Sterling
30RA010-055
manual
Sub-Mode, Keypad Entry, Display, Item Expansion, Comments
Troubleshooting
Error codes
Alarm
Compressor Wiring
Maintenance
OPTIONS1 Options Configuration
A — 4-20mA Reset
30RA Access Panels
DISPLAY Marquee Display SETUP
Main Base Board, J8 Connector
Page 38
Page 37
Page 39
Image 38
Page 37
Page 39
Contents
SAFETY CONSIDERATIONS
CONTENTS
GENERAL
Sterlco Comfort Network SCN Interface —
MAJOR SYSTEM COMPONENTS
Control Module Communication
Table 1 — Unit Sizes
Table 2 — Thermistor Designations
Table 3 — Status Switches
Table 5 - SCN Communication Bus Wiring
Table 4 - Output Relays
LEGEND FOR FIG.
Page
Page
Fig. 3 — Wiring Schematic 30RA010-018
30RA010-018AQUA SNAP
SEE NOTE SEE NOTE
AQUA-SNAPLOW VOLTAGE CONTROL SCHEMATIC
Fig. 3 - Wiring Schematic 30RA010-018cont
Fig. 4 - Wiring Schematic 30RA022-030
30RA022-030AQUA SNAP
Fig. 4 - Wiring Schematic 30RA022-030cont
AQUA-SNAPLOW VOLTAGE CONTROL SCHEMATIC
Fig. 5 — Wiring Schematic 30RA032-040
30RA032-040AQUA SNAP
Fig. 5 — Wiring Schematic 30RA032-040cont
AQUA-SNAPLOW VOLTAGE CONTROL SCHEMATIC
Fig. 6 — Wiring Schematic 30RA042-055
30RA042-055AQUA SNAP
Fig. 6 — Wiring Schematic 30RA042-055cont
AQUA-SNAPLOW VOLTAGE CONTROL SCHEMATIC
REMOTE CONTACT SW1 OFF ENABLE OFF SW2 ON
Fig. 7 — Main Base Board
ESCAPEENTER
MODE
Fig. 9 — Typical Space Temperature Sensor Wiring
Fig. 11 - Energy Management Module
CEPL130351
100/100
Fig. 12 — Deadband Multiplier
Fig. 14 — 30RA Condenser Fan Sequence
Fig. 13 — Operating Envelope for
R-22Maneurop Compressor
Cooling Set Point Select
Table 8 — Control Methods and Cooling Set Points
Service Test See Table 11 — Both main power
and control circuit power must be on
Fig. 16 — Scrolling Marquee Display
Optional Factory-InstalledHydronic Package —
•Cooler Pump Control CPC Configuration, OPT1 ON
Fig. 17 — Dual Chiller Thermistor Location
Table 9 — Marquee Display Menu Structure
Table 10 — Run Status Mode and Sub-ModeDirectory
SUB-MODE
Table 12 - Temperature Mode and Sub-ModeDirectory
Table 15 — Inputs Mode and Sub-ModeDirectory
Table 13 — Pressure Mode and Sub-ModeDirectory
Table 14 — Set Point and Sub-ModeDirectory
KEYPAD
Table 16 — Outputs Mode and Sub-ModeDirectory
SUB-MODE
DISPLAY
ITEM
SUB-MODE
KEYPAD
DISPLAY
ITEM
SUB-MODE
KEYPAD
DISPLAY
Table 18 — Time Clock Mode and Sub-ModeDirectory
PER.3
SUB-MODE
Table 20 — Alarms Mode and Sub-ModeDirectory
Table 19 — Operating Mode and Sub-ModeDirectory
KEYPAD ENTRY
SUB-MODE
ITEM
DISPLAY
RSET
DISP
Table 23 — Operating Modes
Table 24 — Example of Reading and Clearing Alarms
Table 25A — 4-20mA Reset
Table 26B — Configuring Return Temperature Reset
Fig. 19 — Outdoor-AirTemperature Reset
Fig. 18 — Standard Chilled Fluid
Temperature Control — No Reset
Fig. 20 — Space Temperature Reset
Fig. 21A — 4- to 20-mADemand Limiting
Fig. 21B — Cooling Set Point 4 to 20 mA
TROUBLESHOOTING
Table 27 — Configuring Demand Limit
and fluid tubing
Table 28 — Troubleshooting
Recommended that system be filled with an appro
Fig. 22 — Component Arrangement — 30RA010-030
FU — Fuse GND — Ground
Fig. 23 — Component Arrangement — 30RA032-040
FU — Fuse GND — Ground
Fig. 24 — Component Arrangement — 30RA042-055
FU — Fuse GND — Ground
NOTES
LEGEND
Table 29 — Alarm and Alert Codes
Table 29 - Alarm and Alert Codes cont
Table 29 — Alarm and Alert Codes cont
ALARM
Table 29 — Alarm and Alert Codes cont
