Sterling
30RA010-055
manual
30RA022-030AQUA SNAP, Wiring Schematic 30RA022-030
Troubleshooting
Error codes
Alarm
Compressor Wiring
Maintenance
OPTIONS1 Options Configuration
A — 4-20mA Reset
30RA Access Panels
DISPLAY Marquee Display SETUP
Main Base Board, J8 Connector
Page 10
30RA022-030
AQUA SNAP
Fig. 4 — Wiring Schematic
30RA022-030
10
Page 9
Page 11
Image 10
Page 9
Page 11
Contents
SAFETY CONSIDERATIONS
CONTENTS
GENERAL
Sterlco Comfort Network SCN Interface —
MAJOR SYSTEM COMPONENTS
Control Module Communication
Table 1 — Unit Sizes
Table 2 — Thermistor Designations
Table 3 — Status Switches
Table 5 - SCN Communication Bus Wiring
Table 4 - Output Relays
LEGEND FOR FIG.
Page
Page
Fig. 3 — Wiring Schematic 30RA010-018
30RA010-018AQUA SNAP
Fig. 3 - Wiring Schematic 30RA010-018cont
AQUA-SNAPLOW VOLTAGE CONTROL SCHEMATIC
SEE NOTE SEE NOTE
Fig. 4 - Wiring Schematic 30RA022-030
30RA022-030AQUA SNAP
Fig. 4 - Wiring Schematic 30RA022-030cont
AQUA-SNAPLOW VOLTAGE CONTROL SCHEMATIC
Fig. 5 — Wiring Schematic 30RA032-040
30RA032-040AQUA SNAP
Fig. 5 — Wiring Schematic 30RA032-040cont
AQUA-SNAPLOW VOLTAGE CONTROL SCHEMATIC
Fig. 6 — Wiring Schematic 30RA042-055
30RA042-055AQUA SNAP
Fig. 6 — Wiring Schematic 30RA042-055cont
AQUA-SNAPLOW VOLTAGE CONTROL SCHEMATIC
REMOTE CONTACT SW1 OFF ENABLE OFF SW2 ON
Fig. 7 — Main Base Board
ESCAPEENTER
MODE
Fig. 9 — Typical Space Temperature Sensor Wiring
Fig. 11 - Energy Management Module
CEPL130351
100/100
Fig. 12 — Deadband Multiplier
R-22Maneurop Compressor
Fig. 13 — Operating Envelope for
Fig. 14 — 30RA Condenser Fan Sequence
Cooling Set Point Select
Table 8 — Control Methods and Cooling Set Points
Service Test See Table 11 — Both main power
and control circuit power must be on
Fig. 16 — Scrolling Marquee Display
Optional Factory-InstalledHydronic Package —
•Cooler Pump Control CPC Configuration, OPT1 ON
Fig. 17 — Dual Chiller Thermistor Location
Table 9 — Marquee Display Menu Structure
Table 10 — Run Status Mode and Sub-ModeDirectory
SUB-MODE
Table 12 - Temperature Mode and Sub-ModeDirectory
Table 14 — Set Point and Sub-ModeDirectory
Table 13 — Pressure Mode and Sub-ModeDirectory
Table 15 — Inputs Mode and Sub-ModeDirectory
KEYPAD
Table 16 — Outputs Mode and Sub-ModeDirectory
SUB-MODE
DISPLAY
ITEM
SUB-MODE
KEYPAD
DISPLAY
ITEM
SUB-MODE
KEYPAD
DISPLAY
Table 18 — Time Clock Mode and Sub-ModeDirectory
PER.3
SUB-MODE
Table 20 — Alarms Mode and Sub-ModeDirectory
Table 19 — Operating Mode and Sub-ModeDirectory
KEYPAD ENTRY
SUB-MODE
ITEM
DISPLAY
RSET
DISP
Table 23 — Operating Modes
Table 24 — Example of Reading and Clearing Alarms
Table 25A — 4-20mA Reset
Table 26B — Configuring Return Temperature Reset
Fig. 19 — Outdoor-AirTemperature Reset
Fig. 18 — Standard Chilled Fluid
Temperature Control — No Reset
Fig. 20 — Space Temperature Reset
Fig. 21A — 4- to 20-mADemand Limiting
Fig. 21B — Cooling Set Point 4 to 20 mA
TROUBLESHOOTING
Table 27 — Configuring Demand Limit
Recommended that system be filled with an appro
Table 28 — Troubleshooting
and fluid tubing
Fig. 22 — Component Arrangement — 30RA010-030
FU — Fuse GND — Ground
Fig. 23 — Component Arrangement — 30RA032-040
FU — Fuse GND — Ground
Fig. 24 — Component Arrangement — 30RA042-055
FU — Fuse GND — Ground
NOTES
LEGEND
Table 29 — Alarm and Alert Codes
Table 29 - Alarm and Alert Codes cont
Table 29 — Alarm and Alert Codes cont
ALARM
Table 29 — Alarm and Alert Codes cont
ALARM
