Galaxy
FLASHING indicates the batteries are being charged.
Table
IMPORTANT!
In addition to BBU failure itself and the charger failure, the subsystem may also light the BBU fault LED when the following occur:
1.The temperature sensor embedded with the charger circuit reports a temperature reading exceeding 45 degree Celsius.
2.The BBU (battery backup unit) has been charged for over 12 hours. The BBU charger will enter a timer fault state.
When the above conditions occur, the charger circuit will enter a
You may correct the faults when receiving a “BBU Thermal Shutdown/Enter
1.Check proper ventilation within the subsystem. You may also check the readings from other sensors within the enclosure. Airflow might have been disrupted by the absence of one or several major modules or the failure of a cooling fan. Once the thermal condition is improved, charging will resume automatically.
2.If a new battery module has been charged for over twelve (12) hours and this event is issued, you may remove and
3.Whenever you
3.2.6PSU Module LED
Each PSU module has one (1) LED just below operational status of the PSU module. Please refer to
the retention screw to indicate the Table
System Monitoring |