ALARM
Table 29 — Alarm and Alert Codes cont
ALARM
Table 30 - Unit Torque Specification
SERVICE
Compressor Replacement Refer to Fig
Electronic Components
Fig. 29 — Compressor Location — 30RA010-030
Fig. 28 — Compressor Wiring
Fig. 27 — Typical Compressor Mounting — All Sizes
Fig. 30 — Compressor Location — 30RA032-055
Condenser Section and Coils
Table 31 - Oil Charge
Fig. 32 — Condenser-FanMounting
Fig. 31 — 30RA Access Panels
Check Refrigerant Feed Components
Fig. 33 — Condenser-FanPosition Standard Fan
Compressor and Unit Protective Devices
Table 32 — Factory Settings, High-Pressure
Switch Fixed
Check Unit Safeties
COOLER FREEZE-UPPROTECTION
TEMP
TEMP
For Thermistor T10
For Thermistor T10
Fig. 36 — Thermistor Connections to
Main Base Board, J8 Connector
Fig. 35 — Fluid-SideTemperature Sensors T1 and T2
PROGRAMMING
Mode
•P51: SOFTWARE version
Table 37 - Fault Codes
•P50: FAULT HISTORY — Last 8 faults
PARAMETERS
Table 39 — Replacement Modules
PRE-START-UP
MAINTENANCE
Minimum Loop Volume
System Check
Operating Limitations
Standard 30RA Units
OPERATION SEQUENCE
Table 41 — Temperature Limits for
CIRCADIO Circuit A Discrete Inputs/Outputs
APPENDIX A
SCN Tables A_UNIT General Unit Parameters
CIRCA_AN Circuit A Analog Parameters
OPTIONS Unit Parameters
CIRCBDIO Circuit B Discrete Inputs/Outputs
CIRCB_AN Circuit B Analog Parameters
DUALCHIL Dual Chiller Configuration Settings
ALARMDEF Alarm Definition Table
DISPLAY Marquee Display SETUP
BRODEFS Broadcast POC Definition Table
OPTIONS1 Options 1 Configuration
OPTIONS2 Options 2 Configuration
SETPOINT
SCHEDOVR Timed Override Setup
RESETCON Temperature Reset and Demand Limit
MAINTENANCE
ALARMS: Maintenance Display
UNIT
CURRMODS: Maintenance Display
DUALCHIL: Maintenance Display
LEARNFNS Maintenance Display
LOADFACT: Maintenance Display
PM-STRN Maintenance Display
PM-COIL:Maintenance Display
PM-PUMP:Maintenance Display
RUNTEST: Maintenance Display
VERSIONS: Maintenance Display
STRTHOUR Maintenance Display
TESTMODE: Maintenance Display
WSMDEFME: Maintenance Display
AND MANUAL STARTERS
FACTORY SETTINGS FOR COMPRESSOR, FAN, PUMP
APPENDIX B
AND MANUAL STARTERS cont
FACTORY SETTINGS FOR COMPRESSOR, FAN, PUMP
APPENDIX C
DataPort, DataLink, BAClink Object Definition
OPTIONS
SETPOINT
II. Preliminary Equipment Check
START-UPCHECKLIST FOR 30RA LIQUID CHILLER
Remove and use for Job File I.Project Information
Design Information
III. Unit Start-Up
Start and Operate Machine. Complete the Following
CL-3
CL-4
Record Software Versions MODE — RUN STATUS
COMMENTS
III.Unit Start-Upcont
UNIT Configuration Settings
OPTIONS1 Options Configuration
III.Unit Start-Upcont
OPTIONS2 Options Configuration
RSET Reset Configuration Settings
CL-6
SETPOINT
SLCT Setpoint and Ramp Load Configuration
III.Unit Start-Upcont
CL-7
Service Test Mode and Sub-ModeDirectory
III.Unit Start-Upcont
Related pages
Troubleshooting for Maytag W10274254C
Specifications for JVC SP-UXB70
Menu Error indicator Volume -/+ for Philips bClever SV1
Grilling Chart for Hamilton Beach 840135600
You supply your receipt to show when you bought it for Kenwood FP910 series
Installing the Camera Driver for WIN 98 SE Users for Concord Camera 5040
Parts List for Char-Broil 06601295
Language code list for Panasonic DVD-S29
Where can I locate the
neutral safety switch
in the JD 5083E?
Top
Page
Image
Contents