARTER

STARTER

 

VOLTAGE

VOLTAGE

STARTER

 

PUMP OPTIONS

SIZE

SETTING FOR

SETTING FOR

SETTING FOR

SETTING FOR

SETTING

SETTING

 

V-PH-Hz

SERIES

FOR FANS

 

 

(Model Number

30RA

 

 

COMPRESSOR

COMPRESSOR

COMPRESSOR

COMPRESSOR

FC-HS/LS

FOR

FOR CHC

 

 

Position 9)

 

 

 

A1

A2

B1

B2

 

FC-A1/A2

(Heaters)

 

 

 

 

 

 

 

 

 

 

A/F

B/G

C/H

D/J

E/K

 

 

 

 

 

 

 

 

 

 

032

230-3-50

-800

31.4

40.9

49.9

7.6

4.6

2.5

 

4.8

6.1

10.4

380/415-3-50

-900

17.4

23.8

29

4.6

3.7

1.8

2.9

3.7

6.4

 

 

575-3-60

-100

14.6

19.9

22.7

3.6

2.3

1.8

2.5

3.6

6.0

 

380-3-60

-200

22.7

31.7

36.1

5.5

3.5

1.8

3.7

5.4

9.1

 

230-3-60

-400

35.3

44

52.6

9.1

5.8

2.5

6.2

8.9

15.1

035

208/230-3-60

-500

39.2

49

58.4

10.1

7.0

2.5

7.0

9.8

16.7

 

460-3-60

-600

17.5

24.2

28.6

4.6

2.9

1.8

3.1

4.4

7.6

 

230-3-50

-800

49.9

49.9

49.9

7.6

4.6

2.5

4.8

6.1

10.4

 

380/415-3-50

-900

29

29

29

4.6

3.7

1.8

2.9

3.7

6.4

 

575-3-60

-100

19.9

19.9

22.7

3.6

2.3

1.8

2.5

3.6

6.0

 

380-3-60

-200

31.7

31.7

36.1

5.5

3.5

1.8

3.7

5.4

9.1

040

230-3-60

-400

44

44

52.6

9.1

5.8

2.5

6.2

8.9

15.1

 

208/230-3-60

-500

49

49

58.4

10.1

7.0

2.5

7.0

9.8

16.7

 

460-3-60

-600

24.2

24.2

28.6

4.6

2.9

1.8

3.1

4.4

7.6

042

230-3-50

-800

40.9

40.9

40.9

40.9

4.6

2.5

 

4.8

6.1

10.4

380/415-3-50

-900

23.8

23.8

23.8

23.8

3.7

1.8

2.9

3.7

6.4

 

 

575-3-60

-100

15.5

19.9

15.5

19.9

2.3

1.8

2.5

3.6

6.0

 

380-3-60

-200

24.2

31.7

24.2

31.7

3.5

1.8

3.7

5.4

9.1

 

230-3-60

-400

37.1

44

37.1

44

5.8

2.5

6.2

8.9

15.1

045

208/230-3-60

-500

41.2

49

41.2

49

7.0

2.5

7.0

9.8

16.7

 

460-3-60

-600

19.2

24.2

19.2

24.2

2.9

1.8

3.1

4.4

7.6

 

230-3-50

-800

49.9

49.9

49.9

49.9

4.6

2.5

4.8

6.1

10.4

 

380/415-3-50

-900

29

29

29

29

3.7

1.8

2.9

3.7

6.4

 

575-3-60

-100

19.9

19.9

19.9

19.9

2.3

1.8

2.5

3.6

6.0

 

380-3-60

-200

31.7

31.7

31.7

31.7

3.5

1.8

3.7

5.4

9.1

050

230-3-60

-400

44

44

44

44

5.8

2.5

6.2

8.9

15.1

 

208/230-3-60

-500

49

49

49

49

7.0

2.5

7.0

9.8

16.7

 

460-3-60

-600

24.2

24.2

24.2

24.2

2.9

1.8

3.1

4.4

7.6

 

575-3-60

-100

22.7

22.7

22.7

22.7

2.3

1.8

2.5

3.6

6.0

 

