EtherHub 1500 System User’s Guide

The system tests each component one at a time. The corresponding LED will display a blinking light (ON) after test completion to indicate which component failed the test. No light means all the hub components passed the diagnostics.

For EtherHub-16i+, the unit will complete the test cycle even if a problem is detected on any of the components. For EtherHub-16mi+, the unit will complete the test cycle for components 1 to 12 even if a problem is detected. However, if a problem is detected on components 13 or 14, the Alert LED and the corresponding PARTITION/DISABLED LED will immediately blink ON and the testing cycle will not be completed.

Configure Button

On the left front panel is a button labeled Configure. Use this button for the following configuration functions:

Segment Setting

Hub ID Setting

Master Agent Setting (only for EtherHub-16mi+)

Demo (LED display demonstration)

Diagnostics

Reset

Move from one function to the next by using a "long press" on the button. LED indicators will light up depending on the selected system function. Make necessary choices within the current function using a "short press". Then, use a "long press" to effect your choice and move on to the next function. See Using the Configure Button in Chapter 4 for related information.

Φ"Long press" in this User’s Guide means pressing the Configure button for more than 2 seconds and then releasing it. "Short press" means pressing the Configure button and immediately releasing it. Also, if the button is not pressed within 10 seconds, the system returns to normal operation.