Chapter 4: Subsystem Connection and Operation
Data Path Connection |
|
|
|
Host Channel Bandwidth | 1600 MB/s |
|
|
Max. Number of Drives | 24 |
|
|
The onboard hub can be disabled so that individual host ports provide access to individual RAID controllers.
•This is a SAN storage application using two (2) host channels through four
(4) separate FC links from individual RAID controllers.
•Path bypass redundancy is provided externally by a fabric switch.
•Depending on switch port configuration, change your FC
•Access management software can be implemented to direct data flow through an existing host link if one of the data paths fails. The precondition is that an array should also be available through the host ID/LUNs on another host link.
CAUTION!
Figure 3-10: Faulty Connections in a Public Loop
Please DO NOT connect the cascade ports of a single host channel on a RAID controller to two different FC switches. A public loop contains only one FL_port, and hence the second FL_port will become
Subsystem Connection and Operation |