380-3-60

-200

36.1

36.1

36.1

36.1

3.5

1.8

3.7

5.4

9.1

055

230-3-60

-400

52.6

52.6

52.6

52.6

5.8

2.5

6.2

8.9

15.1

 

208/230-3-60

-500

58.4

58.4

58.4

58.4

7.0

2.5

7.0

9.8

16.7

 

460-3-60

-600

28.6

28.6

28.6

28.6

2.9

1.8

 

3.1

4.4

7.6

90

Image 90
Contents SAFETY CONSIDERATIONS CONTENTS GENERALSterlco Comfort Network SCN Interface — MAJOR SYSTEM COMPONENTSControl Module Communication Table 1 — Unit SizesTable 2 — Thermistor Designations Table 3 — Status SwitchesTable 5 - SCN Communication Bus Wiring Table 4 - Output RelaysLEGEND FOR FIG. Page Page Fig. 3 — Wiring Schematic 30RA010-018 30RA010-018AQUA SNAPAQUA-SNAPLOW VOLTAGE CONTROL SCHEMATIC Fig. 3 - Wiring Schematic 30RA010-018contSEE NOTE SEE NOTE Fig. 4 - Wiring Schematic 30RA022-030 30RA022-030AQUA SNAPFig. 4 - Wiring Schematic 30RA022-030cont AQUA-SNAPLOW VOLTAGE CONTROL SCHEMATICFig. 5 — Wiring Schematic 30RA032-040 30RA032-040AQUA SNAPFig. 5 — Wiring Schematic 30RA032-040cont AQUA-SNAPLOW VOLTAGE CONTROL SCHEMATICFig. 6 — Wiring Schematic 30RA042-055 30RA042-055AQUA SNAPFig. 6 — Wiring Schematic 30RA042-055cont AQUA-SNAPLOW VOLTAGE CONTROL SCHEMATICREMOTE CONTACT SW1 OFF ENABLE OFF SW2 ON Fig. 7 — Main Base BoardESCAPEENTER MODEFig. 9 — Typical Space Temperature Sensor Wiring Fig. 11 - Energy Management Module CEPL130351100/100 Fig. 12 — Deadband Multiplier Fig. 13 — Operating Envelope for R-22Maneurop CompressorFig. 14 — 30RA Condenser Fan Sequence Cooling Set Point Select Table 8 — Control Methods and Cooling Set Points Service Test See Table 11 — Both main powerand control circuit power must be on Fig. 16 — Scrolling Marquee DisplayOptional Factory-InstalledHydronic Package — •Cooler Pump Control CPC Configuration, OPT1 ON Fig. 17 — Dual Chiller Thermistor Location Table 9 — Marquee Display Menu StructureTable 10 — Run Status Mode and Sub-ModeDirectory SUB-MODE Table 12 - Temperature Mode and Sub-ModeDirectory Table 13 — Pressure Mode and Sub-ModeDirectory Table 14 — Set Point and Sub-ModeDirectoryTable 15 — Inputs Mode and Sub-ModeDirectory KEYPAD Table 16 — Outputs Mode and Sub-ModeDirectorySUB-MODE DISPLAYITEM SUB-MODEKEYPAD DISPLAYITEM SUB-MODEKEYPAD DISPLAYTable 18 — Time Clock Mode and Sub-ModeDirectory PER.3 SUB-MODE Table 20 — Alarms Mode and Sub-ModeDirectory Table 19 — Operating Mode and Sub-ModeDirectoryKEYPAD ENTRY SUB-MODEITEM DISPLAYRSET DISP Table 23 — Operating Modes Table 24 — Example of Reading and Clearing Alarms Table 25A — 4-20mA ResetTable 26B — Configuring Return Temperature Reset Fig. 19 — Outdoor-AirTemperature Reset Fig. 18 — Standard Chilled FluidTemperature Control — No Reset Fig. 20 — Space Temperature ResetFig. 21A — 4- to 20-mADemand Limiting Fig. 21B — Cooling Set Point 4 to 20 mATROUBLESHOOTING Table 27 — Configuring Demand LimitTable 28 — Troubleshooting Recommended that system be filled with an approand fluid tubing Fig. 22 — Component Arrangement — 30RA010-030 FU — Fuse GND — GroundFig. 23 — Component Arrangement — 30RA032-040 FU — Fuse GND — GroundFig. 