Luxury Whirlpool Bath
Troubleshooting Procedures
| PROBLEM | PROBABLE CAUSES | REMEDY |
|
|
|
|
| Pump/motor does not start | No power to pump/motor | Reset GFCI |
| Pump/motor not plugged in | Insert plug securely into outlet | |
|
| ||
|
|
| Ensure the control panel is conencted to control box |
|
| Pump/motor faulty | Contact Jacuzzi Luxury Bath @ |
|
|
|
|
| Pump/motor operates but no fully adjustable jets are | Jets are closed | Open jets by rotating |
| functioning | Suction cover/strainer may be clogged | With the motor turned OFF, remove the suction cover/ |
|
| ||
|
|
| strainer and remove any debris. Replace the suction |
|
|
| cover before operating |
|
|
|
|
| Pump/motor operates but air is not injected into the | Air valves are closed | Open air control valves |
| water |
|
|
|
|
|
|
| Water leakage from pump unions | Overtightened, | Loosen unions , check and reseat |
|
| seated, undertightened | been pinched out of shape, replace (refer to number |
|
|
| below). When tightening union nuts, handtighten only. |
|
|
|
|
| Pump/motor shuts off by itself before time elapses | Motor thermal protection has deactivated pump/motor | Let motor cool; thermal protection will reset. Check for |
|
| due to overheating (supply voltage low) | proper ventilation (check supply voltage) |
|
|
|
|
|
| GFCI tripped | Reset GFCI. If it continues to trip, do not use this unit. |
|
|
| Disconnect the unit and have the problem corrected by |
|
|
| a licensed electrician before using. |
|
| Inadequate supply wiring | Consult a licensed electrician to correct the wiring unit. |
| Chromatherapy lights do not operate | Connector has come loose | Contact Jacuzzi Luxury Bath @ |
|
|
|
|
|
|
|
|
If the unit is within the warranty period, contact Jacuzzi Whirlpool Bath Service Support at
English