Table 29 — Alarm and Alert Codes cont
ALARM
Table 30 - Unit Torque Specification
SERVICE
Compressor Replacement Refer to Fig
Electronic Components
Fig. 29 — Compressor Location — 30RA010-030
Fig. 28 — Compressor Wiring
Fig. 27 — Typical Compressor Mounting — All Sizes
Fig. 30 — Compressor Location — 30RA032-055
Condenser Section and Coils
Table 31 - Oil Charge
Fig. 32 — Condenser-FanMounting
Fig. 31 — 30RA Access Panels
Check Refrigerant Feed Components
Fig. 33 — Condenser-FanPosition Standard Fan
Compressor and Unit Protective Devices
Table 32 — Factory Settings, High-Pressure
Switch Fixed
Check Unit Safeties
COOLER FREEZE-UPPROTECTION
TEMP
TEMP
For Thermistor T10
For Thermistor T10
Fig. 35 — Fluid-SideTemperature Sensors T1 and T2
Main Base Board, J8 Connector
Fig. 36 — Thermistor Connections to
PROGRAMMING
Mode
•P50: FAULT HISTORY — Last 8 faults
Table 37 - Fault Codes
•P51: SOFTWARE version
PARAMETERS
Table 39 — Replacement Modules
PRE-START-UP
MAINTENANCE
Minimum Loop Volume
System Check
Operating Limitations
Table 41 — Temperature Limits for
OPERATION SEQUENCE
Standard 30RA Units
CIRCADIO Circuit A Discrete Inputs/Outputs
APPENDIX A
SCN Tables A_UNIT General Unit Parameters
CIRCA_AN Circuit A Analog Parameters
CIRCB_AN Circuit B Analog Parameters
CIRCBDIO Circuit B Discrete Inputs/Outputs
OPTIONS Unit Parameters
DUALCHIL Dual Chiller Configuration Settings
ALARMDEF Alarm Definition Table
DISPLAY Marquee Display SETUP
BRODEFS Broadcast POC Definition Table
OPTIONS1 Options 1 Configuration
OPTIONS2 Options 2 Configuration
RESETCON Temperature Reset and Demand Limit
SCHEDOVR Timed Override Setup
SETPOINT
UNIT
ALARMS: Maintenance Display
MAINTENANCE
CURRMODS: Maintenance Display
DUALCHIL: Maintenance Display
LEARNFNS Maintenance Display
LOADFACT: Maintenance Display
PM-PUMP:Maintenance Display
PM-COIL:Maintenance Display
PM-STRN Maintenance Display
RUNTEST: Maintenance Display
TESTMODE: Maintenance Display
STRTHOUR Maintenance Display
VERSIONS: Maintenance Display
WSMDEFME: Maintenance Display
APPENDIX B
FACTORY SETTINGS FOR COMPRESSOR, FAN, PUMP
AND MANUAL STARTERS
AND MANUAL STARTERS cont
FACTORY SETTINGS FOR COMPRESSOR, FAN, PUMP
APPENDIX C
DataPort, DataLink, BAClink Object Definition
OPTIONS
SETPOINT
II. Preliminary Equipment Check
START-UPCHECKLIST FOR 30RA LIQUID CHILLER
Remove and use for Job File I.Project Information
Design Information
III. Unit Start-Up
Start and Operate Machine. Complete the Following
CL-3
COMMENTS
Record Software Versions MODE — RUN STATUS
CL-4
OPTIONS1 Options Configuration
UNIT Configuration Settings
III.Unit Start-Upcont
III.Unit Start-Upcont
OPTIONS2 Options Configuration
RSET Reset Configuration Settings
CL-6
SETPOINT
SLCT Setpoint and Ramp Load Configuration
III.Unit Start-Upcont
CL-7
Service Test Mode and Sub-ModeDirectory
III.Unit Start-Upcont
Related pages
All Diagram page
Water Flow Diagram for Samsung WA400PJHDWR
Program Chart for Samsung DV5008JEW/XSG
System chart for Samsung L310W
DR4300 Circular Chart Recorder Step Action/Result Graphic for Honeywell DR4300
Schematic of Tiger classical spi set-up for Hobie Tiger
Diagramme des fonctions for Toshiba PDR-M4
Diagrama DEL Compresor for DeVillbiss Air Power Company MGP-SL10120H-2A
Wiring Diagrams for United States Stove 1600
HPL-MC012 Schematic for Texas Instruments TAS5102
Where to buy replacement parts including
AY28X079
for Trane air conditioners?
Top
Page
Image
Contents