24 — Component Arrangement — 30RA042-055 FU — Fuse GND — GroundNOTES LEGEND Table 29 — Alarm and Alert Codes Table 29 - Alarm and Alert Codes cont Table 29 — Alarm and Alert Codes cont ALARMTable 29 — Alarm and Alert Codes cont ALARMTable 29 — Alarm and Alert Codes cont ALARMTable 30 - Unit Torque Specification SERVICECompressor Replacement Refer to Fig Electronic ComponentsFig. 29 — Compressor Location — 30RA010-030 Fig. 28 — Compressor WiringFig. 27 — Typical Compressor Mounting — All Sizes Fig. 30 — Compressor Location — 30RA032-055Condenser Section and Coils Table 31 - Oil ChargeFig. 32 — Condenser-FanMounting Fig. 31 — 30RA Access PanelsCheck Refrigerant Feed Components Fig. 33 — Condenser-FanPosition Standard FanCompressor and Unit Protective Devices Table 32 — Factory Settings, High-PressureSwitch Fixed Check Unit SafetiesCOOLER FREEZE-UPPROTECTION TEMP TEMP For Thermistor T10 For Thermistor T10 Main Base Board, J8 Connector Fig. 35 — Fluid-SideTemperature Sensors T1 and T2Fig. 36 — Thermistor Connections to PROGRAMMING Mode Table 37 - Fault Codes •P50: FAULT HISTORY — Last 8 faults•P51: SOFTWARE version PARAMETERS Table 39 — Replacement Modules PRE-START-UP MAINTENANCEMinimum Loop Volume System CheckOperating Limitations OPERATION SEQUENCE Table 41 — Temperature Limits forStandard 30RA Units CIRCADIO Circuit A Discrete Inputs/Outputs APPENDIX ASCN Tables A_UNIT General Unit Parameters CIRCA_AN Circuit A Analog ParametersCIRCBDIO Circuit B Discrete Inputs/Outputs CIRCB_AN Circuit B Analog ParametersOPTIONS Unit Parameters DUALCHIL Dual Chiller Configuration Settings ALARMDEF Alarm Definition TableDISPLAY Marquee Display SETUP BRODEFS Broadcast POC Definition TableOPTIONS1 Options 1 Configuration OPTIONS2 Options 2 ConfigurationSCHEDOVR Timed Override Setup RESETCON Temperature Reset and Demand LimitSETPOINT ALARMS: Maintenance Display UNITMAINTENANCE CURRMODS: Maintenance Display DUALCHIL: Maintenance DisplayLEARNFNS Maintenance Display LOADFACT: Maintenance DisplayPM-COIL:Maintenance Display PM-PUMP:Maintenance DisplayPM-STRN Maintenance Display RUNTEST: Maintenance Display STRTHOUR Maintenance Display TESTMODE: Maintenance DisplayVERSIONS: Maintenance Display WSMDEFME: Maintenance Display FACTORY SETTINGS FOR COMPRESSOR, FAN, PUMP APPENDIX BAND MANUAL STARTERS AND MANUAL STARTERS cont FACTORY SETTINGS FOR COMPRESSOR, FAN, PUMPAPPENDIX C DataPort, DataLink, BAClink Object DefinitionOPTIONS SETPOINTII. Preliminary Equipment Check START-UPCHECKLIST FOR 30RA LIQUID CHILLERRemove and use for Job File I.Project Information Design InformationIII. Unit Start-Up Start and Operate Machine. Complete the FollowingCL-3 Record Software Versions MODE — RUN STATUS COMMENTSCL-4 UNIT Configuration Settings OPTIONS1 Options ConfigurationIII.Unit Start-Upcont III.Unit Start-Upcont OPTIONS2 Options ConfigurationRSET Reset Configuration Settings CL-6SETPOINT SLCT Setpoint and Ramp Load ConfigurationIII.Unit Start-Upcont CL-7Service Test Mode and Sub-ModeDirectory III.Unit Start-Upcont